Tech Innov Patient Support Radiat Oncol
June 2017
Demands for mechanical accuracy of medical linear accelerators are increased due to the stereotactic and modulated rotational treatments. Mechanical inaccuracies affect the size and shape of the mechanical and radiation isocenters. In practice, the mechanical isocenter is defined by the intersection of rotational axes.
View Article and Find Full Text PDFBackground: There has been a lack of methods to provide quantitative information of local tissue edema after burn injury. Noninvasive dielectric measurements provide this information. The measured value, the dielectric constant, is directly related to the amount of water in tissue.
View Article and Find Full Text PDFBackground And Purpose: To measure local changes of collagen metabolism in irradiated breast skin and systemic changes in serum during and after radiotherapy and correlate these changes with skin thickness, erythema and palpable subcutaneous induration.
Patients And Methods: Aminoterminal propeptides of type I and type III procollagens (PINP and PIIINP, respectively) were measured from skin suction blister fluid (SBF) in 21 breast cancer patients with breast conserving surgery and conventionally fractionated radiotherapy (RT) to a total dose of 50Gy. Suction blisters were induced in the operated and contralateral breast skin before RT, at 2.
Background/purpose: MoistureMeter is a novel capacitive device for measuring the hydration of stratum corneum (SC). The capacitor 'plates' are formed by the probe material and the well-conducting epidermal-dermal skin layers, while the dry layer of SC acts as an 'insulator' of the capacitor. Due to this measurement principle, the measurement depth is not constant, but equal to the thickness of the dry layer of SC.
View Article and Find Full Text PDFThe ability to objectively determine the degree of tissue edema and to monitor on-line fluid balance in critically ill patients would be a clinical benefit. In this prospective descriptive trial, we evaluated a new noninvasive method--dielectric constant of skin and subcutaneous fat (SSF)--in assessing fluid balance during cardiac surgery. The dielectric constant at the applied high radiofrequency is a direct measure of tissue water content.
View Article and Find Full Text PDFBackground/aims: Open chamber systems for measuring transepidermal water loss (TEWL) have limitations related to ambient and body-induced airflows near the probe, probe size, measurement sites and angles, and measurement range. The aim of the present investigation was to develop a closed chamber system for the TEWL measurement without significant blocking of normal evaporation through the skin. Additionally, in order to use the evaporimeter to measure evaporation rates through other biological and non-biological specimens and in the field applications, a small portable, battery-operated device was a design criteria.
View Article and Find Full Text PDF