In this work, we study the characteristics of femtosecond-filament-laser-matter interactions and laser-induced periodic surface structures (LIPSS) at a beam-propagation distance up to 55 m. The quantification of the periodicity of filament-induced self-organized surface structures was accomplished by SEM and AFM measurements combined with the use of discrete two-dimensional fast Fourier transform (2D-FFT) analysis, at different filament propagation distances. The results show that the size of the nano-scale surface features increased with ongoing laser filament processing and, further, periodic ripples started to form in the ablation-spot center after irradiation with five spatially overlapping pulses.
View Article and Find Full Text PDFThe contribution and impact of combined laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) and laser-induced breakdown spectroscopy (LIBS) were evaluated for the discrimination analysis of different coal samples. This tandem approach allows simultaneous determination of major and minor elements (C, H, Si, Ca, Al, Mg, etc.) and trace elements (V, Ba, Pb, U, etc.
View Article and Find Full Text PDFLaser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES) were used simultaneously for the elemental analysis of asphaltene samples using minimum sample pretreatment in combination with low laser energy to reduce the amount of removed particles and avoid carbon deposits in the ablation cell. Quantitative analyses of S, Ni, and V were accomplished with LA-ICP-OES using external calibration with the C line as internal standard. The aromatic/paraffinic nature of the asphaltenes was also obtained throughout the H/C ratio using LIBS and partial least square regression model.
View Article and Find Full Text PDFWe evaluated the performance of laser ablation analysis techniques such as laser-induced breakdown spectroscopy (LIBS), laser ablation inductively coupled optical emission spectrometry (LA-ICP-OES), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), in comparison with that of ICP-OES using aqueous solutions for the quantification of sulfur (S) in edible salts from different geographical origins. We found that the laser ablation based sampling techniques were not influenced by loss of S, which was observed in ICP-OES with aqueous solutions for a certain salt upon their dissolution in aqueous solutions, originating from the formation of volatile species and precipitates upon their dilution in water. Although detection of S using direct laser sampling with LA-ICP-MS has well-known isobaric and polyatomic interferences, LIBS and LA-ICP-OES showed good accuracy in the detection of S for all salts.
View Article and Find Full Text PDFDirect solid sampling by laser ablation into an inductively coupled plasma synchronous vertical dual view optical emission spectroscope (LA-SVDV-ICP-OES) was used for the elemental analysis of nutrient elements Ca, B, Mn, Mg, K, and Zn and essential (non-metallic) elements P and S in plant materials. The samples were mixed with paraffin as a binder, an approach that provides better cohesion of the particles in the pellets in addition to supplying carbon to serve as an internal standard (atomic line C I 193.027 nm) as a way to compensate for matrix effects, and/or variations in the ablation process.
View Article and Find Full Text PDFLiquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma is being developed as a secondary vaporization-excitation source for the optical emission analysis of laser ablation (LA)-generated particle populations. The practicalities of this coupling are evaluated by determining the influence of source parameters on the emission response and the plasma's robustness upon LA introduction of easily ionized elements (EIEs). The influence of discharge current (45-70 mA), LA carrier gas flow rate (0.
View Article and Find Full Text PDFA coupling of thin layer chromatography with laser ablation ICP SF MS was developed for the fractionation of Ni, V, Fe and S in crude oil and its fractions (saturate, aromatic, resin and asphaltene). The detection limits were 18 ng g(-1) and 23 ng g(-1) for nickel and vanadium, respectively, and a sample could be characterized in terms of the metal distribution as a function of species polarity within 10 min. The method was used to characterize the metal distribution in crude oils of different origins and their different fractions.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
May 2012
Segmentation of the lung is particularly difficult because of the large variation in image quality. A modified Hough transform in combination with a mask creation algorithm can robustly determine synchronous respiratory patterns. The synchronicity restriction is relaxed by applying a greedy active contour algorithm.
View Article and Find Full Text PDFA dual-beam photothermal reflection based system capable to measure thermal diffusivities of optically dense liquids has been designed and implemented. The large optical absorption coefficient of these liquids inhibits the possibility to use conventional transmission instruments for direct thermal diffusivity measurements. To overcome this problem, a front heating front detection photothermal reflection system has been proposed.
View Article and Find Full Text PDFJ Trace Elem Med Biol
July 2009
This study focuses on the determination of iodine content in healthy thyroid samples on male population from Caracas, Venezuela. Contribution to establish a baseline of iodine content in thyroid glands and hence to compare the iodine thyroid concentration of the Venezuelan population with other countries is also our objective. Male post-mortem individual samples were analyzed using a spectrophotometric flow injection method, based on the Sandell-Kolthoff reaction.
View Article and Find Full Text PDFA dual sample introduction system was explored for volatile hydride generation in inductively coupled plasma-optical emission spectrometry (ICP-OES) performed in the radially viewed mode. The system consists of two pneumatic nebulizers connected to the conventional spray chamber of the instrument via a simple adaptor. This configuration permits hydride generation but still allows other elements to be determined by pneumatic nebulization.
View Article and Find Full Text PDFA direct hydride generation nebulizer (DHGN) was explored for introduction of the sample in inductively coupled plasma-optical emission spectrometry (ICP-OES) using radially viewed mode. This simple hydride generation system was constructed in our laboratory and requires similar plasma operating conditions to conventional nebulizer-spray-chamber arrangements. This work was focused on the optimization of the operating conditions for hydride generation and evaluation of the main analytical figures of merit for the determination of As, Sb and Se.
View Article and Find Full Text PDFExperimental studies and computer simulations were conducted to identify plasma operating conditions and to explore and contrast the excitation conditions of Ar, Ar-O2, and Ar-He inductively coupled plasmas (ICPs) for the introduction of microliter volumes of sample solutions with a direct injection high efficiency nebulizer (DIHEN). The best MgII 280.270 nm/MgI 285.
View Article and Find Full Text PDF