Grit basting is the most common process applied to titanium dental implants to give them a roughness that favors bone colonization. There are numerous studies on the influence of roughness on osseointegration, but the influence of the compressive residual stress associated with this treatment on biological behavior has not been determined. For this purpose, four types of surfaces have been studied using 60 titanium discs: smooth, smooth with residual stress, rough without stress, and rough with residual stress.
View Article and Find Full Text PDFStatement Of Problem: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests.
Objective: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests.
Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-implantitis following the criteria of Renvert et al.
View Article and Find Full Text PDFThe procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol.
View Article and Find Full Text PDFThe stability and integrity of the abutment-implant connection, by means of a screw, is fallible from the moment the prosthetic elements are joined and is dependent on the applied preload, wear of the components and function. One of the main causes of screw loosening is the loss of preload. The loosening of the screw-abutment can cause complications such as screw fracture, marginal gap, peri-implantitis, bacterial microleakage, loosening of the crown and discomfort of the patient.
View Article and Find Full Text PDFThe purpose of this research is to study the biomechanical response of dental implants in bone-level type locations, 0.5 mm above and below the bone level. In addition, the influence of the thickness of the cortical bone on osseointegration is determined due to the mechanical loads transfer from the dental implant to the cortical and trabecular bone.
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2021
Implant dentistry has evolved over time, resulting in better treatment outcomes for both patients and clinicians. The aim of this trial was to test whether the immediate loading of implants with a platform-switching design influences the marginal bone level, compared to four-week loading, after one year of follow-up. Moreover, a comparison of clinical data regarding implant survival, implant stability, and patient-reported outcome measures (PROMs) was conducted.
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2021
According to classic Hirschfeld studies, the first teeth to be lost are the first and second maxillary molars. After the teeth are extracted and the alveolar process is developed, the maxillary sinus is reabsorbed and pneumatized with a decrease in bone availability in the posterior sector of the maxilla. This process often creates the need to perform regeneration techniques for the placement of implants in this area due to the low availability of bone.
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2021
Introduction: Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques.
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2021
Purpose: The aim of this retrospective study was to compare the influence of removing or not removing a prosthesis after regenerative surgery on peri-implant defects.
Methods: Two different groups were compared (Group 1: removing the prosthesis; Group 2: maintaining the prosthesis), analyzing radiographic bone filling (n = 32 implants) after regenerative treatment in periapical radiographs. The peri-implant defects were measured before and after regenerative treatment using Bio-Oss (Geistlich Pharma, Wohhusen, Switzerland) and a reabsorbable collagen membrane (Jason, Botis, Berlin, Germany), the healing period was two years after peri-implant regenerative surgery.
Int J Environ Res Public Health
December 2020
: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between the 1 mm high abutment group and 2 mm abutment group. Evaluate changes in implant stability recorded with analysis of the resonance frequency (RFA) Osstell system, at 6 and 12 months after implant placement, between the control group (HEA) and test (DEF).
View Article and Find Full Text PDFInt J Environ Res Public Health
December 2020
As immediate loading protocols are becoming more frequent, the primary stability of implants has become an essential criterion for the osseointegration of dental implants. Based on this, the objective of this study was to understand the influence of different undersized surgical preparation sites on the insertion torque (IT) and implant stability quotient (ISQ). Four different site-preparation protocols were performed on fresh humid type III bovine bone: one control, the standard protocol recommended by the manufacturer (P1), and three variations of undersized techniques (P2, P3 and P4).
View Article and Find Full Text PDFInt J Environ Res Public Health
November 2020
Resonance frequency analysis (RFA) requires abutment disconnection to monitor implant stability. To overcome this limitation, an experimental transepithelial abutment was designed to allow a SmartPeg to be screwed onto it, in order to determine the prototype abutments repeatability and reproducibility using Osstell ISQ and to assess whether implant length and diameter have an influence on the reliability of these measurements. RFA was conducted with a SmartPeg screwed directly into the implant and onto experimental abutments of different heights of 2, 3.
View Article and Find Full Text PDFInt J Environ Res Public Health
September 2020
Unlabelled: The aim of this study was to evaluate the changes in periodontal parameters solely using free gingival grafts during orthodontic treatment without any oral hygiene re-enforcement.
Methods: A total of 19 patients underwent periodontal examination before orthodontic treatment. Patients received oral hygiene instruction and professional hygiene therapy.
Numerous randomised controlled multicentric studies have investigated various responses to different treatment modalities with dental implants. These studies do not always show the results of daily practice as they are performed under controlled and strict clinical conditions. This multicentric, non-interventionist trial aimed to document the behaviour of implants when used in daily dental practice, without inclusion or exclusion criteria.
View Article and Find Full Text PDFImplant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4).
View Article and Find Full Text PDFThe aim of this study was to compare the quality of different computer-assisted-design and computer assisted manufacturing systems (CAD-CAM) generated by only one scanner, focusing on vertical fit discrepancies and the mechanical properties. A master model was obtained from a real clinical situation: the replacement of an absent (pontic) tooth, with the construction of a fixed partial denture on natural abutments with three elements. Nine scans were performed by each tested and 36 copies were designed using a dental CAD-CAM software (Exocad).
View Article and Find Full Text PDFIn order to apply the "one-abutment-one-time" concept, we evaluated the possibility of measuring resonance frequency analysis (RFA) on the abutment. This trial aimed to compare the Implant Stability Quotient (ISQ) values obtained by the Penguin when screwing the transducer onto the implant or onto abutments with different heights and angulations. Eighty implants (VEGA, Klockner Implant System, SOADCO, Les Escaldes, Andorra) were inserted into fresh bovine ribs.
View Article and Find Full Text PDFImplants inserted in the posterior maxilla frequently need additional surgery for successful bone augmentation. One of the most common procedures for this is transalveolar sinus floor elevation. There are different protocols for this procedure, and there is controversy over the simultaneous application of grafting material upon elevating.
View Article and Find Full Text PDFStatement Of Problem: Implant abutment selection is complex because of the numerous factors involved. Computer-aided design (CAD) technology allows for the virtual selection and placement of abutments after all parameters have been precisely measured. The outcome of this new protocol should be validated.
View Article and Find Full Text PDFUnlabelled: Adequate implant stability is an essential requirement. The introduction of the Penguin resonance frequency analysis raises some questions regarding its reliability, reproducibility, and repeatability as well as how it compares to the older Osstell device.
Purpose: To assess the newer Penguin implant stability coefficient (ISQ) device (vs the Osstell device).
Purpose: The objective of this study was to assess the influence of a novel surface of dental implants (ContacTi) on the osseointegration process in a minipig model. The surface was compared with other existing surfaces on the market (SLA and SLActive) by employing bone implant contact analysis (BIC) and implant stability.
Method: Twelve minipigs were used with prior authorisation from an ethics committee.
The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption.
View Article and Find Full Text PDF