Blowout fractures are common midfacial fractures in which one or several of the bones of orbital vault break. This is usually caused by a direct trauma to the eye with a blunt object such as a fist. Fracturing of the fragile orbital bones can lead to changes in the orbital volume, which may cause enophthalmos, diplopia, and impaired facial aesthetics.
View Article and Find Full Text PDFObjectives: The aim of this study was to identify cone-beam computed tomography (CBCT) protocols that offer an optimal balance between effective dose (ED) and 3D model for orthognathic virtual surgery planning, using CT as a reference, and to assess whether such protocols can be defined based on technical image quality metrics.
Methods: Eleven CBCT (VISO G7, Planmeca Oy, Helsinki, Finland) scan protocols were selected out of 32 candidate protocols, based on ED and technical image quality measurements. Next, an anthropomorphic RANDO SK150 phantom was scanned using these 11 CBCT protocols and 2 CT scanners for bone quantity assessments.
J Oral Maxillofac Surg
July 2024
Background: Patients sustaining maxillofacial fractures are at risk for associated injuries (AIs) to other body regions. The incidence of AIs is reported to be from 20 to 35%. AIs may be life-threatening and play a key role in considering first-line management at the emergency department, as well as planning the definitive treatment of maxillofacial fractures.
View Article and Find Full Text PDFIntroduction: Gut microbiome-derived nanoparticles, known as bacterial extracellular vesicles (bEVs), have garnered interest as promising tools for studying the link between the gut microbiome and human health. The diverse composition of bEVs, including their proteins, mRNAs, metabolites, and lipids, makes them useful for investigating diseases such as cancer. However, conventional approaches for studying gut microbiome composition alone may not be accurate in deciphering host-gut microbiome communication.
View Article and Find Full Text PDFThis article presents the outcomes of prosthetic oral rehabilitation using CAD/CAM telescopic bar overdentures in patients with oral cancer ( = 3), severe facial trauma ( = 2), or various syndromes ( = 1), all suffering from severe tissue deficits and requiring complex and comprehensive oral rehabilitation. The aim was to assess the durability and functionality of implant-retained prosthetic structures, ensuring easy oral hygiene and minimizing specialized follow-up needs. The data for this study were sourced from a retrospective cohort at Helsinki University Hospital.
View Article and Find Full Text PDFThis patient series reports the outcomes of CAD/CAM prosthetic reconstructions in patients with cleft lip and palate (n = 9, aged 27 to 76) who have experienced significant failure with conventional restorative and fixed prosthodontic treatments. The objective of the protocol is to establish a functional and patient-friendly prosthetic structure for individuals with unilateral/bilateral cleft lip and palate (UCLP/BCLP) while minimising the requirement for specialised follow-up care in the cleft unit. The study data were obtained from a retrospective cohort at Helsinki University Hospital.
View Article and Find Full Text PDFAim: The aim of this study was to retrospectively investigate the risk factors and their association on bimaxillary osteotomies to be able to improve patient selection and bimaxillary osteotomy planning.
Material And Methods: Patients treated with a bimaxillary osteotomy were included in the study. The complications were collected retrospectively from the patient data records.
Facial asymmetry is common in unilateral clefts. Since virtual surgical planning (VSP) is becoming more common and automated segmentation is utilized more often, the position and asymmetry of the orbits can affect the design outcome. The aim of this study is to evaluate whether non-syndromic unilateral cleft lip and palate (UCLP) patients requiring orthognathic surgery have asymmetry of the bony orbits.
View Article and Find Full Text PDFThe aim of this study was to evaluate and compare the biofilm formation properties of common pathogens associated with implant-related infections on two different implant material types. Bacterial strains tested in this study were , , , and . Implant materials tested and compared were PLA Resorb × polymer of Poly DL-lactide (PDLLA) comprising 50% poly-L-lactic acid and 50% poly-D-lactic acid) and Ti grade 2 (tooled with a Planmeca CAD-CAM milling device).
View Article and Find Full Text PDFBackground: When postoperative multi-slice computed tomography (MSCT) imaging of patients with craniosynostosis is used, it is usually performed a few days after surgery in a radiology department. This requires additional anesthesia for the patient. Recently, intraoperative mobile cone-beam CT (CBCT) devices have gained popularity for orthopedic and neurosurgical procedures, which allows postoperative CT imaging in the operating room.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
February 2023
Purpose: The use of virtual surgical planning and patient-specific saw and drill guides combined with customized osteosynthesis is becoming a gold standard in orthognathic surgery. The aim of this study is to report preliminary results of the use of virtual surgical planning and the wafer-free PSI technique in cleft patients.
Materials And Methods: Patient-specific saw and drill guides combined with milled patient-specific 3D titanium alloy implants were used in reposition and fixation in Le Fort I osteotomy of 12 cleft patients.
This study investigated two of the most commonly used CAD-CAM materials for patient-specific reconstruction in craniomaxillofacial surgery. The aim of this study was to access the biofilm formation of , , , and on titanium and PEEK medical implant materials. Two titanium specimens (titanium grade 2 tooled with a Planmeca CAD-CAM milling device and titanium grade 5 tooled with a computer-aided design direct metal laser sintering device (CAD-DMLS)) and one PEEK specimen tooled with a Planmeca CAD-CAM milling device were studied.
View Article and Find Full Text PDFThe aim of this study was to assess the biofilm formation of , , , and on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (), TiAlV grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (), TiAlV grade 23 as it comes from a CAD-CAM milling device (), and CAD-DMLS TiGrade 5 polished with an abrasive disc (). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement.
View Article and Find Full Text PDFBackground/aim: Handgrip strength has been used to evaluate the potential of elderly patients to survive different medical conditions or procedures, or to predict the nutritional status and length of hospitalization. The aim of this study was to evaluate the use of handgrip strength as a predictor of the length of hospitalization and need for prolonged intensive care in patients with oral malignancies requiring surgical resection and simultaneous primary reconstruction with microvascular free flap.
Patients And Methods: This is a retrospective study of 37 head and neck carcinoma patients operated between 2012 and 2014 who had undergone a handgrip force test.
We report the use of a three-dimensional virtual surgical planning technique including both fusion and superimposition to obtain harmony and symmetry of the face in an 18-year-old woman suffering from cherubism. The treatment contained several threedimensional techniques that allowed precise planning and a predictable surgical outcome. The reduction plasty was successful, and the postoperative healing was uneventful.
View Article and Find Full Text PDFPurpose: The aim of this study was to analyze the clinical outcome of the use of botulinum toxin type A (BTX) intramuscular injections to the head and neck, particularly the masticatory muscles of patients with temporomandibular disorder (TMD).
Methods: The medical records of all patients who had received intramuscular BTX injections between 2005 and 2018 at Päijät- Häme Central Hospital, Lahti, Finland were analyzed retrospectively. Gender, age, previous medical history, number of injections, injection areas, and therapeutic results were collected and analyzed.
The aim of the study is to evaluate clinical methods to obtain a significantly improved fitting of patient specific implants (PSI) in bilateral sagittal split osteotomies and to evaluate the use of electromagnetic navigation as a potential guide for condyle positioning. A prospective study using (1) a solid bite registration index during preoperative computed tomography, (2) critical planning with regard to the condylar rotation, (3) a piezoelectric saw throughout the mandibular osteotomy, and (4) intraoperative navigation to determine the position of the PSIs and the mandibular segments intraoperatively was performed. Ten patients were treated.
View Article and Find Full Text PDFTemporomandibular joint (TMJ) reconstruction with alloplastic prosthesis is a commonly performed procedure, which can be used as a treatment for improving pathologic conditions affecting the TMJ. Depending of the severity of the condition, the patient's ability to eat can be impaired, which in turn can affect their quality of life. Several syndromes can affect the patient's facial features, and some of those also affect TMJ's.
View Article and Find Full Text PDFJ Craniomaxillofac Surg
September 2021
This retrospective study was performed to report the peri- and postoperative complications encountered by patients who underwent Le Fort I osteotomy, as well as predictor variables affecting the risk of complications. Patients who underwent only Le Fort I osteotomy were included in the study. Information on peri- and postoperative complications were collected from the patient data records.
View Article and Find Full Text PDFThe aim of this cross-sectional study is to propose an efficient strategy based on biomarkers adjunct with an interview/questionnaire covering risk factors for periodontitis for the identification of undiagnosed periodontitis by medical professionals. Active matrix metalloproteinase (aMMP)-8 levels in mouthrinse were analyzed by a point-of-care (PoC)/chairside lateral-flow immunotest, and salivary total MMP-8, total MMP-9 and calprotectin levels were analyzed by enzyme-linked immunosorbent assays (ELISAs) and active MMP-9 by gelatin zymography for 149 Greek patients. Patients underwent a full-mouth oral health examination for diagnosis according to the 2018 classification system of periodontal diseases.
View Article and Find Full Text PDFComputer-aided design and manufacturing (CAD-CAM)-based techniques are developing fast in facial reconstruction and osteosynthesis. Patient-specific implant (PSI) production is already sufficiently fast for everyday use and can be utilized even for primary trauma surgery such as orbital floor reconstruction after blowout fracture. Purpose of our study is to retrospectively analyze the 3-dimensional (3D) success of PSI reconstructions of orbital floor fractures in our unit.
View Article and Find Full Text PDFThe aim of this study was to evaluate the surface roughness of fixed prosthodontic materials after polishing or roughening with a stainless steel curette or ultrasonic scaler and to examine the effect of these on adhesion and biofilm accumulation. Thirty specimens (10 × 10 × 3 mm) of zirconia (Zr), pressed lithium disilicate (LDS-Press), milled lithium disilicate glazed (LDS-Glaze), titanium grade V (Ti) and cobalt-chromium (CoCr) were divided into three groups (n = 10) according to surface treatment: polished (C), roughened with stainless steel curette (SC), roughened with ultrasonic scaler (US). Surface roughness values (Sa, Sq) were measured with a spinning disc confocal microscope, and contact angles and surface free energy (SFE) were measured with a contact angle meter.
View Article and Find Full Text PDF