Publications by authors named "Joris Jaspers"

Cardiovascular diseases (CVDs) are a global burden that requires attention. For the detection and diagnosis of CVDs, the 12-lead ECG is a key tool. With technological advancements, ECG devices are becoming smaller and available for home use.

View Article and Find Full Text PDF

Background: Portable, smartphone-sized electrocardiography (ECG) has the potential to reduce time to treatment for patients suffering acute cardiac ischemia, thereby lowering the morbidity and mortality. In the UMC Utrecht, a portable, smartphone-sized, multi-lead precordial ECG recording device (miniECG 1.0, UMC Utrecht) was developed.

View Article and Find Full Text PDF

Aims: Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these devices are single lead and only intended for rhythm disorders. We developed the miniECG, a smartphone-sized portable device with four dry electrodes capable of recording a high-quality multi-lead ECG by placing the device on the chest. The aim of our study was to investigate the ability of the miniECG to detect occlusive myocardial infarction (OMI) in patients with chest pain.

View Article and Find Full Text PDF

Background: Electrocardiograms (ECGs) are used by physicians to record, monitor, and diagnose the electrical activity of the heart. Recent technological advances have allowed ECG devices to move out of the clinic and into the home environment. There is a great variety of mobile ECG devices with the capabilities to be used in home environments.

View Article and Find Full Text PDF

Background: With the growing shortage of nurses, labor-saving technology has become more important. In health care practice, however, the fit with innovations is not easy. The aim of this study is to analyze the development of a mobile input device for electronic medical records (MEMR), a potentially labor-saving application supported by nurses, that failed to meet the needs of nurses after development.

View Article and Find Full Text PDF

Background: The use of 3D laparoscopic systems is expanding. The European Association of Endoscopic Surgery (EAES) initiated a consensus development conference with the aim of creating evidence-based statements and recommendations for the surgical community.

Methods: Systematic reviews of the PubMed and Embase libraries were performed to identify evidence on potential benefits of 3D on clinical practice and patient outcomes.

View Article and Find Full Text PDF

Operating rooms (ORs) more and more evolve into high-tech environments with increasing pressure on finances, logistics, and a not be neglected impact on patient safety. Safe and cost-effective implementation of technological equipment in ORs is notoriously difficult to manage, specifically as generic implementation activities omit as hospitals have implemented local policies for implementations of technological equipment. The purpose of this study is to identify success factors for effective implementations of new technologies and technological equipment in ORs, based on a systematic literature review.

View Article and Find Full Text PDF

Background: Existing laparoscopic instrument holders do not seem to sufficiently fulfil the needs of surgeons performing minimally invasive surgery (MIS) in several respects. Therefore, we developed and tested a novel laparoscopic instrument positioner in close cooperation between surgeons and engineers.

Material And Methods: Design requirements were established by attending laparoscopic interventions, interviews and involving surgeons during the design cycle by evaluation of early mock-ups and prototypes.

View Article and Find Full Text PDF

Introduction: Since the da Vinci robotic system was introduced, it has been reported to have ergonomic advantages over conventional laparoscopy (COV). High investments associated with this system challenged us to design a more economical, mechanical alternative for improvement of laparoscopic ergonomics: the Minimally Invasive Manipulator (MIM).

Material And Methods: An earlier reported MIM prototype was investigated.

View Article and Find Full Text PDF

Obtaining access to blood vessels can be difficult, especially in children. Visualization of subsurface blood vessels might be a solution. Ultrasound and visible light have been used to this purpose, but have some drawbacks.

View Article and Find Full Text PDF

During minimally invasive procedures an assistant is controlling the laparoscope. Ideally, the surgeon should be able to manipulate all instruments including the camera him/herself, to avoid communication problems and disturbing camera movements. Camera holders return camera-control to the surgeon and stabilize the laparoscopic image.

View Article and Find Full Text PDF

A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit into the Data Spectrum anthropomorphic torso phantom. Flexible silicone membranes form the inner and outer walls of the simulated left ventricle.

View Article and Find Full Text PDF