Publications by authors named "Josephine O Kipp"

Article Synopsis
  • - The study aimed to evaluate the wrist stabilizing effects and mechanical properties of four different materials used for wrist splints, including plaster of Paris (PoP), Woodcast, X-lite, and a 3D-printed polypropylene material.
  • - Using cadaveric arm specimens, researchers tested how well each splint material resisted wrist flexion and extension under a controlled load, and they also conducted a bending test on samples of each material.
  • - Results showed that PoP provided superior wrist stability and stiffness compared to the other materials, suggesting it may be the best option for wrist immobilization despite new alternatives like 3D printing.
View Article and Find Full Text PDF

Purpose: Radial head arthroplasty (RHA) reestablishes elbow stability after complex radial head fracture, but complication rates are high, possibly due to inappropriate implant sizing. Knowledge of impact of radial head implant diameter on elbow kinematics is limited and warranted. This study evaluated elbow kinematics of different radial head implant diameters after RHA using dynamic radiostereometric analysis (dRSA).

View Article and Find Full Text PDF

Background: Cannulated screws are often used in the management of open lower extremity fractures. These fractures exhibit broad contamination profiles, necessitating empirical Gram-positive and Gram-negative antibiotic coverage. To ensure full antibiotic protection of the cannulated screw and the bone tissue, it is generally accepted that target tissue antibiotic concentrations, as a minimum, reach and remain above relevant epidemiological cut-off minimal inhibitory concentrations (T>MIC) for a sufficient amount of time.

View Article and Find Full Text PDF

Aims: Prompt and sufficient broad-spectrum empirical antibiotic treatment is key to preventing infection following open tibial fractures. Succeeding co-administration, we dynamically assessed the time for which vancomycin and meropenem concentrations were above relevant epidemiological cut-off (ECOFF) minimal inhibitory concentrations (T > MIC) in tibial compartments for the bacteria most frequently encountered in open fractures. Low and high MIC targets were applied: 1 and 4 µg/ml for vancomycin, and 0.

View Article and Find Full Text PDF

Background: Anastomotic leakage is a serious complication following gastrointestinal surgery and is associated with increased morbidity and mortality. The incidence of anastomotic leakage is determined by anatomy and is reported to be between 4%-33% for colon anastomosis and 1%-3% for small intestine anastomosis. The etiology of anastomotic leakage of the intestine has been divided into three main factors: healing disturbances, communication between intra- and extra-luminal compartments, and infection.

View Article and Find Full Text PDF

Two-stage revision with 'StageOne™ Select Hip Cement Spacer' is used as treatment of periprosthetic hip joint infection. The aim is to evaluate complications and restoration the joint with the StageOne Select Spacer. From 2013 to 2018 twenty-nine StageOne Select Spacers was inserted.

View Article and Find Full Text PDF