Aims: The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far.
Methods And Results: This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies.
Fabry disease (FD) is a rare X-linked lysosomal storage disorder that commonly manifests cardiovascular complications. We aimed to assess the prevalence of FD in a Chinese population with left ventricular hypertrophy (LVH) whilst implementing a gender-specific screening approach. Patients with LVH, defined as a maximum thickness of the left ventricular septal/posterior wall ≥ 13 mm, were considered eligible.
View Article and Find Full Text PDFAims: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated.
Methods: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied.
Background: Patients with heart failure and a non-left bundle branch block (non-LBBB) QRS pattern have a limited response to biventricular pacing (BVP).
Objective: A personalized cardiac resynchronization therapy (CRT) implantation approach guided by real-time electrocardiographic imaging (ECGi) was studied.
Methods: Twenty patients with left ventricular ejection fraction (LVEF) ≤ 35%, QRS duration ≥ 120 ms, and non-LBBB [13 (65%) with right bundle branch block and 7 (35%) with intraventricular conduction delay] were recruited.
Background: During slow pathway modification for atrioventricular nodal reentrant tachycardia, heart block may occur if ablation cannot be stopped in time in response to high risk electrogram features (HREF).
Objectives: To develop an automatic algorithm to monitor HREF and terminate ablation earlier than human reaction.
Methods: Digital electrogram data from 332 ablation runs from February 2020 to June 2022 were included.
Background: Cardiac resynchronization therapy (CRT) using biventricular pacing has limited efficacy in patients with heart failure (HF) and right bundle branch block (RBBB). Left bundle branch area pacing (LBBAP) is a novel physiologic pacing option.
Objective: The aim of the study was to assess the feasibility and outcomes of LBBAP in HF patients with RBBB and reduced left ventricular systolic function, and indication for CRT or ventricular pacing.
Background: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known.
Methods: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system.
EClinicalMedicine
August 2022
Background: This study aims to evaluate the association between thromboembolic events and hemorrhagic stroke following BNT162b2 and CoronaVac vaccination.
Methods: Patients with incident thromboembolic events or hemorrhagic stroke within 28 days of covid-19 vaccination or SARS-CoV-2 positive test during 23 February to 30 September 2021 were included. The incidence per 100,000 covid-19 vaccine doses administered and SARS-CoV-2 test positive cases were estimated.
Left ventricular hypertrophy (LVH) caused by cardiac variant Fabry disease (FD) is typically late-onset and may mimic LVH caused by abnormal loading conditions. We aimed to determine the prevalence of FD in a non-selective patient population of everyday practice presenting with LVH, including those with hypertension and valve disease. We measured plasma alpha-galactosidase A activity using dried blood spot tests in 499 (age = 66 ± 13 years; 336 men) Hong Kong Chinese patients with LVH defined as maximal LV septal/posterior wall thickness ≥13 mm on echocardiography.
View Article and Find Full Text PDFIntroduction: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio-ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study.
Methods: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis.
Fabry Disease (FD) is a systemic disorder that can result in cardiovascular, renal, and neurovascular disease leading to reduced life expectancy. FD should be considered in the differential of all patients with unexplained left ventricular hypertrophy (LVH). We therefore performed a prospective screening study in Edmonton and Hong Kong using Dried Blood Spot (DBS) testing on patients with undiagnosed LVH.
View Article and Find Full Text PDFBackground: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%.
View Article and Find Full Text PDFOur case illustrates the feasibility of high-risk PCI to salvage LMCA stenosis, possibly caused by coronary injury during direct coronary cardioplegia for a recent triple-valve operation.
View Article and Find Full Text PDFObjectives: This study reports on the performance of a leadless ventricular pacemaker with automated, enhanced accelerometer-based algorithms that provide atrioventricular (AV) synchronous pacing.
Background: Despite many advantages, leadless pacemakers are currently only capable of single-chamber ventricular pacing.
Methods: The prospective MARVEL 2 (Micra Atrial tRacking using a Ventricular accELerometer 2) study assessed the performance of an automated, enhanced accelerometer-based algorithm downloaded to the Micra leadless pacemaker for up to 5 h in patients with AV block.
Background Cardiac resynchronization therapy utilizing biventricular pacing is an effective therapy for patients with left ventricular (LV) systolic dysfunction, left bundle branch block, and heart failure. Benefits of biventricular pacing may be limited in patients with right bundle branch block (RBBB). Permanent His bundle pacing (HBP) has recently been reported as an option for cardiac resynchronization therapy.
View Article and Find Full Text PDFObjectives: This study assessed the defibrillation efficacy of the substernal-lateral electrode configuration.
Background: Subcutaneous implantable cardioverter-defibrillators (ICDs) are regarded as alternatives to transvenous ICDs in certain subjects. However, substantially higher shock energy of up to 80 J may be required.
J Cardiovasc Electrophysiol
September 2018
Background: Utilization of cardiac magnetic resonance imaging (cMRI) as an imaging modality in clinical practice is rapidly increasing. More evidence from randomized studies establishing clinical safety and performance of pacing systems in patients undergoing a cMRI scan is needed.
Objectives: The purpose of this prospective, multicenter, randomized study was to demonstrate safety and efficacy of the Accent MRI™ conditional pacing systems (St.
Cremation of implanted cardiac electronic devices can be associated with explosion from rapid gas formation causing potential hazard to the crematoria staffs and facilities. We present four patients who had undergone cremation with a leadless pacemaker (Micra , Medtronic Inc., Minneapolis, MN, USA) left inside their bodies.
View Article and Find Full Text PDFIntroduction: Cardiac contractility modulation (CCM) has been shown to be effective in improving symptoms and cardiac function in heart failure (HF). However, there is limited data on the role of CCM on long-term survival, which was explored in the present study.
Methodology: Forty-one consecutive HF patients with left ventricular ejection fraction (EF) <40% received CCM and were followed for approximately 6 years.
Introduction: Right atrial (RA) appendage pacing may prolong atrial conduction time (ACT). This study aimed to investigate if RA appendage pacing can induce intra- and interatrial dyssynchrony and if atrial dysfunction and dyssynchrony can predict atrial high rate episodes (AHREs) in the first year after pacing.
Methods And Results: Patients implanted with dual-chamber pacemakers for symptomatic bradycardia were enrolled.
Background: Elevated admission glucose level is a strong predictor of short-term adverse outcome in patients with acute coronary syndrome (ACS). However, the prognostic value of diabetic control (ie, hemoglobin A(1c) levels) in patients with ACS is still undefined.
Hypothesis: Hemoglobin A(1c) level may predict short-term outcome in patients with ACS.
Aims: Right ventricular apex (RVA) pacing may have deleterious effects on left ventricular (LV) systolic function, but its impact on LV diastolic function has not been explored.
Methods And Results: Ninety-seven patients with sinus node dysfunction and ejection fraction (EF) ≥ 50% with permanent RVA pacing were randomly programmed to V-sense and V-pace modes and examined by echocardiography. Tissue Doppler imaging was employed to assess myocardial systolic velocity (S') and early diastolic velocity (E') at the mitral annulus.