Publications by authors named "Judith J Dasselaar"

Background And Purpose: Studies have shown the potential of cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (oART) for prostate cancer patients in a simulation environment. The aim of this study was to evaluate the feasibility of the clinical implementation of CBCT-guided oART for prostate cancer patients.

Materials And Methods: Between February and July 2020, eleven prostate cancer patients were treated with CBCT-guided oART using a fractionation scheme of 20 × 3 Gy to the prostate and 20 × 2.

View Article and Find Full Text PDF

Background: Intradialytic hypotension (IDH) is considered one of the most frequent complications of haemodialysis with an estimated prevalence of 20-50 %, but studies investigating its exact prevalence are scarce. A complicating factor is that several definitions of IDH are used. The goal of this study was, to assess the prevalence of IDH, primarily in reference to the European Best Practice Guideline (EBPG) on haemodynamic instability: A decrease in systolic blood pressure (SBP) ≥20 mmHg or in mean arterial pressure (MAP) ≥10 mmHg associated with a clinical event and the need for nursing intervention.

View Article and Find Full Text PDF

Background: Patients with thrice-weekly hemodialysis have higher predialysis weights and ultrafiltration rates at the first compared with subsequent dialysis sessions of the week. We hypothesized that these variations in weight and ultrafiltration rate are associated with a systematic difference in blood pressure.

Study Design: Observational study.

View Article and Find Full Text PDF

The cardiac stress imposed by hemodialysis may differ from that induced by pharmacologic agents used for myocardial perfusion imaging-based stress testing. With repetitive intradialytic [(13)N]ammonia positron emission tomography, we showed that standard hemodialysis had an acute adverse effect on cardiac perfusion and left ventricular function that was not detected by standard diagnostic adenosine stress testing.

View Article and Find Full Text PDF

Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume.

View Article and Find Full Text PDF

Background: Whereas haemodialysis (HD) is lifesaving by replacement of renal function, there are data to suggest that the HD procedure itself may contribute to the high cardiac risk in dialysis patients. The HD procedure is associated with an increased risk of sudden death, and there is accumulating evidence that HD can elicit myocardial ischaemia. In this study, we evaluated the effect of HD on global and regional myocardial blood flow (MBF) and left ventricular (LV) function in non-diabetic, non-cardiac compromised patients.

View Article and Find Full Text PDF

The monitoring of relative blood volume changes (DeltaRBV) has been advocated for the prevention of hemodialysis (HD) hypotension. Stand-alone devices (Crit-Line) or devices incorporated into the HD apparatus (blood volume monitor [BVM], Hemoscan) are widely used for this purpose. Comparisons between devices are scarce.

View Article and Find Full Text PDF

Background: Measurements of relative blood volume changes (DeltaRBV) during hemodialysis (HD) are based on hemoconcentration and assume uniform mixing of erythrocytes and plasma throughout the circulation. However, whole-body hematocrit (Ht) is lower than systemic Ht. During HD, a change in the ratio between whole-body to systemic Ht (F cell ratio) is likely to occur as a result of a net shift of low Ht blood from the microcirculation to the macrocirculation.

View Article and Find Full Text PDF

Monitoring of relative blood volume changes (DeltaRBV) has been propagated for the prevention of hemodialysis hypotension. Although the influence of ultrafiltration volume on DeltaRBV is well-known, there is no mention in the literature that DeltaRBV results should be interpreted differently for the first, second, or third hemodialysis session of the week. To elucidate whether DeltaRBV and its derivative, DeltaRBV normalized for ultrafiltration volume (DeltaRBV/ultrafiltration ratio), vary systematically over the week, we separately analyzed these parameters for the first, second, and third hemodialysis session of the week in 13 chronic hemodialysis patients over a 17-week period.

View Article and Find Full Text PDF

In hypertensive hemodialysis (HD) patients, dry weight reduction to normalize blood pressure (BP) often results in increased frequency of HD hypotension. Because HD with blood volume tracking (BVT) has been shown to improve intra-HD hemodynamic stability, we performed a prospective, randomized study to test whether BVT is more effective than standard hemodialysis (SHD) in the management of hypertension by dry weight reduction. After a run-in period of 4 weeks on SHD, 28 patients were randomly assigned for a 12-week treatment period with either SHD (n = 14) or BVT (n = 14).

View Article and Find Full Text PDF

Achieving an optimal post-hemodialysis hydration status may be difficult because objective criteria for dry weight are lacking. Both relative blood volume changes (DeltaRBV) at the end of hemodialysis and DeltaRBV normalized for ultrafiltration volume (DeltaRBV/UF ratio) have been reported to indicate post-hemodialysis volume status. A parameter for volume status should not be influenced by variations in ultrafiltration volume.

View Article and Find Full Text PDF

Automatic feedback systems have been designed to control relative blood volume changes during hemodialysis (HD) as hypovolemia plays a major role in the development of dialysis hypotension. Of these systems, one is based on the concept of blood volume tracking (BVT). BVT has been shown to improve intra-HD hemodynamic stability.

View Article and Find Full Text PDF