Purpose: The intravitreal injection volume is known to vary with plunger alignment and the speed of injection. We investigated the role that syringe stopper deformation plays in allowing excess volumes to be injected into the eye and the potential for the vitreous humor to become incarcerated when excess force is released within the eye.
Design: Experimental study.
Ophthalmic Surg Lasers Imaging Retina
October 2021
Background And Objective: To facilitate timely surgery and efficient use of operating room time, our practice uses a team-based approach so patients may undergo primary rhegmatogenous retinal detachment (RRD) surgery with a different surgeon instead of the diagnosing surgeon.
Patients And Methods: This was a retrospective cohort study of 331 eyes that underwent RRD surgery. Patients were divided into two groups: RRD surgery performed by the diagnosing surgon, and RRD surgery performed by a different surgeon.
Purpose: The aim of this study was to test the discomfort experienced during intravitreal injections with eyelid retraction between an eyelid speculum, cotton-tipped applicator (CTA), and unimanual eyelid retraction techniques.
Methods: In total, 99 patients receiving intravitreal bevacizumab were enrolled into this prospective study. Participants were randomized to one of the three methods, given subconjunctival 2% lidocaine and then injected in the superior temporal quadrant.
Pentosan Polysulfate Sodium (PPS) is commonly used in the treatment of interstitial cystitis/bladder pain syndrome. Recently there have been reported cases of retinal toxicity associated with long-term PPS use. We present a case of a 42-year-old female taking PPS for the last 10 years who was found to have signs of retinal toxicity, but was completely asymptomatic.
View Article and Find Full Text PDFRetin Cases Brief Rep
May 2021
Background/purpose: Report a case of markedly asymmetric retinal tessellations and propose mosaicism as a mechanism.
Methods And Results: A 59-year-old pseudophakic woman presented with uncorrected 20/20 vision and was found to have markedly different retinal tessellation appearances in both eyes. The axial lengths were 25.
Case Rep Ophthalmol
January 2018
Purpose: To report a case of intravenous (i.v.) heroin use-associated endogenous endophthalmitis caused by fungal species, and its response to intravitreal and oral voriconazole treatments.
View Article and Find Full Text PDF