With the current development of the 5G infrastructure, there presents a unique opportunity for the deployment of battery-less mmWave reflect-array-based sensors. These fully-passive devices benefit from having a larger detectability than alternative battery-less solutions to create self-monitoring megastructures. The presented 'smart' skin sensor uses a Van-Atta array design enabling ubiquitous local strain monitoring for the structural health monitoring of composite materials featuring wide interrogation angles.
View Article and Find Full Text PDFBackground: Prognostic factors for total shoulder arthroplasty (TSA) clinical outcomes are incompletely understood. This study investigates the associations of preoperative patient, disease-specific, and surgical factors with 1-year postoperative PENN Shoulder Score (PSS) in patients undergoing primary TSA.
Methods: Cleveland Clinic patients undergoing primary anatomic TSA (aTSA) or reverse TSA (rTSA) for glenohumeral osteoarthritis (GHOA) or rotator cuff tear arthropathy (CTA) between February 2015 and August 2019, and having complete preoperative and 1-year postoperative patient-reported outcome measures (PROMs), were included.
Background: This study's purpose was to investigate the extent to which differences among operating surgeons may influence 1-year patient-reported outcome measures (PROMs) in patients undergoing rotator cuff repair (RCR) surgery, after controlling for general and disease-specific patient factors. We hypothesized that surgeon would be additionally associated with 1-year PROMs, specifically the baseline to 1-year improvement in Penn Shoulder Score (PSS).
Methods: We used mixed multivariable statistical modeling to assess the influence of surgeon (and alternatively surgical case volume) on 1-year PSS improvement in patients undergoing RCR at a single health system in 2018, controlling for eight patient- and six disease-specific preoperative factors as possible confounders.
J Shoulder Elbow Surg
January 2024
Curr Rev Musculoskelet Med
March 2023
Purpose Of Review: As reverse total shoulder arthroplasty indications have expanded and the incidence of its use has increased, developments in implant design have been a critical component of its success. The purpose of this review is to highlight the recent literature regarding the effect of implant design on reverse total shoulder arthroplasty biomechanics.
Recent Findings: Implant design for reverse total shoulder arthroplasty has evolved considerably from the modern design developed by Paul Grammont.
Background: Magnetic resonance imaging (MRI)-based rotator cuff assessment is often qualitative and subjective; few studies have tried to validate such preoperative assessments. This study investigates relationships of preoperative MRI assessments made by conventional approaches to intraoperative findings of tear type, location, and size or MRI-assessed muscle occupation ratio.
Methods: Intraoperatively, surgeons assessed tear type, location, anterior-posterior (AP) width, and medial-lateral length in 102 rotator cuff repair patients.
Background: Severe glenoid bone loss (SGBL) poses significant technical challenges. Adequate fixation of glenoid implants may require the use of alternative screw placement. Although bone volumes for the spine and lateral pillars have previously been defined, insufficient evidence exists regarding the distribution of screw placement for fixation in such regions for cases with SGBL.
View Article and Find Full Text PDFBackground: The purpose of this study was to demonstrate the validity and efficiency of the Outcomes Management and Evaluation (OME) system, a prospectively designed electronic data collection tool, for collecting comprehensive and standardized surgical data in shoulder arthroplasty.
Methods: Surgical data from the first 100 cases of shoulder arthroplasty that were collected into the OME database were analyzed. Surgeons completed a traditional narrative operative note and also an OME case report using an encrypted smartphone.
Background: Most orthopaedic journals currently require reporting outcomes of surgical interventions for at least 2 postoperative years, but there have been no rigorous studies on this matter. Various patient-reported outcome (PRO) measures (PROMs) have been used to assess the status of the shoulder after rotator cuff repair (RCR).
Hypothesis: We hypothesized that the mean shoulder-specific PROMs at 1 year improve substantially over baseline but that there is no clinically meaningful difference between the mean 1- and 2-year PROMs after RCR.
Glenoid component loosening remains a common complication following anatomic total shoulder arthroplasty (TSA); however, plain radiographs are unable to accurately detect early implant migration. The purpose of this study was to validate the accuracy of a method of postoperative, three-dimensional (3D) computed tomography (CT) imaging with metal artifact reduction (MAR) to detect glenoid component migration following anatomic TSA. Tantalum bead markers were inserted into polyethylene glenoid components for implant detection on 3D CT.
View Article and Find Full Text PDFBackground: Posterior glenoid bone loss is commonly associated with primary glenohumeral osteoarthritis. Surgical management of bone loss in anatomic total shoulder arthroplasty (aTSA) remains controversial. We studied the use of a stepped augmented glenoid component for management of Walch B2 and B3 glenoids and compared the radiographic and clinical outcomes at short-term follow-up with those achieved with a non-augmented component of the same design in Walch A1 glenoids.
View Article and Find Full Text PDFBackground: Magnetic resonance imaging (MRI) is standard of care for rotator cuff evaluation, with clinical interpretation usually limited to qualitative judgments. The reliability of MRI-based measurements and scoring systems has been evaluated only preoperatively or ≥6 months following rotator cuff repair, when repairs are in the later stages of healing. This study describes the MRI assessments and inter-rater agreement of various rotator cuff tendon and muscle parameters evaluated preoperatively and 4 times during the first postoperative year.
View Article and Find Full Text PDFBackground: Acromial (ASF) and scapular spine (SSF) stress fractures are well-recognized complications of reverse shoulder arthroplasty (RSA), but much of the current data are derived from single-center or single-implant studies with limited generalizability. This study from the American Shoulder and Elbow Surgeons (ASES) Complications of Reverse Shoulder Arthroplasty Multicenter Research Group determined the incidence of ASF/SSF after RSA and identified preoperative patient characteristics associated with their occurrence.
Method: Fifteen institutions including 21 ASES members across the United States participated in this study.
Cases: Two patients presented to different surgeons complaining of persistent shoulder pain after reverse total shoulder arthroplasty. Workups for fracture, instability, and periprosthetic infection were negative. Advanced imaging, nerve conduction studies, and diagnostic injections localized symptoms to the suprascapular nerve.
View Article and Find Full Text PDFBackground: To address the need for more objective and quantitative measures of tendon healing in research studies, we intend to use computed tomography (CT) with implanted radiopaque markers on the repaired tendon to measure tendon retraction following rotator cuff repair. In our small prior study, retraction at 1-year follow-up averaged 16.1± 5.
View Article and Find Full Text PDFObjective: To determine whether a simulated low-dose metal artifact reduction (MAR) CT technique is comparable with a clinical dose MAR technique for shoulder arthroplasty evaluation.
Materials And Methods: Two shoulder arthroplasties in cadavers and 25 shoulder arthroplasties in patients were scanned using a clinical dose (140 kVp, 300 qrmAs); cadavers were also scanned at half dose (140 kVp, 150 qrmAs). Images were reconstructed using a MAR CT algorithm at full dose and a noise-insertion algorithm simulating 50% dose reduction.
Hypothesis And Background: Shoulder pain and dysfunction are common indications for shoulder arthroplasty, yet the factors that are associated with these symptoms are not fully understood. This study aimed to investigate the associations of patient and disease-specific factors with preoperative patient-reported outcome measures (PROMs) in patients undergoing primary shoulder arthroplasty. We hypothesized that worse mental health status assessed by the Veterans RAND 12-Item Health Survey (VR-12) mental component score (MCS), glenoid bone loss, and increasing rotator cuff tear severity would be associated with lower values for the preoperative total Penn Shoulder Score (PSS) and its pain, function, and satisfaction subscores.
View Article and Find Full Text PDFBackground: Glenoid component loosening is a common cause of failure after anatomic total shoulder arthroplasty. Prior studies of all-polyethylene glenoid implants with hybrid fixation did not show early glenoid radiolucency to be clinically significant. The purpose of this study was to determine the clinical significance of progression of radiolucency around the central peg of the glenoid component.
View Article and Find Full Text PDFBackground: The purpose of this study was to quantify correction of glenoid deformity and humeral head alignment in anatomic total shoulder arthroplasty as a function of preoperative pathology (modified Walch classification) and glenoid implant type in a clinical cohort using 3-dimensional computed tomography (CT) analysis.
Methods: Patients undergoing anatomic total shoulder arthroplasty with a standard glenoid (SG) (n = 110) or posteriorly stepped augmented glenoid (AG) (n = 62) component were evaluated with a preoperative CT scan and a postoperative CT scan within 3 months of surgery. Glenoid version, inclination, and medial-lateral (ML) joint line position, as well as humeral head alignment, were assessed on both CT scans, with preoperative-to-postoperative changes analyzed relative to pathology and premorbid anatomy based on the modified Walch classification and glenoid implant type.
Background: Variations in glenoid morphology affect surgical treatment and outcome of advanced glenohumeral osteoarthritis (OA). The purpose of this study was to assess the inter- and intraobserver reliability of the modified Walch classification using 3-dimensional (3D) computed tomography (CT) imaging in a multicenter research group.
Methods: Deidentified preoperative CTs of patients with primary glenohumeral OA undergoing anatomic or reverse total shoulder arthroplasty (TSA) were reviewed with 3D imaging software by 23 experienced shoulder surgeons across 19 institutions.