Publications by authors named "Julien Chaves-Jacob"

Mass reduction of mechanical systems is a recurrent objective in engineering, which is often reached by removing material from its mechanical parts. However, this material removal leads to a decrease of mechanical performances for the parts, which must be minimized and controlled to avoid a potential system failure. To find a middle-ground between material removing and mechanical performances), material must be kept only in areas where it is necessary, for example using stress-driven material removal methods.

View Article and Find Full Text PDF

Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative functional deficits are reported even after a rehabilitation program. In order to determine the origin of functional deficits of patient suffering from knee osteoarthritis and total knee arthroplasty, we developed a rodent model including a chemically-induced-osteoarthritis and designed a knee prosthesis (Ti6Al4V/PEEK) biomechanically and anatomically adapted to rat knee joint.

View Article and Find Full Text PDF

Nowadays, salt consumption appears to be drastically above the recommended level in industrialized countries. The health consequences of this overconsumption are heavy since high-salt intake induces cardiovascular disease, kidney dysfunction, and stroke. Moreover, harmful interaction may also occur with orthopaedic devices because overconsumption of salt reinforces the corrosive aspect of biological tissues and favors bone resorption process.

View Article and Find Full Text PDF

Despite the worldwide high prevalence of total joint arthroplasty (TJA), life expectancy of prosthesis remains limited by mechanical and chemical constraint which promote wear debris production, surrounding tissues damage and finally prosthesis loosening. Such results could be amplified by neuro-myoelectrostimulation (NMES; widely used to reduce neuromuscular deficits observed following TJA surgery). It was previously described in an in vivo experiment that interactions between NMES and Ti6Al4V implant are deleterious for both implant and surrounding muscles.

View Article and Find Full Text PDF

New fusionless devices are being developed to get over the limits of actual spinal surgical treatment, based on arthrodesis. However, due to their recentness, no standards exist to test and validate those devices, especially concerning the wear. A new tribological first approach to the definition of an in vitro wear protocol to study wear of flexible and sliding spinal devices is presented in this article, and was applied to a new concept.

View Article and Find Full Text PDF

Aim Of The Study: High-salt consumption has been widely described as a risk factor for cardiovascular, renal and bone functions. In the present study, the extent to which high-salt diet could influence Ti6Al4V implant surface characteristic, its adhesion to rat tibial crest, and could modify muscle cell viability of two surrounding muscles, was investigated in vivo. These parameters have also been assessed following a NMES (neuro-myoelectrostimulation) program similar to that currently used in human care following arthroplasty.

View Article and Find Full Text PDF

Electrical currents have deleterious effects on biomedical metallic implants. However, following arthroplasty, neuro-myoelectrostimulation (NMES) is often used in patient rehabilitation. Such a rehabilitation technique could compromise patient recovery through deleterious effects on metallic alloys and biological tissues.

View Article and Find Full Text PDF