Publications by authors named "Jose M Manero"

The Boston Keratoprosthesis (BKPro) serves as a medical solution for restoring vision in complex cases of corneal blindness. Comprising a front plate made of polymethylmethacrylate (PMMA) and a back plate of titanium (Ti), this device utilizes the beneficial biomaterial properties of Ti. While BKPro demonstrates promising retention rates, infection emerges as a significant concern that impacts its long-term efficacy.

View Article and Find Full Text PDF
Article Synopsis
  • The rat, particularly its tibia, is a key animal model in studying implant dentistry and orthopedics due to its easy surgical access and ability to mimic human diseases.
  • This study involved 80 Sprague Dawley rats with osteoporosis and Type 2 Diabetes, assessing the biological response to implant placement at 4 and 12 weeks, with consistent surgical methods applied.
  • Results showed successful osseointegration of implants in both disease models, indicating stable integration over time and providing a benchmark for future biomaterials research.
View Article and Find Full Text PDF
Article Synopsis
  • Integrin α5β1 plays a key role in how cells attach and move, making it important for development and healing, with its binding proteins being useful in regenerative medicine.* -
  • Researchers developed custom proteins called NeoNectins that specifically target and stabilize the active form of α5β1, leading to improved cell attachment and spread in lab tests.* -
  • When used on titanium surfaces and in 3D hydrogels, NeoNectins showed better results compared to traditional options in boosting tissue integration and bone growth in animal studies, highlighting their potential in biomedicine.*
View Article and Find Full Text PDF

Bacterial infection remains a significant problem associated with orthopaedic surgeries leading to surgical site infection (SSI). This unmet medical need can become an even greater complication when surgery is due to malignant bone tumor. In the present study, we evaluated in vitro titanium (Ti) implants subjected to gallium (Ga) and silver (Ag)-doped thermochemical treatment as strategy to prevent SSI and improve osteointegration in bone defects caused by diseases such as osteoporosis, bone tumor, or bone metastasis.

View Article and Find Full Text PDF

Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants.

View Article and Find Full Text PDF

Soft tissue defects, such as incisional hernia or pelvic organ prolapse, are prevalent pathologies characterized by a tissue microenvironment rich in fragile and dysfunctional fibroblasts. Precision medicine could improve their surgical repair, currently based on polymeric materials. Nonetheless, biomaterial-triggered interventions need first a better understanding of the cell-material interfaces that truly consider the patients' biology.

View Article and Find Full Text PDF

Excessive bone resorption is one of the main causes of bone homeostasis alterations, resulting in an imbalance in the natural remodeling cycle. This imbalance can cause diseases such as osteoporosis, or it can be exacerbated in bone cancer processes. In such cases, there is an increased risk of fractures requiring a prosthesis.

View Article and Find Full Text PDF

The Boston keratoprosthesis (BKPro) is a medical device used to restore vision in complicated cases of corneal blindness. This device is composed by a front plate of polymethylmethacrylate (PMMA) and a backplate usually made of titanium (Ti). Ti is an excellent biomaterial with numerous applications, although there are not many studies that address its interaction with ocular cells.

View Article and Find Full Text PDF

Previously, functional coatings on 3D-printed titanium implants were developed to improve their biointegration by separately incorporating Ga and Ag on the biomaterial surface. Now, a thermochemical treatment modification is proposed to study the effect of their simultaneous incorporation. Different concentrations of AgNO and Ga(NO) are evaluated, and the obtained surfaces are completely characterized.

View Article and Find Full Text PDF

The formation of a biological seal around the neck of titanium (Ti) implants is critical for ensuring integration at the gingival site and for preventing bacterial colonization that may lead to periimplantitis. This process is guided by activated fibroblasts, named myofibroblasts, which secrete extracellular matrix (ECM) proteins and ECM-degrading enzymes resolving the wound. However, in some cases, Ti is not able to attract and activate fibroblasts to a sufficient extent, which may compromise the success of the implant.

View Article and Find Full Text PDF

The 3D printing of titanium (Ti) offers countless possibilities for the development of personalized implants with suitable mechanical properties for different medical applications. However, the poor bioactivity of Ti is still a challenge that needs to be addressed to promote scaffold osseointegration. The aim of the present study was to functionalize Ti scaffolds with genetically modified elastin-like recombinamers (ELRs), synthetic polymeric proteins containing the elastin epitopes responsible for their mechanical properties and for promoting mesenchymal stem cell (MSC) recruitment, proliferation, and differentiation to ultimately increase scaffold osseointegration.

View Article and Find Full Text PDF

The rapid integration in the bone tissue and the prevention of bacterial infection are key for the success of the implant. In this regard, a silver (Ag)-doped thermochemical treatment that generate an Ag-doped calcium titanate layer on titanium (Ti) implants was previously developed by our group to improve the bone-bonding ability and provide antibacterial activity. In the present study, the biological and antibacterial potential of this coating has been further studied.

View Article and Find Full Text PDF

Present commercial titanium alloy implants have an elastic modulus higher than 100 GPa, whereas that of the cortical bone is much smaller (17−28 GPa). This elastic modulus mismatch produces a stress shielding effect and the resorption of the bone surrounding the implant. In the present work, a <100> fiber texture is developed in β type Ti-42Nb (wt%) alloy ingots generated by laser-directed energy deposition (LDED) in order to achieve anisotropic mechanical properties.

View Article and Find Full Text PDF

The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties.

View Article and Find Full Text PDF

The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO) on the surface of the material in order to improve its behavior against corrosion and prevent the release of ions into the physiological environment. The most common chemical agent for the passivation process is hydrochloric acid (HCl), and in this work we intend to determine the capacity of citric acid as a passivating and bactericidal agent. Discs of commercially pure titanium (c.

View Article and Find Full Text PDF

The surface modification by the formation of apatitic compounds, such as hydroxyapatite, improves biological fixation implants at an early stage after implantation. The structure, which is identical to mineral content of human bone, has the potential to be osteoinductive and/or osteoconductive materials. These calcium phosphates provoke the action of the cell signals that interact with the surface after implantation in order to quickly regenerate bone in contact with dental implants with mineral coating.

View Article and Find Full Text PDF

One possibility to prevent prosthetic infections is to produce biomaterials resistant to bacterial colonization by anchoring membrane active antimicrobial peptides (AMPs) onto the implant surface. In this perspective, a deeper understanding of the mode of action of the immobilized peptides should improve the development of AMP-inspired infection-resistant biomaterials. The aim of the present study was to characterize the bactericidal mechanism against Staphylococcus epidermidis of the AMP BMAP27(1-18), immobilized on titanium disks and on a model resin support, by applying viability counts, Field Emission Scanning Electron Microscopy (FE-SEM), and a fluorescence microplate assay with a membrane potential-sensitive dye.

View Article and Find Full Text PDF

Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised.

View Article and Find Full Text PDF

Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their reliability and to evaluate the causes of the fracture. These NDIs were compared with other similar implants, made with alloyed titanium with 15% Zr and with 12% strained titanium. Original implants were tested under static and fatigue conditions, simulating the tri-axial loads in the mouth by means of a Bionix hydraulic test machine.

View Article and Find Full Text PDF

Bacterial infection of orthopaedic implants, often caused by Staphylococcus species, may ultimately lead to implant failure. The development of infection-resistant, osteoblast-compatible biomaterials could represent an effective strategy to prevent bacterial colonization of implants, reducing the need for antibiotics. In this study, the widely used biomaterial titanium was functionalized with BMAP27(1-18), an α-helical cathelicidin antimicrobial peptide that retains potent staphylocidal activity when immobilized on agarose beads.

View Article and Find Full Text PDF

Biomaterial-associated infections (BAI) are the major cause of failure of indwelling medical devices. The risk of BAI can end dramatically in the surgical removal of the affected device. Therefore, a major effort must be undertaken to guarantee the permanence of the implant.

View Article and Find Full Text PDF

The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption.

View Article and Find Full Text PDF

Synergizing integrin and cell-membrane heparan sulfate proteoglycan signaling on biomaterials through peptidic sequences is known to have beneficial effects in the attachment and behavior of osteoblasts; however, controlling the exact amount and ratio of peptides tethered on a surface is challenging. Here, we present a dual molecular-based biointerface combining integrin (RGD) and heparin (KRSR)-binding peptides in a chemically controlled fashion. To this end, a tailor-made synthetic platform (PLATF) was designed and synthesized by solid-phase methodologies.

View Article and Find Full Text PDF

Installing bioactivity on metallic biomaterials by mimicking the extracellular matrix (ECM) is crucial for stimulating specific cellular responses to ultimately promote tissue regeneration. Fibronectin is an ECM protein commonly used for biomaterial functionalization. The use of fibronectin recombinant fragments is an attractive alternate to the use of full-length fibronectin because of the relatively low cost and facility of purification.

View Article and Find Full Text PDF

Peri-implantitis is an infectious disease that affects the supporting soft and hard tissues around dental implants and its prevalence is increasing considerably. The development of antibacterial strategies, such as titanium antibacterial-coated surfaces, may be a promising strategy to prevent the onset and progression of peri-implantitis. The aim of this study was to quantify the biofilm adhesion and bacterial cell viability over titanium disc with or without antibacterial surface treatment.

View Article and Find Full Text PDF