Publications by authors named "Juan Carlos Martinez Anton"

Restorers and curators in museums sometimes find it difficult to accurately segment areas of paintings that have been contaminated with other pigments or areas that need to be restored, and work on the painting needs to be carried out with minimum possible damage. It is therefore necessary to develop measurement systems and methods that facilitate this task in the least invasive way possible. The aim of this study was to obtain high-dynamic-range (HDR) spectral reflectance and spatial resolution for Dalí's painting entitled Two Figures (1926) in order to segment a small area of black and white pigment that was affected by the contact transfer of reddish pigment from another painting.

View Article and Find Full Text PDF

Nowadays, fog is still a natural phenomenon that hinders our ability to detect targets, particularly in the field of driving where accidents are increasing. In the literature we find different studies determining the range of visibility, improving the quality of an image, determining the characteristics of fog, etc. In this work we propose the possibility of using a structured lighting system, on which we project the light towards the target, limiting the field lighting.

View Article and Find Full Text PDF

Commercial hyperspectral imaging systems typically use CCD or CMOS sensors. These types of sensors have a limited dynamic range and non-linear response. This means that when evaluating an artwork under uncontrolled lighting conditions and with light and dark areas in the same scene, hyperspectral images with underexposed or saturated areas would be obtained at low or high exposure times, respectively.

View Article and Find Full Text PDF

The absorption coefficient of a material is classically determined by measuring the transmittance of a homogeneous sample contained within flat optical faces and under collimated illumination. For arbitrary shapes this method is impracticable. The characterization of inhomogeneous or randomly distributed samples such as granules, powders or fibers suffers the same problem.

View Article and Find Full Text PDF

The optical absorption coefficient of culture media is critical for the survival analysis of pathogens under optical irradiation. The quality of the results obtained from experiments relies on the optical analysis of the spatial distribution of fluence which also depends on the geometry of the sample. In this contribution, we consider both the geometrical shape and the culture medium's absorption coefficient to evaluate how the spatial distribution of optical radiation affects pathogens/viruses.

View Article and Find Full Text PDF

Optical profilometers based on light reflection may fail at surfaces presenting steep slopes and highly curved features. Missed light, interference and diffraction at steps, peaks and valleys are some of the reasons. Consequently, blind areas or profile artifacts may be observed when using common reflection micro-optical profilometers (confocal, scanning interferometers, etc…).

View Article and Find Full Text PDF

Arrays of metallic thermocouples in the shape of spiral nanoantennas are proposed as infrared detectors, which use the thermoelectric properties of the metallic interfaces to generate electrical DC signals. The responsivity of these types of antennas is evaluated from both theoretical and numerical perspectives pointing out its potential as infrared sensors. Moreover, the same structures can be used to characterize the state of polarization of the optical near fields with a spatial resolution comparable to the wavelength.

View Article and Find Full Text PDF

Optical absorbance within a liquid is used as a photometric probe to measure the topography of optical surfaces relative to a reference. The liquid fills the gap between the reference surface and the measuring surface. By comparing two transmission images at different wavelengths we can profile the height distribution in a simple and reliable way.

View Article and Find Full Text PDF

An enhanced optical system design for NDIR gas detection is presented. Multiple paths lengths within the same cavity are used to auto reference the system. The system has good thermo-mechanical stability: it requires no special thermal stabilization, shows no sensitivity to thermal emitter drift and has no moving parts involved.

View Article and Find Full Text PDF