We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load.
View Article and Find Full Text PDFInt J Sports Physiol Perform
January 2022
Purpose: To examine the reproducibility (intradevice and interdevice agreement) of the Rotor 2INpower device under a wide range of cycling conditions.
Methods: Twelve highly trained male cyclists and triathletes completed 5 cycling tests, including graded exercise tests at different cadences (70-100 rpm), workloads (100-650 W), pedaling positions (seated and standing), and vibration conditions (20-40 Hz) and an 8-second maximal sprint (>1000 W). An intradevice analysis included a comparison between the power output registered by 3 units of Rotor 2INpower, whereas the power output provided by each one of these units and the gold-standard SRM crankset were compared for the interdevice analysis.
This study aimed to examine the validity and reliability of the recently developed Assioma Favero pedals under laboratory cycling conditions. In total, 12 well-trained male cyclists and triathletes (VO = 65.7 ± 8.
View Article and Find Full Text PDFLillo-Beviá, JR, Courel-Ibáñez, J, Cerezuela-Espejo, V, Morán-Navarro, R, Martínez-Cava, A, and Pallarés, JG. Is the functional threshold power a valid metric to estimate the maximal lactate steady state in cyclists? J Strength Cond Res 36(1): 167-173, 2022-The aims of this study were to determine (a) the repeatability of a 20-minute time-trial (TT20), (b) the location of the TT20 in relation to the main physiological events of the aerobic-anaerobic transition, and (c) the predictive power of a list of correction factors and linear/multiple regression analysis applied to the TT20 result to estimate the individual maximal lactate steady state (MLSS). Under laboratory conditions, 11 trained male cyclists and triathletes (V̇o2max 59.
View Article and Find Full Text PDFTo validate the new PowerTap P1 pedals power meter (PP1), thirty-three cyclists performed 12 randomized and counterbalanced graded exercise tests (100-500 W), at 70, 85 and 100 rev·min cadences, in seated and standing positions. A scientific SRM system and a pair of PP1 pedals continuously recorded cadence and power output data. Significantly lower power output values were detected for the PP1 compared to the SRM for all workloads, cadences, and pedalling conditions (2-10 W, p < 0.
View Article and Find Full Text PDF