Publications by authors named "Julia Fernandez-Pastor"

Unexplained cardiac arrest (UCA) can be caused by low-penetrance genetic disorders. The aim of this cross-sectional study is to assess the usefulness of a new diagnostic protocol: Thirty-five patients were recruited from 9 Spanish centers. Electrocardiogram, echocardiogram, and coronary catheterization were used to rule out electrical or structural heart disease in all subjects.

View Article and Find Full Text PDF

Aims: Hypertrophic cardiomyopathy is one of the main causes of sudden death in young people. Recent clinical practice guidelines include a risk prediction model for sudden death (HCM Risk-SCD), which facilitates the decision of whether to implant a defibrillator. The aim of our study was to ascertain the percentage of events in our series of primary prevention implantable cardioverter-defibrillator recipients with hypertrophic cardiomyopathy and whether HCM Risk-SCD predicts the onset of arrhythmic events.

View Article and Find Full Text PDF

Background: Clinical practice guidelines recommend ad hoc screening of diabetes in patients admitted for macrovascular disease; however, these recommendations are rarely followed in real practice. This study was undertaken to assess whether impaired glucose metabolism, newly diagnosed after percutaneous coronary intervention (PCI) or known diabetes, provides prognostic information.

Methods: We studied 374 patients who underwent PCI.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) using the new Accutrak delivery system (Medtronic, Inc.).

View Article and Find Full Text PDF

Introduction And Objectives: Although changes in atrioventricular conduction frequently occur after percutaneous implantation of an aortic valve prosthesis, little is known about the mechanisms involved or how these changes progress. We investigated ECG abnormalities and predictors of pacemaker need after percutaneous implantation of the CoreValve® aortic valve prosthesis.

Methods: Between April 2008 and October 2009, 65 patients with symptomatic severe aortic stenosis received a CoreValve® prosthesis.

View Article and Find Full Text PDF

Aims: Cardiac resynchronization therapy (CRT) improves survival and quality of life in advanced heart failure (HF). Although mitral regurgitation (MR) reduction has been reported, its presence has been associated with non-response to CRT. This study was undertaken to assess the potential role of significant mitral regurgitation (SMR) persistence after CRT on clinical outcome, major arrhythmic events, and echocardiographic response in the mid-long term.

View Article and Find Full Text PDF

Aims: The combined use of an automatic defibrillator in resynchronization therapy for primary prevention in patients with idiopathic dilated cardiomyopathy is controversial.

Methods And Results: We assessed a series of 46 patients (61 +/- 10 years, 64% male) with idiopathic dilated cardiomyopathy undergoing resynchronization therapy combined with a defibrillator in primary prevention and the potential relationship between baseline characteristics and the onset of ventricular arrhythmic events. Of the 46 patients included, eight (17%) presented episodes of ventricular tachycardia/fibrillation during follow-up (19 +/- 12 months).

View Article and Find Full Text PDF

The aim of this study was to compare the effects of cardiac resynchronization therapy on left ventricular function and reverse remodeling in patients in sinus rhythm with the effects in patients with atrial fibrillation who have not undergone atrioventricular node ablation. Echocardiographic and clinical parameters were evaluated at baseline and after 6 months of cardiac resynchronization therapy in 55 patients: 15 had atrial fibrillation and 40 were in sinus rhythm. Device programming was similar in the 2 groups, as were the reductions in QRS interval and echocardiographic measures of asynchrony observed after implantation.

View Article and Find Full Text PDF