A preconcentration and determination methodology for vanadium at trace levels in parenteral solutions was developed. Cloud point extraction was successfully employed for the preconcentration of vanadium prior to inductively coupled plasma atomic optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) system. The vanadium was extracted as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol [V-(5-Br-PADAP)] complex, at pH 3.
View Article and Find Full Text PDFFour fulvic acid dietary supplement samples were obtained for this study with the intention of investigating the elemental composition and association of fulvic acids found in fulvic acid supplements. This was achieved by coupling size-exclusion chromatography (SEC) sequentially with UV-vis and inductively coupled plasma mass spectrometric (ICP-MS) detectors. The combination of UV and ICP-MS offered highly sensitive and selective detection.
View Article and Find Full Text PDFThe purpose of the current study was to develop a LC-MS(n) method for the analysis of pyrrolizidine alkaloids (PAs) in comfrey. Published data presents an extensive list of PAs and their N-oxides present in comfrey. However, standards are not commercially available for any of the PAs typically present in comfrey.
View Article and Find Full Text PDFA preconcentration and determination method for humic and fulvic acids at trace levels in natural water samples was developed. Cloud point extraction was successfully employed for the preconcentration of humic acid (HA) and fulvic acid (FA) prior to the determination by using a flow injection (FI) system coupled to a spectrophotometric UV-Vis detector. The quantitative extraction of HA and FA within the pH range 1-12 was obtained by neutralization of the anionic charge on the humic substances with a cationic surfactant, hexadecyltrimethylammonium bromide (CTAB).
View Article and Find Full Text PDFAn on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0.
View Article and Find Full Text PDFAn on-line cadmium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated with flow injection was studied. Cadmium was retained as Cd-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Cd-(5-Br-PADAP) complex, pH 9.3.
View Article and Find Full Text PDF