The elbow is one of the most commonly dislocated joints. Although simple dislocations of the elbow usually resolve with conservative management, certain patients can experience residual chronic instability. Posterolateral rotational instability accounts for approximately 80% of elbow chronic instability cases.
View Article and Find Full Text PDFIntroduction: In the process of bone regeneration, a prominent role is played by macrophages involved in both the initial inflammation and the regeneration/vascularization phases, due to their M2 anti-inflammatory phenotype. Together with osteoclasts, they participate in the degradation of the bone matrix if the inflammatory process does not end. In this complex scenario, recently, much attention has been paid to extracellular communication mediated by nanometer-sized vesicles, with high information content, called exosomes (EVs).
View Article and Find Full Text PDFClin Oral Investig
May 2024
Clin Oral Investig
January 2024
J Clin Sleep Med
March 2024
Study Objectives: Maxillomandibular advancement surgery (MMA) is a therapeutic option for obstructive sleep apnea (OSA). The main objective of this study was to determine the impact of MMA on the physical and airflow characteristics of the upper airway based on data obtained by computational fluid dynamics (CFD) and to correlate these data with polysomnography parameters. Other objectives included the identification of presurgical variables that could help avoid surgeries likely to have a low success rate.
View Article and Find Full Text PDFBioengineering (Basel)
May 2023
This study aimed to assess the bone regeneration of critical-size defects in rabbit calvaria filled with freshly crushed extracted teeth, comparing them with BTCP biomaterial and empty sites. Materials and methods: Twenty-one female New Zealand rabbits were used in this study. Two critical-size defects 6 mm in size were created in the skull bone, each with a 3 mm separation between them.
View Article and Find Full Text PDFThis prospective clinical study involved 20 patients in whom implants were immediately placed in extraction sockets. Residual bone defects were grafted, and the buccal bone plate was overcontoured with a xenogeneic bone substitute and covered by a collagen membrane. One year after implant placement, CBCT images were acquired to evaluate buccal bone, and implant stability was analyzed through resonance frequency analysis.
View Article and Find Full Text PDF: The aim of this study is to evaluate the efficacy of an autologous dentin graft, via extracted teeth that are processed into bacteria-free particulate dentin in a Smart dentin grinder and then grafted immediately into alveolus post extraction or into bone deficiencies. Ten healthy, partially edentulous patients with some teeth in the mandible were recruited in the study. After their own teeth were grinded, particulate teeth were placed in empty sockets and bone defects after teeth extractions.
View Article and Find Full Text PDFClin Oral Investig
February 2022
Aim: To observe clinically and radiographically (CBCT), the extent of bone resorption in extraction socket without the use of bone graft substitutes and delayed implant placement.
Material And Methods: 50 compliant patients were selected for study. All the patients who were advised extraction were followed up for entire duration of the treatment, at 5th week CBCT showed horizontal and vertical bone loss.
To evaluate whether sinus augmentation, using a minimally invasive implant device, via a non-submerged surgical approach, might negatively influence the outcome. A retrospective cohort study was conducted by evaluating patients' files, classifying them into two groups. Fifty patients (22 men 28 women) were included in the study, 25 in each group.
View Article and Find Full Text PDFIn many clinical situations, rehabilitation with implants in the posterior maxillary region is complicated by limited bone availability. In this context, the use of 4 mm long implants (known as extra-short implants) may be used thanks to the concept of osseointegration enhancement. It has been demonstrated that short implants offer an alternative to the regeneration procedures involved in placing longer implants in areas where bone height is compromised.
View Article and Find Full Text PDFCalcium phosphate materials are widely used as bone substitutes due to their bioactive and biodegradable properties. Also, the presence of silicon in their composition seems to improve the bioactivity of the implant and promote bone tissue repair. The aim of this study was to develop a novel ceramic scaffold by partial solid-state sintering method with a composition lying in the field of the Nurse's A-phase-silicocarnotite, in the tricalcium phosphate-dicalcium silicate (TCP-CS) binary system.
View Article and Find Full Text PDFBackground: The aim of this study was to retrospectively analyze two different sealing techniques for sinus membrane perforations produced during sinus floor augmentation by a lateral approach.
Methods: A total of 172 lateral-approach sinus floor augmentation surgeries were performed on 130 patients. Sixty-one membrane perforations (35%) were reported.
Closure of the surgical incision has been the primary function of sutures since their introduction. However, whatever the type, they are known to carry bacteria, which can be a source of infection. Five types of surgical sutures, Gut, Silk, Vicryl, PTFE, and Polyamide, were selected and tested on their ability to carry aerobic and anaerobic bacteria and were rated on the basis of forming colony-forming units (CFUs).
View Article and Find Full Text PDFThe occlusal forces and their influence on the initiation of peri-implant bone loss or their relationship with peri-implantitis have created discussion during the past 30 years given the discrepancies observed in clinical, animal, and finite element analysis studies. Beyond these contradictions, in the case of an osseointegrated implant, the occlusal forces can influence the implant-bone interface and the cells responsible for the bone remodeling in different ways that may result in the maintenance or loss of the osseointegration. This comprehensive review focuses on the information available about the forces transmitted through the implant-crown system to the implant-bone interface and the mechano-transduction phenomena responsible for the bone cells' behavior and their interactions.
View Article and Find Full Text PDFBackground: The goal of this study was to analyze the stress distribution on two types of extra-short dental implants with 5 mm of length: An internal hexagon (IH) and morse taper connection (MT).
Methods: The three-dimensional model was composed of trabecular and cortical bone, a crown, an extra-short dental implant and their components. An axial load of 150 N was applied and another inclined 30° with the same magnitude.
In relation to the article of the Journal of Clinical and Experimental Dentistry "Calvo-Guirado JL, Aguilar-Salvatierra A, Guardia J, Delgado-Ruiz R, Ramírez-Fernández MP, Pérez-Sánchez C, Gómez-Moreno G. Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.
View Article and Find Full Text PDFThis animal study evaluated the osseointegration level of a new nanotextured titanium surface produced by anodization. Ti-cp micro-implants (1.5 mm diameter by 2.
View Article and Find Full Text PDFBackground: The implant design and the surgical technique are important parameters that can be modified to improve the implant primary stability. The aim of this study was to evaluate the role of the apical part of an implant on the implant stability of implants placed in Type II dense bone by novice and experienced clinicians.
Methods: Implants with a progressive thread design (3.
Threads of dental implants with healing chamber configurations have become a target to improve osseointegration. This biomechanical and histometric study aimed to evaluate the influence of implant healing chamber configurations on the torque removal value (RTv), percentage of bone-to-implant contact (BIC%), bone fraction occupancy inside the thread area (BAFO%), and bone and osteocyte density (Ost) in the rabbit tibia after two months of healing. Titanium implants with three different thread configurations were evaluated: Group 1 (G1), with a conventional "v" thread-shaped implant design; Group 2 (G2), with square threads; and Group 3 (G3), the experimental group with longer threads (healing chamber).
View Article and Find Full Text PDF