Publications by authors named "Josue Junior Pierote"

Background: To evaluate the microtensile strength in the adhesive interface depending on the volume of the composite resin used to restore class I cavities.

Material And Methods: Forty-eight human third molars received a standardized class I cavity preparation and they were separated into six experimental groups: G1 - single-bottle adhesive system; G2 - bonding system with load; G3 - single-bottle adhesive associated with low-viscosity composite resin; G4 - loaded adhesive associated with low-viscosity composite; G5 - resin-modified glass ionomer associated with single-bottle adhesive; and G6 - resin-modified glass ionomer associated with loaded adhesive. All cavities were restored with a universal restorative composite.

View Article and Find Full Text PDF

To evaluate in vitro transenamel/transdentinal of penetration of HO after microabrasive. Computational models were performed to verify peroxide penetration and evaluate if geometric modifications could affect in vitro results. Enamel/dentin blocks from bovine incisors were prepared and randomly divided into groups (n = 15) according with abrasive (35% phosphoric acid and pumice or 6.

View Article and Find Full Text PDF

Background: To evaluate the influence of photoinitiators on the microtensile strength of adhesive systems and composite resins in bovine dentin.

Material And Methods: Forty dentin obtained from bovine teeth were randomly distributed in four groups (n = 10) according to the different adhesive systems and composite resins used: G1 - AAPS + VAPS (Ambar APS + Vittra APS); G2- AAPS + O (Ambar APS + Opallis); G3 - A + VAPS (Ambar + Vittra APS) and G4 - A + O (Ambar + Opallis). After restoration with the composite, the samples were sectioned to obtain toothpicks that were subjected to the microtensile and nanofiltration test (1.

View Article and Find Full Text PDF

Background: To evaluate the microtensile bond strength of indirect resin composite bonded to dentin using five different adhesives strategies.

Material And Methods: Forty specimens (Solidex) were produced and randomly into five groups with different adhesives strategies: (G1)- Single Bond Universal + etch + silane + RelyX Ultimate, (G2)- Single Bond Universal + silane + RelyX Ultimate, (G3)- Single Bond Universal + etch + RelyX Ultimate, (G4)- Single Bond Universal + RelyX Ultimate, and (G5)-Scotchbond Multi-purpose + RelyX ARC. After cementation the specimens were stored in 100% humidity for 24hours at 37°C.

View Article and Find Full Text PDF