Publications by authors named "Juliane M Guerreiro-Tanomaru"

Objective: Our purpose was to investigate the physicochemical properties of Bio-C Temp, a bioceramic intracanal medication, and whether its residues remain adhered to the dentine walls after conventional manual irrigation (CMI) or passive ultrasonic irrigation (PUI) in comparison to Calen.

Methods: The pH after 12 hours, 1 day, 3 days, 7 days, 14 days, 21 days and 28 days, and the flow, radiopacity, and the solubility of the medications after immersion for 7 and 30 days in distilled water (dH2O) or phosphate-buffered saline (PBS) solution were evaluated. Filling capacity, and volumetric changes after 14 days were assessed by micro-computed tomography (micro-CT).

View Article and Find Full Text PDF

Context: An acidic hydrogen potential (pH) in an inflammatory condition in the periapical tissues may affect the properties of repair bioceramic cement.

Aims: The aim of this study was to evaluate the effect of pH on the volumetric change of the ready-to-use bioceramic NeoPUTTY (NP) compared to the powder/liquid MTA Repair HP (MTAHP) after immersion in butyric acid (BA, pH 4.1) or phosphate-buffered saline (PBS, pH 7.

View Article and Find Full Text PDF

This study aimed to evaluate the effect of in vitro immersion solutions or an in vivo method on volumetric change of bioceramic root repair materials: Bio-C Repair (BCR, Angelus, Londrina, PR, Brazil) and Biodentine (BIO, Septodont, Saint-Maur-des-Fossés, France) compared to IRM (Dentsply Sirona, York, Pennsylvania, USA) by using microcomputed tomography (µCT) assessment. Tubes of polyvinyl chloride (PVC, 4 mm of length x 1.3 mm of inside diameter, n = 7) were filled with the materials for volumetric analysis in µCT.

View Article and Find Full Text PDF

This study assessed the physicochemical and antibiofilm properties of white mineral trioxide aggregate (MTA) associated with 1 or 2% of farnesol. Setting time was evaluated based on ISO 6876/2012. Radiopacity was evaluated by radiographic analysis.

View Article and Find Full Text PDF

This study evaluated the effect of ultrasonic agitation on the filling capacity of ready-to-use calcium silicate-based sealer Bio-C Sealer (BCS, Angelus, Paraná, Brazil) or powder-liquid BioRoot RCS (BR, Septodont, Saint-Maur-des-Fossés, France) using curved artificial canals by micro-computed tomography (micro-CT). Additionally, flow (mm) and flow area (mm2) were evaluated for both materials. Acrylic resin main canal (60° curvature and 5 mm radius, with 3 lateral canals in the cervical, middle, and apical thirds) were prepared up to size 40/.

View Article and Find Full Text PDF

This study evaluated the biocompatibility, bioactivity, porosity, and sealer/dentin interface of Sealer Plus BC (SP), Bio-C Sealer (BIOC), TotalFill BC Sealer (TF), and AH Plus (AHP). Dentin tubes filled with the sealers and empty tubes (control group) were implanted in the subcutaneous tissue of rats for different periods (n = 6 per group/period). Number of inflammatory cells (ICs), capsule thickness, von Kossa reaction, interleukin-6 (IL-6) and osteocalcin (OCN) were evaluated.

View Article and Find Full Text PDF
Article Synopsis
  • * Mandibular molar root canals were filled with either calcium silicate sealer (Bio-C Sealer) or epoxy resin (AH Plus), and it was found that AH Plus left more residual filling material after retreatment.
  • * The supplementary protocols, especially using PDL 50/.01 and XP-endo Finisher, improved the removal of filling material in the apical third of curved root canals without causing transportation issues.
View Article and Find Full Text PDF

Objective: To evaluate the solubility and the volumetric and morphological alterations of bioceramic filling material (Bio-CP) for primary teeth.

Materials And Methods: Bio-CP, Calen thickened with zinc oxide (Calen-ZO), and with zinc oxide eugenol (ZOE) were placed in 1- or 2-mm-diameter polyethylene tubes and immersed in water or phosphate-buffered saline (PBS) for 30 days. The solubility (mass loss) was assessed using methodology modified from ISO 6876.

View Article and Find Full Text PDF

Acidic pH can modify the properties of repair cements. In this study, volumetric change and solubility of the ready-to-use bioceramic repair cement Bio-C Repair (BCR, Angelus, Londrina, PR, Brazil) were evaluated after immersion in phosphate-buffered saline (PBS) (pH 7.0) or butyric acid (pH 4.

View Article and Find Full Text PDF

Aim: To evaluate the inflammatory reaction and the ability to induce mineralization activity of a new repair material, NeoPUTTY (NPutty; NuSmile, USA), in comparison with Bio-C Repair (BC; Angelus, Brazil) and MTA Repair HP (MTA HP; Angelus, Brazil).

Methodology: Polyethylene tubes were filled with materials or kept empty (control group, CG) and implanted in subcutaneous tissue of rats for 7, 15, 30, and 60 days (n = 6/group). Capsule thickness, number of inflammatory cells (ICs), fibroblasts, collagen content, and von Kossa analysis were performed.

View Article and Find Full Text PDF

Intracanal medications are used in endodontic treatment due to their antibacterial activity and ability to induce the periapical repair. Among the intracanal medications, the Calen (CAL; SS. White, Brazil) is a calcium hydroxide-based medication that provides an alkaline pH and releases calcium, exerting an antimicrobial activity.

View Article and Find Full Text PDF

Introduction: The aim of this study was to evaluate the effectiveness of the XP-endo Finisher R (XPFR; FKG Dentaire, La Chaux-de-Fonds, Switzerland) or the Flatsonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, SP, Brazil) in removing remaining filling material after the retreatment of flattened root canals using micro-computed tomographic imaging.

Methods: Twenty-four flattened distal root canals of mandibular molars with a buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with Reciproc Blue (RB) R40 (VDW GmbH, Munich, Germany) and filled using the Tagger hybrid technique. All canals were retreated with RB R40, and apical enlargement was performed with RB R50 (VDW GmbH).

View Article and Find Full Text PDF

This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05.

View Article and Find Full Text PDF

The aim of this study was to evaluate root canal preparation with nickel titanium rotary instruments and complementary preparation with ultrasonic tip in curved canals of mandibular molars with isthmus. Twenty-eight mesial roots of mandibular molars with curvature between 20° and 40° and presence of isthmus throughout the entire extension of the root canals were prepared using ProDesign Logic CM (PDL) up to size 40.05, or HyFlex EDM (HFEDM) up to size 40.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of radiopacifier calcium tungstate and manipulation with distilled water (DW) or liquid with additives (LA) on calcium silicate clinker Angelus (CL) properties, compared with MTA (Angelus, Brazil) and MTA Repair HP (MTAHP, Angelus, Brazil). The physicochemical properties, cellular viability and bioactivity were evaluated. ANOVA/Tukey and Bonferroni tests were performed (α = 0.

View Article and Find Full Text PDF

Objectives: This study is to evaluate biocompatibility, bioactive potential, porosity, and dentin/material interface of Bio-C Repair (BIOC-R), MTA Repair HP (MTAHP), and Intermediate Restorative Material (IRM).

Materials And Methods: Dentin tubes were implanted into subcutaneous of rats for 7, 15, 30, and 60 days. Thickness of capsules, number of inflammatory cells (ICs), interleukin-6 (IL-6), osteocalcin (OCN), and von Kossa were evaluated.

View Article and Find Full Text PDF

The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests.

View Article and Find Full Text PDF

Modified formulations of calcium silicate repair materials with additives have been developed to enhance handling, consistency, biocompatibility and bioactivity. Considering the relevance of osteoblastic cell response to mineralized tissue repair, human osteoblastic cells (Saos-2 cells overexpressing BMP-2) were exposed to mineral trioxide aggregate (MTA) (with calcium tungstate - CaWO4), MTA HP Repair, Bio-C Repair and Bio-C Pulpo. Cell viability was assessed by 3-(4,5-dimethylthiazol)-2,5-diphenyltetrazolium bromide (MTT) and neutral red (NR), and cell death, by flow cytometry.

View Article and Find Full Text PDF

Aim: To evaluate whether the bioceramic materials Bio-C Pulpo (Bio-C, Angelus) and mineral trioxide aggregate (MTA) Repair HP (MTA-HP, Angelus) induce fibroblast proliferation and release of interleukin-10 (IL-10), an anti-inflammatory cytokine, stimulating connective tissue remodelling. The tissue response of Bio-C and MTA-HP was compared with the White MTA (WMTA; Angelus) since studies have demonstrated that WMTA induces tissue repair.

Methodology: Bio-C, MTA-HP and WMTA were inserted into polyethylene tubes and implanted in the subcutaneous tissue of Holtzman rats for 7, 15, 30 and 60 days.

View Article and Find Full Text PDF

Aim: To evaluate the tissue reaction of a tricalcium silicate-based repair material associated with 30% calcium tungstate (TCS + CaWO ) in comparison to Bio-C Repair (Bio-C; Angelus) and to MTA Repair HP (MTA HP; Angelus).

Methodology: Polyethylene tubes filled with one of the materials or left empty (control group, CG) were implanted into the subcutaneous tissues of rats for 7, 15, 30 and 60 days (n = 32/group). The capsule thickness, number of inflammatory cells, collagen content, interleukin-6 (IL-6), osteocalcin (OCN), von Kossa reaction and analysis under polarized light were evaluated.

View Article and Find Full Text PDF

Objective:  This study assessed the influence of additional apical preparation on material removal during retreatment of curved root canals filled with different sealers.

Materials And Methods:  Twelve mesial roots of mandibular molars with two separate canals and curvature between 25 and 35 degrees were selected. The working length was established 1-mm short of the apical foramen, and all the root canals were prepared using ProDesign R (PDR) 25/0.

View Article and Find Full Text PDF

As the biocompatibility and bioactive potential of repair materials are desired characteristics in dentistry, the tissue response of Bio-C Pulpo, a bioceramic material launched on the marked by Angelus (Brazil), was compared with Biodentine (Septodont, France) and White MTA (WMTA; Angelus, Brazil). In 32 rats, 148 polyethylene tubes filled with Bio-C Pulpo, Biodentine or WMTA, and empty (CG, control group) were implanted into subcutaneous tissues for 7, 15, 30, and 60 days. The capsule thickness, numerical density of inflammatory cells (IC) and fibroblasts (Fb), amount of collagen, immunohistochemistry detection of interleukin-6 (IL-6) and osteocalcin (OCN), von Kossa and analysis under polarized light were performed.

View Article and Find Full Text PDF

Objective: To assess the effects of different peracetic acid (PAA) formulations on smear layer (SL) removal, dentine erosion, cytotoxicity, and antibiofilm activity.

Methodology: SL removal and dentine erosion were assessed using 90 premolars, distributed into six groups, according to final irrigation: PAA formulations (1% Sigma, 1% Bacterend OX, 1% Arposept, and 0.09-0.

View Article and Find Full Text PDF

Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements.

Materials And Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) ( = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 µm.

View Article and Find Full Text PDF

Our purpose was to evaluate the biocompatibility and hepatotoxicity of a new bioceramic intracanal medicament, Bio-C Temp (BIO). The biological properties of BIO were compared with calcium hydroxide-based intracanal medicament (Calen; CAL), used as gold pattern. Polyethylene tubes filled with BIO or CAL, and empty tubes (control group, CG) were implanted into subcutaneous tissue of rats.

View Article and Find Full Text PDF