Background: Electromagnetic navigation bronchoscopy (ENB) has been widely adopted as a guidance technique for biopsy of peripheral lung nodules. However, ENB is limited by the lack of real-time confirmation of the biopsy devices. Intraprocedural cone-beam computed tomography (CBCT) imaging can be utilized to assess or confirm the location of biopsy devices.
View Article and Find Full Text PDFObjective: To provide insight into how and in what clinical fields overdiagnosis is studied and give directions for further applied and methodological research.
Design: Scoping review.
Data Sources: Medline up to August 2017.
Importance: Fibrinogen concentrate might partly restore coagulation defects and reduce intraoperative bleeding.
Objective: To determine whether fibrinogen concentrate infusion dosed to achieve a plasma fibrinogen level of 2.5 g/L in high-risk cardiac surgery patients with intraoperative bleeding reduces intraoperative blood loss.
Background: A physician is frequently unable to distinguish bacterial from viral infections. ImmunoXpert is a novel assay combining three proteins: tumour necrosis factor-related apoptosis-inducing ligand (TRAIL), interferon gamma induced protein-10 (IP-10), and C-reactive protein (CRP). We aimed to externally validate the diagnostic accuracy of this assay in differentiating between bacterial and viral infections and to compare this test with commonly used biomarkers.
View Article and Find Full Text PDFBackground: Ten events per variable (EPV) is a widely advocated minimal criterion for sample size considerations in logistic regression analysis. Of three previous simulation studies that examined this minimal EPV criterion only one supports the use of a minimum of 10 EPV. In this paper, we examine the reasons for substantial differences between these extensive simulation studies.
View Article and Find Full Text PDFBMC Pregnancy Childbirth
September 2016
Background: Stillbirth is a major contributor to perinatal mortality and it is particularly common in low- and middle-income countries, where annually about three million stillbirths occur in the third trimester. This study aims to develop a prediction model for early detection of pregnancies at high risk of stillbirth.
Methods: This retrospective cohort study examined 6,573 pregnant women who delivered at Federal Medical Centre Bida, a tertiary level of healthcare in Nigeria from January 2010 to December 2013.
Background: C-reactive protein (CRP) is increasingly being included in the diagnostic work-up for community-acquired pneumonia in primary care. Its added diagnostic value beyond signs and symptoms, however, remains unclear. We conducted a meta-analysis of individual patient data to quantify the added value of CRP measurement.
View Article and Find Full Text PDFBackground: Pneumonia remains difficult to diagnose in primary care. Prediction models based on signs and symptoms (S&S) serve to minimize the diagnostic uncertainty. External validation of these models is essential before implementation into routine practice.
View Article and Find Full Text PDFResults obtained using a reference standard may be missing for some participants in diagnostic accuracy studies. This paper looks at methods for dealing with such missing data when designing or conducting a prospective diagnostic accuracy study
View Article and Find Full Text PDFBackground: To describe approaches used in systematic reviews of diagnostic test accuracy studies for assessing variability in estimates of accuracy between studies and to provide guidance in this area.
Methods: Meta-analyses of diagnostic test accuracy studies published between May and September 2012 were systematically identified. Information on how the variability in results was investigated was extracted.
Objectives: The objective of this study was to evaluate the performance of goodness-of-fit testing to detect relevant violations of the assumptions underlying the criticized "standard" two-class latent class model. Often used to obtain sensitivity and specificity estimates for diagnostic tests in the absence of a gold reference standard, this model relies on assuming that diagnostic test errors are independent. When this assumption is violated, accuracy estimates may be biased: goodness-of-fit testing is often used to evaluate the assumption and prevent bias.
View Article and Find Full Text PDFBackground: Small-study effects and time trends have been identified in meta-analyses of randomized trials. We evaluated whether these effects are also present in meta-analyses of diagnostic test accuracy studies.
Methods: A systematic search identified test accuracy meta-analyses published between May and September 2012.
Background: The results obtained from various point-of-care (POC) test devices for estimating C-reactive protein (CRP) levels in a laboratory setting differ when compared to a laboratory reference test. We aimed to determine whether such differences meaningfully affect the accuracy and added diagnostic value in predicting radiographic pneumonia in adults presenting with acute cough in primary care.
Methods: A nested case control study of adult patients presenting with acute cough in 12 different European countries (the Genomics to combat Resistance against Antibiotics in Community-acquired LRTI in Europe [GRACE] Network).
Ned Tijdschr Geneeskd
July 2015
The accuracy of diagnostic tests is of utmost importance as biased test results may lead to wrong decisions in clinical practice. In diagnostic accuracy research the results of a diagnostic test, model or strategy are compared to those of the reference standard, i.e.
View Article and Find Full Text PDFCarl Moons and colleagues provide a checklist and background explanation for critically appraising and extracting data from systematic reviews of prognostic and diagnostic prediction modelling studies. Please see later in the article for the Editors' Summary.
View Article and Find Full Text PDFAims: Hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) has only been evaluated for its diagnostic accuracy as a single test in patients suspected of significant coronary artery disease (CAD). Added value of hybrid SPECT/CCTA beyond usual clinical work-up, or use of each of these tests separately, remains unclear. We evaluated the added value of hybrid myocardial perfusion SPECT (SPECT) and CCTA, beyond pre-test likelihood and exercise stress ECG (X-ECG), in the diagnosis of CAD.
View Article and Find Full Text PDFObjectives: To examine how authors explore and report on sources of heterogeneity in systematic reviews of diagnostic accuracy studies.
Study Design And Setting: A cohort of systematic reviews of diagnostic tests was systematically identified. Data were extracted on whether an exploration of the sources of heterogeneity was undertaken, how this was done, the number and type of potential sources explored, and how results and conclusions were reported.
Background: Drawing conclusions from systematic reviews of test accuracy studies without considering the methodological quality (risk of bias) of included studies may lead to unwarranted optimism about the value of the test(s) under study. We sought to identify to what extent the results of quality assessment of included studies are incorporated in the conclusions of diagnostic accuracy reviews.
Methods: We searched MEDLINE and EMBASE for test accuracy reviews published between May and September 2012.
Latent class models (LCMs) combine the results of multiple diagnostic tests through a statistical model to obtain estimates of disease prevalence and diagnostic test accuracy in situations where there is no single, accurate reference standard. We performed a systematic review of the methodology and reporting of LCMs in diagnostic accuracy studies. This review shows that the use of LCMs in such studies increased sharply in the past decade, notably in the domain of infectious diseases (overall contribution: 59%).
View Article and Find Full Text PDFBackground: Point-of-care (POC) C-reactive protein (CRP) testing is increasingly used in primary care to assist general practitioners (GPs) in the diagnostic workup for various complaints. The present study compares analytical performance, agreement and user-friendliness of five of these POC CRP tests.
Methods: The following five POC CRP tests were evaluated: Afinion and NycoCard Reader II (both Alere), Eurolyser Smart 700/340 (Eurolyser), QuikRead go and QuikRead 101 (both Orion Diagnostica).
A universal challenge in studies that quantify the accuracy of diagnostic tests is establishing whether each participant has the disease of interest. Ideally, the same preferred reference standard would be used for all participants; however, for practical or ethical reasons, alternative reference standards that are often less accurate are frequently used instead. The use of different reference standards across participants in a single study is known as differential verification.
View Article and Find Full Text PDF