Curr Probl Cardiol
January 2025
Introduction: Left bundle branch area pacing (LBBAP) seems to be an alternative to coronary sinus pacing in patients with non-ischaemic dilated cardiomyopathy (NI-DCM) with left bundle branch block (LBBB) and in pacing-induced cardiomyopathy (PICM). The aim of the study was to compare the response of LBBAP in severe forms of both entities.
Material And Methods: Prospective study of patients with severe forms of PICM and NI-DCM in NYHA II-IV who underwent LBBAP.
The balloon-assisted tracking technique can be useful in short venous occlusions that conventional venoplasty fails. This technique could be feasible and with an expected low complication rate.
View Article and Find Full Text PDFProsthesis-patient mismatch (PPM) occurs when the effective orifice area of the prosthesis is too small in relation to the patient's body surface area. There are few data available on the frequency and prognostic impact of PPM after transcatheter aortic valve implantation (TAVI). Our aim was to determine the prevalence of PPM and to investigate its association with medium-term clinical course of patients undergoing TAVI.
View Article and Find Full Text PDFAm J Cardiol
November 2016
New-onset conduction disturbances are common after transcatheter aortic valve implantation (TAVI). The most common complication is left bundle branch block (LBBB). The clinical impact of new-onset LBBB after TAVI remains controversial.
View Article and Find Full Text PDFIntroduction And Objectives: Conduction disturbances often occur after CoreValve transcatheter aortic valve implantation. The aim was to analyze which cardiac conduction changes occur in patients with aortic stenosis treated with this type of prosthesis.
Methods: A total of 181 patients with severe aortic stenosis treated with this prosthesis and studied by electrocardiography between April 2008 and December 2013 were selected.
Echocardiography
April 2011
Aims: To compare the measurements of the aortic annulus obtained with various imaging techniques in patients with severe aortic stenosis scheduled for transcatheter aortic valve implantation, and to determine the grade of agreement between the predicted size of the prosthesis for each technique, and the size of the finally implanted valve.
Methods And Results: The aortic annulus was measured in 40 patients treated by transcatheter aortic valve implantation (CoreValve aortic valve) with transthoracic (TTE) and transesophageal echocardiography (TEE), 64-slice tomography, and angiography. A large valve was implanted when annulus was >23 mm and a small one if it was ≤23 mm.