Background: In spring of 2022, an outbreak of monkeypox (mpox) spread worldwide. Here, we describe performance characteristics of monkeypox virus (MPXV)-specific and pan-orthopoxvirus qPCR assays for clinical use.
Methods: We validated probe-based qPCR assays targeting MPXV-specific loci F3L and G2R (genes MPXVgp052/OPG065 and MPXVgp002 and gp190/OPG002, respectively) and a pan-orthopoxvirus assay targeting the E9L locus (MPXVgp057/OPG071).
SARS-CoV-2 variants of concern (VOC) have triggered infection waves. Oral antivirals such as molnupiravir promise to improve disease management, but efficacy against VOC delta was questioned and potency against omicron is unknown. This study evaluates molnupiravir against VOC in human airway epithelium organoids, ferrets, and a lethal Roborovski dwarf hamster model of severe COVID-19-like lung injury.
View Article and Find Full Text PDFArthropods are integral to ecosystem equilibrium, serving as both a food source for insectivores and supporting plant reproduction. Members of the family in the order are frequently found in RNA sequenced from arthropods, who serve as their hosts. Here we implement a metagenomic deep sequencing approach followed by rapid amplification of cDNA ends (RACE) on viral RNA isolated from wild and captured bat guano in Washington State at two separate time points.
View Article and Find Full Text PDFSARS-CoV-2 variants of concern (VOC) have triggered distinct infection waves in the coronavirus disease 2019 (COVID-19) pandemic, culminating in currently all-time high incidence rates of VOC omicron. Orally available direct-acting antivirals such as molnupiravir promise to improve disease management and limit SARS-CoV-2 spread. However, molnupiravir efficacy against VOC delta was questioned based on clinical trial results and its potency against omicron is unknown.
View Article and Find Full Text PDFSmall-group discussion is a central component of 21st-century biology classrooms. Many factors shape these discussions and thus influence potential learning gains. This study examined how accuracy and idea consideration shaped small-group discussions in undergraduate biology labs (12 groups, M = 42.
View Article and Find Full Text PDFTumors of neuroepithelial tissue represent the largest group of pediatric brain tumors by far and has therefore been divided into several discrete tumor subtypes each corresponding to a specific component of the neuropil. The neuropil contains several subtypes of glial cells, including astrocytes, oligodendrocytes, ependymal cells and modified ependymal cells that form the choroid plexus. This review discusses the imaging aspects of the most common pediatric tumors of neuroepithelial tissue.
View Article and Find Full Text PDFBackground: For moderately emetogenic chemotherapy, palonosetron (PALO) is reported to provide complete control of chemotherapy-induced nausea and vomiting (CINV) in 69% of patients. Prior to August 2009, our gastrointestinal (GI) cancer patients receiving the moderately emetogenic compounds oxaliplatin or irinotecan plus a fluoropyrimidine regimen received ondansetron and dexamethasone orally on day 1 of chemotherapy for CINV prevention. Beginning in August of 2009, ondansetron was replaced by PALO 0.
View Article and Find Full Text PDFBackground: The predictive value of positron emission tomography-computed tomography (PET-CT) in primary staging and response control in patients with esophageal carcinoma (EC) is under discussion. In the present study initial staging and metabolic response of PET-CT was correlated with tumor regression and survival in patients with multimodal treatment of EC.
Methods: The authors conducted a retrospective analysis on a prospective database for 83 patients with EC (42 squamous cell, 39 adenocarcinoma, 2 anaplastic carcinoma) undergoing PET-CT for primary staging.
Objective: The purpose of this article is to prospectively assess the frequency and type of IV injection site complications associated with high-flow power injection of nonionic contrast medium in MDCT.
Subjects And Methods: Contrast-enhanced (300-370 mg iodine/mL) MDCT examinations with high flow rates (up to 8 mL/s) using automatic CT injectors were performed according to standardized MDCT protocols. The location, type, and size (16-24 gauge) of IV catheters and volumes, iodine concentration, and flow rates of contrast medium were documented.
The purpose of these guidelines is to offer the nuclear medicine and the appropriate interdisciplinary team a framework for performing and reporting positron emission tomography (PET) and the combination with computed tomography (PET/CT) in children with malignant diseases mainly using the radiopharmaceutical 18F-fluorodeoxy-glucose (FDG). These guidelines are based on the recent guidelines of the Paediatric Committee of the European Association of Nuclear Medicine (EANM) (57) and have been translated and adapted to the current conditions in Germany. The adaptation of CT-parameters using PET/CT in children is covered in a more detailed way than in the EANM guideline taking into account that in Germany already a good portion of PET examinations is performed using an integrated PET/CT-scanner.
View Article and Find Full Text PDFAim: This study had three major objectives: 1.) to record the number of concordant (both in PET and CT) pathological lesions in different body regions/organs, 2.) to evaluate the image quality and 3.
View Article and Find Full Text PDFPurpose: To determine regional and global left ventricular (LV) functional parameters and to perform segmental wall thickness (SWT) and motion (WM) analysis of dual-source CT (DSCT) with optimized temporal resolution versus MRI.
Materials And Methods: 30 patients with known or suspected CAD, non-obstructive HCM, DCM, ARVCM, Fallot Tetralogy, cardiac sarcoidosis and cardiac metastasis underwent DSCT and MRI. The DSCT and MR images were evaluated: end-systolic (ESV), end-diastolic LV (EDV) volumes, stroke volume (SV), ejection fraction (EF), and myocardial mass (MM) as well as LV wall thickening and segmental WM applying the AHA model were obtained and statistically analyzed.
The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s.
View Article and Find Full Text PDFPurpose: Determination of an adequate scan delay for routine abdominal 64-slice CT examinations with body weight-adapted contrast application.
Materials And Methods: 57 patients underwent abdominal CT with a 64-slice scanner. The contrast material was adapted to patient body weight.
The aim of this study was to assess the performance of a motion-map algorithm that automatically determines optimal reconstruction windows for dual-source coronary CT angiography. In datasets from 50 consecutive patients, optimal systolic and diastolic reconstruction windows were determined using the motion-map algorithm. For manual determination of the optimal reconstruction window, datasets were reconstructed in 5% steps throughout the RR interval.
View Article and Find Full Text PDFObjective: It is mandatory to teach antiseptic skills to staff who use contrast agent injectors. The purpose of this study was to evaluate in an experimental setting and in clinical routine the risk of microbiologic contamination of the syringes of injectors used to administer contrast agent and saline solution for MDCT.
Materials And Methods: Microbiologic contamination of CT injector syringes over multiple uses for several injections was investigated in an experimental setup simulating the clinical setting.
Purpose: To assess the accuracy of liver lesion measurement using automated measurement and segmentation software depending on the vascularization level.
Materials And Methods: Arterial and portal venous phase multislice CT (MSCT) was performed for 58 patients. 94 liver lesions were evaluated and classified according to vascularity (hypervascular: 13 hepatocellular carcinomas, 20 hemangiomas; hypovascular: 31 metastases, 3 lymphomas, 4 abscesses; liquid: 23 cysts).
Eur J Nucl Med Mol Imaging
August 2008
Objective: The purpose of these guidelines is to offer to the nuclear medicine team a framework that could prove helpful in daily practice. These guidelines contain information related to the indications, acquisition, processing and interpretation of (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) in paediatric oncology. The Oncology Committee of the European Association of Nuclear Medicine (EANM) has published excellent procedure guidelines on tumour imaging with (18)F-FDG PET (Bombardieri et al.
View Article and Find Full Text PDFPurpose: This prospective single-centre phase II trial assessed the diagnostic impact of (18)F-FDG PET-CT in the evaluation of solid pancreatic lesions (phi >or= 10 mm) compared to endosonography (EUS), endoscopic retrograde cholangio-pancreatography (ERCP) with intraductal ultrasound (IDUS), abdominal ultrasound (US) and histopathological reference.
Methods: Forty-six patients (32 men/14 women, phi 61.7 years) with suspected pancreatic neoplasms underwent PET-CT with contrast-enhanced biphasic multi-detector CT of the upper abdomen followed by a diagnostic work-up with EUS, ERCP with IDUS and US within 3 weeks.
The purpose was to compare global left-ventricular (LV) function parameters measured with cine MRI with results from multiphase dual-source CT (DSCT) using 10 and 20 reconstruction phases. Twenty-eight patients with suspected or known CAD underwent DSCT coronary angiography. LV end-diastolic (EDV), end-systolic (ESV) and stroke volumes (SV), and ejection fraction (EF) were determined using LV segmentation and selection of specific phases from DSCT image sets reconstructed either at 5% or 10% steps through the R-R interval.
View Article and Find Full Text PDFAim: This study evaluated a MDCT protocol for contrast-enhanced 16-channel PET-CT with regard to scan range and duration of a whole-body (18)F-FDG PET-CT examination, the occurrence of contrast-material induced artefacts and quantitative assessment of CT attenuation.
Patients, Methods: 205 patients (51.9+/-12.