The demand for dental implants has increased, establishing them as the standard of care for replacing missing teeth. Several factors contribute to the success or failure of an implant post-placement. Modifications to implant surfaces can enhance the biological interactions between bone cells and the implant, promoting better outcomes.
View Article and Find Full Text PDFThis study aimed to comprehensively assess the influence of the nanotube diameter and the presence of a silicon carbide (SiC) coating on microbial proliferation on nanostructured titanium surfaces. An experiment used 72 anodized titanium sheets with varying nanotube diameters of 50 and 100 nm. These sheets were divided into four groups: non-coated 50 nm titanium nanotubes, SiC-coated 50 nm titanium nanotubes, non-coated 100 nm titanium nanotubes, and SiC-coated 100 nm titanium nanotubes, totaling 36 samples per group.
View Article and Find Full Text PDFOral cancer represents a significant global public health challenge, contributing substantially to the incidence and mortality of cancer. Despite established risk factors such as tobacco use and alcohol consumption, early detection remains crucial for effective treatment. This study introduces a novel approach using a transistor-based biosensor system for detecting the P90 (CIP2A) protein.
View Article and Find Full Text PDFJ Vac Sci Technol B Nanotechnol Microelectron
March 2024
The prevalence of breast cancer in women underscores the urgent need for innovative and efficient detection methods. This study addresses this imperative by harnessing salivary biomarkers, offering a noninvasive and accessible means of identifying breast cancer. In this study, commercially available disposable based strips similar to the commonly used glucose detection strips were utilized and functionalized to detect breast cancer with biomarkers of HER2 and CA15-3.
View Article and Find Full Text PDFPeri-implantitis is a major cause of dental implant failure. This disease is an inflammation of the tissues surrounding the implant, and, while the cause is multi-factorial, bacteria is the main culprit in initiating an inflammatory reaction. Dental implants with silicon carbonitride (SiCN) coatings have several potential advantages over traditional titanium implants, but their antibacterial efficiency has not yet been evaluated.
View Article and Find Full Text PDFThe application of surface coatings is a popular technique to improve the performance of materials used for medical and dental implants. Ternary silicon carbon nitride (SiCN), obtained by introducing nitrogen into SiC, has attracted significant interest due to its potential advantages. This study investigated the properties of SiCN films deposited via PECVD for dental implant coatings.
View Article and Find Full Text PDFJ Vac Sci Technol B Nanotechnol Microelectron
January 2023
Oral squamous cell carcinoma (OSCC) is one of the most common lip and oral cavity cancer types. It requires early detection via various medical technologies to improve the survival rate. While most detection techniques for OSCC require testing in a centralized lab to confirm cancer type, a point of care detection technique is preferred for on-site use and quick result readout.
View Article and Find Full Text PDFThe objective of this study was to evaluate the influence of the titanium nanotube diameter and the effect of silicon carbide (SiC) coating on the proliferation and mineralization of pre-osteoblasts on titanium nanostructured surfaces. Anodized titanium sheets with nanotube diameters of 50 and 100 nm were used. The following four groups were tested in the study: (1) non-coated 50 nm nanotubes; (2) SiC-coated 50 nm titanium nanotubes; (3) non-coated 100 nm nanotubes and (4) SiC-coated 100 nm nanotubes.
View Article and Find Full Text PDFJ Vac Sci Technol B Nanotechnol Microelectron
March 2022
The SARS-CoV-2 pandemic has had a significant impact worldwide. Currently, the most common detection methods for the virus are polymerase chain reaction (PCR) and lateral flow tests. PCR takes more than an hour to obtain the results and lateral flow tests have difficulty with detecting the virus at low concentrations.
View Article and Find Full Text PDFJ Vac Sci Technol B Nanotechnol Microelectron
March 2022
Leakage of human cerebrospinal fluid (CSF) caused by trauma or other reasons presents exceptional challenges in clinical analysis and can have severe medical repercussions. Conventional test methods, including enzyme-linked immunosorbent assay and immunofixation electrophoresis testing, typically are performed at a few clinical reference laboratories, which may potentially delay proper diagnosis and treatment. At the same time, medical imaging can serve as a secondary diagnosis tool.
View Article and Find Full Text PDFThe objective of this research was to quantify the effect of surface degradation and abrasion separately and in combination on the flexural strength of lithia disilicate ceramics. Lithia disilicate disks were fabricated using the lost wax technique and pressing in vacuum. The eight groups in this pilot experiment were (i) reference, hydrated in distilled water for 24 h prior to fracture; (ii) reference, non-hydrated group; (iii) 28-day pH cycling group; (iv) 125K chewing cycle group; (v) combined pH cycling + 125K chewing cycle; (vi) constant pH 2 solution for 28 days; (vii) constant pH 7 solution for 28 days; and (viii) constant pH 10 solution for 28 days.
View Article and Find Full Text PDFPeri-implantitis leads to implant failure and decreases long-term survival and success rates of implant-supported prostheses. The pathogenesis of this disease is complex but implant corrosion is believed to be one of the many factors which contributes to progression of this disease. A nanostructured titanium dioxide layer was introduced using anodization to improve the functionality of dental implants.
View Article and Find Full Text PDFThe objective of this study was to investigate the potential of titanium nanotubes to promote the proliferation of human osteoblasts and to reduce monomicrobial biofilm adhesion. A secondary objective was to determine the effect of silicon carbide (SiC) on these nanostructured surfaces. Anodized titanium sheets with 100-150 nm nanotubes were either coated or not coated with SiC.
View Article and Find Full Text PDFJ Vac Sci Technol B Nanotechnol Microelectron
May 2021
Detection of the SARS-CoV-2 spike protein and inactivated virus was achieved using disposable and biofunctionalized functional strips, which can be connected externally to a reusable printed circuit board for signal amplification with an embedded metal-oxide-semiconductor field-effect transistor (MOSFET). A series of chemical reactions was performed to immobilize both a monoclonal antibody and a polyclonal antibody onto the Au-plated electrode used as the sensing surface. An important step in the biofunctionalization, namely, the formation of Au-plated clusters on the sensor strips, was verified by scanning electron microscopy, as well as electrical measurements, to confirm successful binding of thiol groups on this Au surface.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
September 2021
This article describes the protocol for determining the cause of failure for retrieved failed implant supported fixed dental prostheses (FDPs) in a clinical study of three-unit bridges. The results of loading of flexure bars of different veneer compositions at different stress rates were presented for two veneer materials (leucite reinforced and fluorapatite glass-ceramic veneers) and a Y-TZP core zirconia ceramic used in the clinical study. From these results, the strengths of the fast loading conditions were used to determine the fracture toughness of these materials.
View Article and Find Full Text PDFStatement Of Problem: A silicon carbide (SiC) protective coating has been developed for dental ceramics, but whether the coated ceramics can match the classical VITA shades is unclear.
Purpose: The purpose of this observational in vitro study was to evaluate the color adaptability of SiC-coated dental ceramics by testing the hypotheses that SiC-coated disks can be fabricated to match standard tooth shades and have a perceptible color match rate of at least 50% for disks with a color difference (ΔE)<2.0.
The aim of this work is to investigate the effects produced by polymicrobial biofilm (, , , and ) on the corrosion behavior of titanium dental implants. Pure titanium disks were polished and coated with titanium nitride (TiN) and silicon carbide (SiC) along with their quarternized versions. Next, the disks were cultivated in culture medium (BHI) with , , , and and incubated anaerobically at 37 °C for 30 days.
View Article and Find Full Text PDFTitanium implants are commonly used in the field of dentistry for prosthetics such as crowns, bridges, and dentures. For successful therapy, an implant must bind to the surrounding bone in a process known as osseointegration. The objective for this ongoing study is to determine the potential of different implant surface coatings in providing the formation of hydroxyapatite (HA).
View Article and Find Full Text PDFTitanium (Ti) corrodes clinically in the presence of bacteria. We investigated this phenomenon as a function of Ti particles found in biopsied tissues around peri-implantitis sites and surface roughness of failed Ti implants. Tissue biopsies were surgically collected from peri-implantitis sites, processed, and embedded in resin.
View Article and Find Full Text PDFObjectives: To test the hypotheses that (a) the chairside/handheld dental scanner combined with a metrology software will measure clinical wear in vivo in agreement with measurements from X-ray computed microtomography and; (b) polished monolithic zirconia does not cause accelerated wear of opposing enamel.
Materials And Methods: Thirty single crowns were randomized to receive a monolithic zirconia or metal-ceramic crown. Two non-restored opposing teeth in the same quadrants were identified to serve as enamel controls.
The effect of pH changes on the chemical durability of dental glass-ceramic materials was evaluated using weight loss and ion release levels. The hypothesis that increased pH changes will exhibit greater corrosion was investigated. The ion concentration was analyzed using inductively coupled plasma atomic emission spectrometer (ICP).
View Article and Find Full Text PDFTitanium nitride (TiN) and silicon carbide (SiC) adhesion properties to biofilm and the proliferation of human osteoblasts were studied. Quaternized titanium nitride (QTiN) was produced by converting the surface nitrogen on TiN to a positive charge through a quaternization process to further improve the antibacterial efficiency. The SiC required a nitridation within the plasma chamber of the surface layer before quaternization could be carried out to produce quaternized SiC (QSiC).
View Article and Find Full Text PDFTo improve the chemical durability of SiC-based coatings on glass-ceramics, the effects of annealing and N plasma treatment were investigated. Fluorapatite glass-ceramic disks were coated with SiC via plasma-enhanced chemical vapor deposition (PECVD), treated with N plasma followed by an annealing step, characterized, and then immersed in a pH 10 buffer solution for 30 days to study coating delamination. Post-deposition annealing was found to densify the deposited SiC and lessen SiC delamination during the pH 10 immersion.
View Article and Find Full Text PDFA 200 nm plasma-enhanced chemical vapor-deposited SiC was used as a coating on dental ceramics to improve anti-bacterial properties for the applications of dental prosthesis. A thin SiO (20 nm) in the same system was deposited first, prior to SiC deposition, to improve the adhesion between SiC to dental ceramic. Silane and methane were the precursors for SiC deposition, and the SiO deposition employed silane and nitrous oxide as the precursors.
View Article and Find Full Text PDF