Publications by authors named "Josef Tauss"

Sanguineous splenic complications in elective treatment procedures remain a potentially life-threatening complication in patients of all age groups. In this case, the patient, as per her past medical history, underwent a laparoscopic appendectomy when she was admitted to the clinic. One of the diagnostic procedures to find the reason for the epigastric pain, a gastroscopy, can retrospectively be held responsible for decapsulation of the spleen.

View Article and Find Full Text PDF

Hepatic encephalopathy (HE) is a common problem after insertion of a trans-jugular intrahepatic portosystemic shunt (TIPS), which may be difficult to manage. We present a case of severe post-TIPS HE unresponsive to high doses of L-ornithine-L-aspartate (LOLA) despite reduction of venous ammonia levels in a dose-dependent fashion. Ultimately, high-grade HE was successfully treated by a reduction stent and the patient subsequently underwent successful liver transplantation.

View Article and Find Full Text PDF

Gorham-Stout syndrome is a rare disease characterized by vascular proliferation in the bones, effecting osteolysis. When it is complicated by chylothorax, the prognosis is poor. The present case illustrates successful management of chylothorax by a combination of surgery (thoracic duct ligation and excision of lymphangiomatous tissue combined with pleurodesis) and treatment with alpha-2b interferon.

View Article and Find Full Text PDF

Purpose: To describe a technique for repositioning a fully deployed iliac stent from the infrarenal aorta into the common iliac artery (CIA).

Case Report: A 58-year-old man was undergoing treatment for a significant right CIA stenosis when a 7x24-mm Palmaz Genesis medium stent was mistakenly deployed in the infrarenal aorta. With the stent still over the guidewire, an 8x60-mm balloon catheter was placed coaxially in the stent.

View Article and Find Full Text PDF

Purpose: To report the initial experience with a new catheter system (The Outback catheter) designed to allow fluoroscopically controlled re-entry of the true arterial lumen after subintimal guidewire passage during recanalization procedures of arterial occlusions.

Methods: The catheter was used in 10 patients with intermittent claudication caused by chronic segmental occlusions of the superficial femoral or popliteal arteries. In all patients, conventional guidewire recanalization had failed.

View Article and Find Full Text PDF

Purpose: To evaluate the midterm clinical results and patency of transjugular portosystemic shunts (TIPS) created with a commercially available expanded polytetrafluoroethylene (ePTFE)-covered stent-graft based on angiographic and ultrasonographic (US) criteria in a series of 71 patients.

Materials And Methods: Seventy-one patients (61 men, 10 women; mean age, 58.6 years, range, 25-78 years) were included in this series, which was performed in two centers.

View Article and Find Full Text PDF

Purpose: The potential of semitransparent volume-rendering (STVR) computed tomographic (CT) angiography was evaluated for the assessment of hemodynamically significant stenoses in aortoiliac arteriosclerotic disease.

Materials And Methods: In a prospective study, 76 patients (57 men, 19 women; mean age, 70 years) underwent single-detector (n = 26) or multidetector (n = 50) CT angiography of the aortoiliac region. Intraarterial digital subtraction angiography (DSA) was performed in each patient.

View Article and Find Full Text PDF

The aim of this study was to evaluate the healing response to a new commercially available ePTFE-covered stent graft used to create transjugular intrahepatic portosystemic shunts (TIPS) in an animal model with and without intraluminal irradiation. The study was designed for ten domestic normotensive pigs. The TIPS was created using a ePTFE-covered stent graft (Viatorr, Gore, Flagstaff, Ariz.

View Article and Find Full Text PDF

Purpose: To assess the efficacy and safety of the Rotarex rotational thrombectomy catheter in treating occlusions of the femoropopliteal arteries.

Methods: The Rotarex catheter (Straub Medical, Switzerland) is a rotational thrombectomy device which is supposed to be able to remove fresh and partially organized clot material from an acutely or subacutely occluded vessel. Nineteen limbs of 18 patients (10 women, 8 men; mean age 72.

View Article and Find Full Text PDF