Publications by authors named "Juan Jose Puente"

Objectives: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution.

View Article and Find Full Text PDF

Background: Faecal occult blood test (FOBT) has demonstrated effectiveness in colorectal cancer (CRC) screening. Faecal calprotectin (FC) has proven efficient for evaluating activity in inflammatory bowel disease (IBD), but its value in CRC detection is less established. Most symptomatic patients have benign pathologies, but still undergo colonoscopy in many settings.

View Article and Find Full Text PDF

Objectives: The stability of the analytes most commonly used in routine clinical practice has been the subject of intensive research, with varying and even conflicting results. Such is the case of alanine aminotransferase (ALT). The purpose of this study was to determine the stability of serum ALT according to different variables.

View Article and Find Full Text PDF

Soria, M, Ansón, M, Lou-Bonafonte, JM, Andrés-Otero, MJ, Puente, JJ, and Escanero, J. Fat oxidation rate as a function of plasma lipid and hormone response in endurance athletes. J Strength Cond Res 34(1): 104-113, 2020-Plasma lipid changes during incremental exercise are not well known.

View Article and Find Full Text PDF

Background: The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function.

View Article and Find Full Text PDF

Background: Preanalytical variables, such as sample collection, handling and transport, may affect patient results. Preanalytical phase quality monitoring should be established in order to minimize laboratory errors and improve patient safety.

Methods: A retrospective study (2001-2013) of the results obtained through the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) External quality assessment (preanalytical phase) was performed to summarize data regarding the main factors affecting preanalytical phase quality.

View Article and Find Full Text PDF