Background: Second generation cryoballoon (CB-A) ablation is highly effective in achieving pulmonary vein (PV) isolation and freedom from atrial fibrillation (AF). However, the ideal freezing strategy is still under debate. Our objective was to investigate the efficacy and outcome between different freezing strategies used with the CB-A in a multicenter, matched population.
View Article and Find Full Text PDFIntroduction: Second-generation cryoballoon (CB-Adv) ablation is highly effective in achieving pulmonary vein isolation (PVI) with promising mid-term clinical outcome. However, the ideal freezing strategy is still under debate. The aim of this study was to assess the efficacy of a single 3-minute approach compared to the conventional 4-minute plus bonus application using CB-Adv.
View Article and Find Full Text PDFAims: Prolonged P-wave duration and dispersion are universally accepted noninvasive markers for atrial electrical remodeling. Our aim was to analyze P-wave indices as predictors of atrial fibrillation recurrence after pulmonary vein isolation in patients with normal left atrial size.
Methods: From January 2008 to December 2011, 426 patients with drug-resistant symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation as an index procedure by conventional radiofrequency or cryoballoon ablation in our center.
The aim of this study was to compare the results of pulmonary vein isolation using conventional irrigated radiofrequency (RF) approach versus the cryoballoon (CB) ablation. From January 2008 to December 2011, a total of 426 patients with drug-resistant symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation as the index procedure by conventional manual RF or CB ablation at our center. A final population of 396 patients was considered for analysis and divided into 2 groups: conventional RF ablation (n = 260) and CB ablation (n = 136).
View Article and Find Full Text PDFBackground: The novel cryoballoon Advance (CB-A) has proven to achieve significantly lower temperatures and faster pulmonary vein isolation (PVI) times in comparison with the first-generation device. Although acutely very effective, to the best of our knowledge, data on mid-term clinical follow-up is lacking.
Aims: The aim of the study was to analyse the freedom from recurrence of atrial fibrillation (AF) on a 1-year follow-up period, in a series of consecutive patients having undergone PVI with the CB-A for paroxysmal AF (PAF).
Background: The second-generation cryoballoon (CB-A) (Arctic Front Advance, Cryocath, Medtronic, MN, USA) might significantly improve procedural outcome with respect to the first-generation balloon. These technological improvements might also question the current recommendation of the need a 4-min freeze to achieve durable pulmonary vein isolation (PVI).
Objective: The main aim of the study was to analyze the procedural efficacy of a 3-min freeze-thaw cycles with the CB-A balloon in the terms of rates of acute PVI and 6-month outcome.