Cardiac arrhythmias cause depolarization waves to conduct unevenly on the myocardial surface, potentially delaying local components with respect to a previous beat when stimulated at faster frequencies. Despite the diagnostic value of localizing the distinct local electrocardiogram (EGM) components for identifying regions with decrement-evoked potentials (DEEPs), current software solutions do not perform automatic signal quantification. Electrophysiologists must manually measure distances on the EGM signals to assess the existence of DEEPs during pacing or extra-stimuli protocols.
View Article and Find Full Text PDFCardiol J
September 2021
Whether the sex factor influences the benefit of the implantable cardioverter-defibrillator (ICD) for the prevention of sudden death remains a subject of debate. Using a prospective registry, we sought to analyze the survival and time to first ICD therapy according to sex. Retrospective analysis of a prospective cohort of patients undergoing an ICD implant from 2008 to 2019.
View Article and Find Full Text PDFEuroIntervention
March 2019
Aims: We sought to compare the effects of intracoronary administration of a fibrinolytic drug (tenecteplase) to those of a glycoprotein IIb/IIIa inhibitor (abciximab) in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI).
Methods And Results: In this pilot trial, 76 patients (59 male) with anterior STEMI were randomised to intracoronary infusion of reduced-dose tenecteplase or abciximab during PPCI. Angiography was repeated at 48 hours to assess corrected TIMI frame count (cTFC) and TIMI myocardial perfusion grade (TMPG).
Background: Rates of cardiac-device infections have increased in recent years, but the current incidence and risk factors for infection in patients with implantable cardioverter-defibrillators (ICDs) are not well known.
Hypothesis: The increasing number of ICD infections is related to accumulated pocket manipulations over time.
Methods: This single-center, prospective study included patients that underwent ICD implantation from 2008 to 2015.
A virtual reconstruction of the geometry of the esophagus was produced using an electroanatomical mapping system and a specially designed catheter in 20 consecutive patients undergoing circumferential pulmonary vein isolation. The course of the esophagus, its motion and its proximity to the predicted lines of application of radiofrequency energy to the left atrium were evaluated. Thirteen (65%) were located centrally (i.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
July 2009
We report an unusual association of persistent atrial flutter and bundle branch re-entrant ventricular tachycardia in a young patient without structural heart disease. Atrial flutter masked the infra-Hisian conduction disease, was fundamentally dependent on a long PR interval, and could be a possible trigger of ventricular tachycardia.
View Article and Find Full Text PDF