Adv Radiat Oncol
January 2023
Purpose: This article presents enhancements to a 4-dimensional (4D) lung digital tomosynthesis (DTS) model introduced in a 2018 paper. That model was proposed as an adjunct to 4D computed tomography (4DCT) to improve tumor localization through artifact reduction achieved by imaging the entire lung in all projections, reducing the projection collection time duration for each phase compared with 4DCT, and requiring only a single-breath cycle to capture all phases. This is applicable to SABR treatment planning.
View Article and Find Full Text PDFVascular damage and inflammation are limiting toxic effects of lung cancer radiotherapy, which lead to pneumonitis and pulmonary fibrosis. We have demonstrated that soy isoflavones (SIF) mitigate these toxic effects at late time points after radiation. However, the process by which SIF impacts the onset of radiation-induced inflammation remains to be elucidated.
View Article and Find Full Text PDFPurpose: This is an investigation of a lung motion digital tomosynthesis (DTS) model using combined stationary detector and stationary cold cathode x-ray sources at projection acquisition rates that exceed the present norms. The intent is to reduce anatomical uncertainties from artifacts inherent in thoracic 4-dimensional computed tomography (CT).
Methods And Materials: Parameters necessary to perform rapid lung 4-dimensional DTS were studied using a conventional radiographic system with linear motion of the x-ray source and a simple hypothetical hardware performance model.
Background: We previously demonstrated that tumor irradiation potentiates cancer vaccines using genetic modification of tumor cells in murine tumor models. To investigate whether tumor irradiation augments the immune response to MUC1 tumor antigen, we have tested the efficacy of tumor irradiation combined with an MVA-MUC1-IL2 cancer vaccine (Transgene TG4010) for murine renal adenocarcinoma (Renca) cells transfected with MUC1.
Methods: Established subcutaneous Renca-MUC1 tumors were treated with 8 Gy radiation on day 11 and peritumoral injections of MVA-MUC1-IL2 vector on day 12 and 17, or using a reverse sequence of vaccine followed by radiation.
Purpose: In this investigation, we sought to characterize X-ray beam qualities and quantitate percent depth dose (PDD) curves for fluoroscopic X-ray beams incorporating added copper (Cu) filtration, such as those commonly used in fluoroscopically guided interventions (FGI). The intended application of this research is for dosimetry in soft tissue from FGI procedures using these data.
Methods: All measurements in this study were acquired on a Siemens (Erlangen, Germany) Artis zeego fluoroscope.
Characteristic X rays of energies less than approximately 20 keV are of interest in radiobiology and radiation oncology. There is evidence that these low-energy photons produce higher relative biological effectiveness (RBE) and lower oxygen enhancement ratio (OER) relative to higher energies. Lower energy X rays also offer the advantage of healthy tissue sparing beyond the target treatment depth.
View Article and Find Full Text PDFThe first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (CC) determined at a single beam quality and applied to the measured Ka,r over a broad spectrum of beam qualities. Eleven state-of-the-art interventional fluoroscopes were evaluated, consisting of eight Siemens Artis zee and Artis Q systems and three Philips Allura FD systems.
View Article and Find Full Text PDFPurpose: PTW's Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results.
View Article and Find Full Text PDFA comprehensive end-to-end test for head and neck IMRT treatments was developed using a custom phantom designed to utilize multiple dosimetry devices. Initial end-to-end test and custom H&N phantom were designed to yield maximum information in anatomical regions significant to H&N plans with respect to: (i) geometric accuracy, (ii) dosimetric accuracy, and (iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies.
View Article and Find Full Text PDFModern fluoroscopes used for image-based guidance in interventional procedures are complex X-ray machines, with advanced image acquisition and processing systems capable of automatically controlling numerous parameters based on defined protocol settings. This study evaluated and compared approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and variable copper filter thickness over a wide range of simulated tissue thicknesses.
View Article and Find Full Text PDFPurpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA.
Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.
Clin Neurol Neurosurg
October 2013
Background: Metastases to the brainstem portend a poor prognosis and present a challenge in clinical management. Surgical resection is rarely a viable option.
Methods: Post-treatment MRI scans of patients with brainstem metastases treated with radiosurgery were used to determine local control and disease progression.
Our institution delivers TBI using a modified Theratron 780 60Co unit. Due to limitations of our treatment planning system in calculating dose for this treatment, we have developed a fast Monte Carlo code to calculate dose distributions within the patient. The algorithm is written in C and uses voxel density information from CT images to calculate dose in heterogeneous media.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2012
Calvarial reconstruction following resection of tumors involving the skull is often followed by stereotactic radiosurgery. Prior studies have addressed the effects of various cranioplasty materials on dose distributions in linac-based radiosurgery. We aim to determine the effects of titanium mesh implants on Gamma Knife dose.
View Article and Find Full Text PDFIncreased consumption of cruciferous vegetables is associated with decreased risk in prostate cancer (PCa). The active compound in cruciferous vegetables appears to be the self dimerized product [3,3'-diindolylmethane (DIM)] of indole-3-carbinol (I3C). Nutritional grade B-DIM (absorption-enhanced) has proven safe in a Phase I trial in PCa.
View Article and Find Full Text PDFBackground: We have demonstrated that soy isoflavones radiosensitize cancer cells. Prostate cancer patients receiving radiotherapy (RT) and soy tablets had reduced radiation toxicity to surrounding organs. We have now investigated the combination of soy with RT in lung cancer (NSCLC), for which RT is limited by radiation-induced pneumonitis.
View Article and Find Full Text PDFDigital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angles to the reconstruction tomogram. The digital nature of the data allows for input images to be combined into the desired plane with the flexibility of generating tomograms of many separate planes from a single set of input data.
View Article and Find Full Text PDF