Cochlear Implants Int
September 2020
To examine the effects of unilateral cochlear implantation on the balance system for adult patients with bilateral severe to profound sensory neural hearing loss. 7 CI candidates. The function of the sacculus, utricle, and three semi-circular canals (SCCs) was assessed separately using air conduction cervical vestibular evoked myogenic potentials (VEMP), vibration ocular VEMP and the video head impulse test (vHIT) respectively on each side, pre- and post-operatively.
View Article and Find Full Text PDFCochlear Implants Int
January 2013
Objectives: Magnetic resonance imaging (MRI) is a standard part of a cochlear implant assessment in most centres. While there is ample literature on the temporal bone-specific imaging that is required, the role of whole brain imaging has not been as fully studied. We present the first report of the incidence of associated brain abnormalities in the whole cochlear implant population, including adults and consider their significance.
View Article and Find Full Text PDFEfficacy of the SPEAK and ACE coding strategies was compared with that of a new strategy, MP3000™, by 37 European implant centers including 221 subjects. The SPEAK and ACE strategies are based on selection of 8-10 spectral components with the highest levels, while MP3000 is based on the selection of only 4-6 components, with the highest levels relative to an estimate of the spread of masking. The pulse rate per component was fixed.
View Article and Find Full Text PDFElectrical artifacts caused by the cochlear implant (CI) contaminate electroencephalographic (EEG) recordings from implanted individuals and corrupt auditory evoked potentials (AEPs). Independent component analysis (ICA) is efficient in attenuating the electrical CI artifact and AEPs can be successfully reconstructed. However the manual selection of CI artifact related independent components (ICs) obtained with ICA is unsatisfactory, since it contains expert-choices and is time consuming.
View Article and Find Full Text PDFAuditory evoked potentials (AEPs) provide an objective measure of auditory cortical function, but AEPs from cochlear implant (CI) users are contaminated by an electrical artifact. Here, we investigated the effects of electrical artifact attenuation on AEP quality. The ability of independent component analysis (ICA) in attenuating the CI artifact while preserving the AEPs was evaluated.
View Article and Find Full Text PDFThis paper describes the relationship between the scores obtained in the Bamford, Kowal and Bench (BKB) sentence test and the Arthur Boothroyd (AB) word test in quiet for a group of 71 cochlear implant users. Each subject was tested at the same appointment and in the same environment during routine clinical appointments at the South of England Cochlear Implant Centre.Using rationalised arcsine transformation and a linear regression calculation, conversion tables were produced from BKB to AB and from AB to BKB scores.
View Article and Find Full Text PDFThis study attempts to answer the question of whether there is a 'critical age' after which a second contralateral cochlear implant is less likely to provide enough speech perception to be of practical use. The study was not designed to predict factors that determine successful binaural implant use, but to see if there was evidence to help determine the latest age at which the second ear can usefully be implanted, should the first side fail and become unusable.Outcome data, in the form of speech perception test results, were collected from 11 cochlear implant programmes in the UK and one centre in Australia.
View Article and Find Full Text PDFPsychophysiology
January 2008
Little is known about how the auditory cortex adapts to artificial input as provided by a cochlear implant (CI). We report the case of a 71-year-old profoundly deaf man, who has successfully used a unilateral CI for 4 years. Independent component analysis (ICA) of 61-channel EEG recordings could separate CI-related artifacts from auditory-evoked potentials (AEPs), even though it was the perfectly time-locked CI stimulation that caused the AEPs.
View Article and Find Full Text PDF