Publications by authors named "Juan Carlos Prados Frutos"

Article Synopsis
  • A study using finite element analysis was conducted on a new intramedullary implant for correcting claw-hammer toe deformity via proximal interphalangeal joint arthrodesis, which affects 20% of people.
  • The research compared two implant orientations (neutral implant and a 10° angled implant) on a virtual model of a patient’s foot during the toe-off phase of walking, analyzing mechanical stress distributions against a non-surgical foot model.
  • Results showed that the neutral implant significantly reduced tensile and compressive stresses at the proximal phalanx compared to the non-surgical model, while the angled implant increased stress levels, suggesting it could lead to implant failure and is not recommended for use.
View Article and Find Full Text PDF

The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups ( = 20/group): (1) Group Imp 11.

View Article and Find Full Text PDF

Background: The goal of this in vitro study was to compare three different surfaces: two types of implant surfaces commercially available ([a] smooth/machined and [b] acid-treated surface) (c) anodized surface. Discs were manufactured with commercially pure titanium (CP) grade IV, which were subsequently analyzed by scanning microscopy and fibroblastic and osteoblastic cell cultures.

Methods: Ninety-nine discs (5 × 2 mm) were manufactured in titanium grade IV and received different surface treatments: (i) Mach group: machined; (ii) AA group: double acid etch; and (iii) AN group: anodizing treatment.

View Article and Find Full Text PDF

Objectives: Micromotion between a dental implant and abutment can adversely affect clinical performance and compromise successful osseointegration by creating a bacterial harbor, enabling screw loosening, and imparting disruptive lateral forces on the cortical bone. Thus, the aim of the present study was to measure the abutment stability evolution using resonance frequency analysis (RFA) in vivo at four different times (baseline, 3, 4, and 12 months), and compare these data obtained with the RFA measured after mechanical cycling (in vitro) corresponding to the proposed times in numbers of cycles.

Methods: To evaluate the abutment stability, RFA was performed in 70 sets of implant/abutment (IA) with a total of 54 patients (31 women, 23 men).

View Article and Find Full Text PDF

To investigate the reliability of panoramic dental images to detect calcified carotid atheroma, electronic databases (PubMed, IEEE/Xplore and Embase) were searched. Outcomes included cerebrovascular disease events, cardiovascular disease events, patient previous diseases, and combined endpoints. Risk of bias was evaluated using the Newcastle-Ottawa Scale.

View Article and Find Full Text PDF

(1) Background: contact between indigenous and European populations has often resulted in changes in oral health attributed to the introduction of sucrose. Most studies are per tooth over considerable periods and with few ethnological references. (2) Aim: dental epidemiology of 96 autochthonous frozen bodies from Yakutia between the early 17th century and the late 19th century; comparisons with historical texts and ethnographic data.

View Article and Find Full Text PDF

The aim of this study was to assess the long-term clinical behavior of straight implants in comparison with intentionally tilted dental implants (ITDI) supporting fixed restorations in partial or total edentulous arches, analyzing implant survival and success rates, complications, and marginal bone loss (MBL) after >5 years of function. An electronic search was conducted in five electronic databases (MEDLINE/Pubmed, Embase, Web of Science, Scopus, and Cochrane Central Register of Controlled Trials) supplemented by a manual search. The electronic and manual search identified 1853 articles, of which 8 articles were selected for analysis.

View Article and Find Full Text PDF

Background: Halitosis of oral origin is very common in the general population. Due to their antimicrobial properties, chlorhexidine-based products are widely used in the management of this condition, but these are associated with reversible side effects. In this study we evaluated the efficacy of Lacer Hali mouthrinse and toothpaste in subjects with intraoral halitosis after several applications under normal conditions of use.

View Article and Find Full Text PDF

This systematic review and meta-analysis set out to assess the clinical behavior of mandibular implant-supported fixed complete dental prostheses (ISFCDP) on three dental implants by analyzing implant and prosthetic survival rates, marginal bone loss, biological/technical complications, and patient-reported outcomes. The review was conducted according to PRISMA guidelines. Electronic searches were conducted in the Medline (PubMed), Web of Science, and Cochrane databases, complimented by a manual search in specialist journals for relevant articles published up to February 2021.

View Article and Find Full Text PDF

Statement Of Problem: The use of reduced platform sets (implants and abutments) can help to control crestal bone loss around implants, which is essential for optimizing esthetics and biomechanical behavior. However, the information available on the fracture resistance of implants with a reduced platform is sparse.

Purpose: The purpose of this in vitro study was to analyze the maximum fracture strength value of implants with different platform designs during quasistatic fatigue, followed by a simulation of different bone levels of cervical insertion.

View Article and Find Full Text PDF

The objective of our in vivo study was to compare the effects of the osteotomy on the thermal alterations, the bone healing and count of polymorphonuclear cells, comparing the drill design (cylindrical or conical) using continuous or intermittent movement. Twelve rabbits were used, which were made four osteotomies (n = 2 per tibia) to simulate the surgical drilling sequence for the installation of a dental implant at 8 mm of length and regular diameter. Four groups were proposed: group G1, cylindrical drill with continuous movement; group G2, cylindrical drill with intermittent movement; group G3, conical drill with continuous movement; and, group G4, conical drill with intermittent movement.

View Article and Find Full Text PDF

Dental caries is the most prevalent dental disease worldwide, and neural networks and artificial intelligence are increasingly being used in the field of dentistry. This systematic review aims to identify the state of the art of neural networks in caries detection and diagnosis. A search was conducted in PubMed, Institute of Electrical and Electronics Engineers (IEEE) Xplore, and ScienceDirect.

View Article and Find Full Text PDF

Bone plays an important role in dental implant treatment success. The goal of this literature review is to analyze the influence of bone definition and finite element parameters on stress in dental implants and bone in numerical studies. A search was conducted of Pubmed, Science Direct and LILACS, and two independent reviewers performed the data extraction.

View Article and Find Full Text PDF

The present in vitro study evaluated a new drill design to improve the temperature control during the osteotomies for dental implant installation, comparing with two drill designs that use conventional external irrigation. Three blocks of synthetic cortical bone were used for osteotomy procedures. Three groups were created: control group 1 (Con1), where a conical multiple drill system with a conventional external irrigation system was used; control group 2 (Con2), where a single bur with a conventional external irrigation system was used; and, test group (Test), where the new single bur (turbo drill) with a new irrigation system was used.

View Article and Find Full Text PDF

The objective of this study was to analyze three-dimensionally the morphological characteristics of the pterygomaxillary region related to pterygoid implants. Volume, height, width and bone density were studied in relation to age, sex and dental status. This retrospective observational study analyzed the CBCT of 52 hemi-maxillas three-dimensionally (females n = 28, males n = 24; dentate = 31, edentulous = 21).

View Article and Find Full Text PDF

Background: The goal of this study was to analyze the stress distribution on two types of extra-short dental implants with 5 mm of length: An internal hexagon (IH) and morse taper connection (MT).

Methods: The three-dimensional model was composed of trabecular and cortical bone, a crown, an extra-short dental implant and their components. An axial load of 150 N was applied and another inclined 30° with the same magnitude.

View Article and Find Full Text PDF

The aim of this study was to estimate the age of subjects from their dental age by showing the different stages of tooth development using the Nolla method in a Spanish population sample considering the gender, age group, and the development of the two dental arches. The sample consisted of 604 orthopantomographs corresponding to Spanish children (male: 302 and female: 302) aged from 4 to 14 years old. The resulting chronological and dental ages were compared using Student's t-test.

View Article and Find Full Text PDF

The aim of this study was to perform an in vivo histological comparative evaluation of bone formation around titanium (machined and treated surface) and zirconia implants. For the present study were used 50 commercially pure titanium implants grade IV, being that 25 implants with a machined surface (TiM group), 25 implants with a treated surface (TiT group) and, 25 implants were manufactured in pure zirconia (Zr group). The implants ( = 20 per group) were installed in the tibia of 10 rabbits.

View Article and Find Full Text PDF

Purpose: The goal of this study was to foresee the fatigue life of two implant connections, evaluate the failure probability with several bone levels, and compare the in vitro test results with finite element results.

Materials And Methods: Mechanical tests were done with 60 implants (Ø3.50 mm), and abutments were used.

View Article and Find Full Text PDF

To evaluate the bending and torsional properties of four nickel-titanium endodontic files, we simulated and compared WaveOne® primary size 25 with 0.07 taper, WaveOne Gold® primary size 25 with 0.07 taper, Reciproc® primary size 25 with 0.

View Article and Find Full Text PDF

The aim of this study was to fully characterize the mechanical behavior of an external hexagonal implant connection (ø3.5 mm, 10-mm length) with an in vitro study, a three-dimensional finite element analysis, and a probabilistic fatigue study. Ten implant-abutment assemblies were randomly divided into two groups, five were subjected to a fracture test to obtain the maximum fracture load, and the remaining were exposed to a fatigue test with 360,000 cycles of 150 ± 10 N.

View Article and Find Full Text PDF

Objectives: The present study aims to compare the drilling protocol effect on osseointegration event in three commercially available titanium dental implants with different drill protocol using a rabbit tibia model.

Materials And Methods: Three different drilling sequences were compared as follows: drilling sequence using a single unique drill of 4.2 mm conical implant (Group 1), drilling sequence using 3 consecutive cylindrical drills for a 4.

View Article and Find Full Text PDF

Background: The aim of this study was to determine the association between facial pattern according to Ricketts cephalometric analysis, and prevalence of third molar agenesis, taking subject age and gender as control variables.

Material And Methods: An epidemiological survey was conducted based on a sample of 224 candidates for orthodontic treatment aged 12 to 24 (n=224). Third molar agenesis was recorded using Ricketts cephalometric analyses of lateral teleradiographs and panoramic radiographs.

View Article and Find Full Text PDF

The aim of this study was to predict the fatigue life of two different connections of a dental implant as in load transfer to bone. Two three-dimensional models were created and assembled. All models were subjected to a natural masticatory force of 118 N in the angle of 75° to the occlusal plane.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the misfit of three different implant-abutment connections before and after cycling load.

Materials And Methods: One hundred twenty dental implants and correspondent prefabricated titanium abutments were used. Three different implant-abutment connections were evaluated: Morse taper (MT group), external hexagon (EH group), and internal hexagon (IH group).

View Article and Find Full Text PDF