Purpose: Describe complications, functional success, and retention of the Lucia Keratoprosthesis (KPro).
Design: Retrospective interventional case series METHODS: The demographic data, baseline characteristics, complications, functional success, and retention were analyzed for Lucia KPro at the Instituto de Oftalmologia Conde de Valenciana in Mexico City from 2021 to 2023. Multivariate regression analysis and Kaplan-Meier plots were performed to identify associations with functional failure.
The study of corneal biomechanics has become relevant in recent years due to its possible applications in the diagnosis, management, and treatment of various diseases such as glaucoma, keratorefractive surgery and different corneal diseases. The clinical biomechanical investigation has become of great importance in the setting of refractive surgery to identify patients at higher risk of developing iatrogenic ectasia. This review focuses on two of the technologies available for clinical use, the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Buffalo, NY, USA) and the Corvis ST (Oculus Optikgergäte GmbH, Wetzlar, Germany).
View Article and Find Full Text PDFPurpose: The aim of this study was to report a case of ocular Mpox that responded favorably to treatment with topical interferon and oral doxycycline.
Methods: This is a case report of a previously healthy 24-year-old woman who developed a pustular rash, headache, fever, arthralgia, sore throat, and asthenia 3 weeks before attending to our clinic. Her main complaint at the moment of the visit was pain, photophobia, foreign body sensation, blurred vision, red eye, and discharge on the left eye.
Purpose Of Review: Review building of programs to eliminate infections.
Recent Findings: Morbidity and mortality from toxoplasmosis led to programs in USA, Panama, and Colombia to facilitate understanding, treatment, prevention, and regional resources, incorporating student work.
Summary: Studies foundational for building recent, regional approaches/programs are reviewed.
Purpose: To evaluate repeatability, reproducibility, and accordance between ocular surface measurements within three different imaging devices.
Methods: We performed an observational study on 66 healthy eyes. Tear meniscus height, non-invasive tear break-up time (NITBUT) and meibography were measured using three corneal imaging devices: Keratograph 5M (Oculus, Wetzlar, Germany), Antares (Lumenis, Sidney, Australia), and LacryDiag (Quantel Medical, Cournon d'Auvergne, France).
Objectives: To determine the frequency of retinochoroidal lesions by ocular toxoplasmosis and their relationships with risk factors, in residents of two districts with high exposure to in Armenia-Quindío, Colombia.
Methods: Cross-sectional analyses of fundoscopy screening, serological tests, and questionnaires were performed to determine risk factors associated with ocular toxoplasmosis retinochoroidal lesions. Differences in proportions were analyzed using the chi-squared test.
Purpose: To describe ocular surface characteristics and tests' results in a healthy pediatric population.
Methods: We performed a cross-sectional study with 60 healthy children, obtaining consent, OSDI and screen use survey and conducting ocular surface tests. Statistical univariate analysis for categorical and quantitative variables was made.