Introduction: Woven bone, a heterogeneous and temporary tissue in bone regeneration, is remodeled by osteoblastic and osteoclastic activity and shaped by mechanical stress to restore healthy tissue properties. Characterizing this tissue at different length scales is crucial for developing micromechanical models that optimize mechanical parameters, thereby controlling regeneration and preventing non-unions.
Methods: This study examines the temporal evolution of the mechanical properties of bone distraction callus using nanoindentation, ash analysis, micro-CT for trabecular microarchitecture, and Raman spectroscopy for mineral quality.
Background: 3D-printed bioceramic scaffolds have gained popularity due to their controlled microarchitecture and their proven biocompatibility. However, their high brittleness makes their surgical implementation complex for weight-bearing bone treatments. Thus, they would require difficult-to-instrument rigid internal fixations that limit a rigorous evaluation of the regeneration progress through the analysis of mechanic-structural parameters.
View Article and Find Full Text PDFCallus tissue exhibits a viscoelastic behavior that has a strong influence on the distribution of stresses and their evolution with time and, thus, it can affect tissue differentiation during distraction procedures. For this reason, a deep knowledge of that viscoelastic behavior can be very useful to improve current protocols of bone distraction and bone transport. Monitoring stress relaxation of the callus during distraction osteogenesis allows characterizing its viscoelastic behavior.
View Article and Find Full Text PDFCollagen is a ubiquitous protein present in regenerating bone tissues that experiences multiple biological phenomena during distraction osteogenesis until the deposition of phosphate crystals. This work combines fluorescence techniques and mathematical modeling to shed light on the mechano-structural processes behind the maturation and accommodation-to-mineralization of the callus tissue. Ovine metatarsal bone calluses were analyzed through confocal images at different stages of the early distraction osteogenesis process, quantifying the fiber orientation distribution and mean intensity as fiber density measure.
View Article and Find Full Text PDFBone lengthening and bone transport are regeneration processes that commonly rely on distraction osteogenesis, a widely accepted surgical procedure to deal with numerous bony pathologies. Despite the extensive study in the literature of the influence of biomechanical factors, a lack of knowledge about their mechanobiological differences prevents a clinical particularization. Bone lengthening treatments were performed on sheep metatarsus by reproducing the surgical and biomechanical protocol of previous bone transport experiments.
View Article and Find Full Text PDFFor the monitoring of bone regeneration processes, the instrumentation of the fixation is an increasingly common technique to indirectly measure the evolution of bone formation instead of ex vivo measurements or traditional in vivo techniques, such as X-ray or visual review. A versatile instrumented external fixator capable of adapting to multiple bone regeneration processes was designed, as well as a wireless acquisition system for the data collection. The design and implementation of the overall architecture of such a system is described in this work, including the hardware, firmware, and mechanical components.
View Article and Find Full Text PDFBone lengthening is a bone regeneration technique with multiple clinical applications. One of the most common complications of this treatment is the lack of adaptation of the surrounding soft tissue to their extension. A better understanding of the mechanobiology of the tissues involved in distraction osteogenesis would allow better control of the clinical cases.
View Article and Find Full Text PDFIn silico models of distraction osteogenesis and fracture healing usually assume constant mechanical properties for the new bone tissue generated. In addition, these models do not always account for the porosity of the woven bone and its evolution. In this study, finite element analyses based on computed tomography (CT) are used to predict the stiffness of the callus until 69 weeks after surgery using 15 CT images obtained at different stages of an experiment on bone transport, technique in which distraction osteogenesis is used to correct bone defects.
View Article and Find Full Text PDFIntroduction: Bone transport appears to be a solution for segmental bone defects; specifically, the "docking site" is where the transported segment meets the target segment at the end of the process. A lack of its consolidation is one of the major causes of failure for this technique. Many studies have been performed in order to enhance the consolidation of the docking site, but histological changes occurring in it remain unknown.
View Article and Find Full Text PDFWoven tissue is mainly present in the bone callus, formed very rapidly either after a fracture or in distraction processes. This high formation speed is probably responsible for its disorganized microstructure and this, in turn, for its low stiffness. Nonetheless, the singular volumetric composition of this tissue may also play a key role in its mechanical properties.
View Article and Find Full Text PDFIntroduction: Bone transport (BT) for segmentary bone defects is a well-known technique as it enables correction with new bone formation, which is similar to the previous bone. Despite the high number of experimental studies of distraction osteogenesis in bone lengthening, the types of ossification and histological changes that occur in the regenerate of the bone transport process remain controversial.
Objective: The aim of this study is to provide the complete evolution of tissues and the types of ossification in the regenerate during the different phases of bone formation after BT until the end of the remodelling period.
J Mech Behav Biomed Mater
August 2016
Bone transport studies have measured the forces related to bone segment distraction (Brunner et al., 1994; Hyodo et al., 1996).
View Article and Find Full Text PDF