Publications by authors named "Jorge L Alio del Barrio"

Purpose: The purpose of this study was to explore the optimal shape of customized lenticules for stromal lenticule addition keratoplasty (SLAK) for off-centered ectasia.

Methods: Two different methods to create ex vivo models of eccentric-keratoconus were investigated. Twelve human corneas were used to create model 1 by a hyperopic photorefractive keratectomy (PRK), and model 2 by masked phototherapeutic keratectomy (PTK) on the anterior corneal surface, whereas both types received myopic ablation of the posterior surface.

View Article and Find Full Text PDF

Purpose: To manage patient dissatisfaction following multifocal intraocular lens (MF-IOL) implantation by IOL exchange with either a monofocal or an alternative MF-IOL, and to compare outcomes in these two groups.

Methods: MF-IOL exchange was performed in 32 patients (64 eyes) with neuroadaptation failure. The MF-to-MF group involved patients who had a MF-IOL exchanged with another MF-IOL of a different optical profile and the MF-to-MO group involved patients who had a MF-IOL exchanged to a monofocal IOL.

View Article and Find Full Text PDF

Advancements in diagnostic methods and surgical techniques for keratoconus (KC) have increased non-invasive treatment options. Successful surgical planning for KC involves a combination of clinical science, empirical evidence, and surgical expertise. Assessment of disease progression is crucial, and halting the progression should be the focus if it is progressive.

View Article and Find Full Text PDF

The purpose of this study was to describe a case and clinical course of simultaneous anterior chamber phakic intraocular lens (AC-pIOL) removal, implantation of a posterior chamber phakic intraocular implantable collamer lens (ICL), and Descemet membrane endothelial keratoplasty (DMEK). This was a case report of a 44-year-old male with a unilateral decompensated cornea from a displaced Duet-Kelman lens on his left eye that underwent pIOL extraction and implantation of a posterior chamber phakic intraocular ICL and simultaneous DMEK. After 6 months, the cornea of the left eye had regained clarity, the Descemet membrane was graft stable, and the ICL implanted was centered with good vault.

View Article and Find Full Text PDF

This review explores contemporary challenges in penetrating keratoplasty (PK), focusing on technical intricacies, technological advancements, and strategies for preventing graft rejection. A systematic literature search from January 2018 to July 2023 was conducted across PubMed, Cochrane, Web of Science, Scopus, and EMBASE. The inclusion criteria comprised studies on PK and its comparison with other corneal pathologies, with emphasis on keratoconus (KC).

View Article and Find Full Text PDF

Purpose: To assess the efficacy of an automated program for keratoconus and keratoconus suspect detection based on corneal measurements provided by a combined Placido disc and anterior segment optical coherence tomography (OCT) topographer.

Methods: In a multicentric cross-sectional study, an artificial neural network (ANN) was created using 6677 eyes from an equal number of patients (classified as 2663 normal eyes, 1616 keratoconus eyes, 210 keratoconus suspect eyes, 1519 myopic postoperative eyes, and 669 abnormal eyes). Each group was randomly divided into a training set (70% of the dataset) and a validation set (the remaining 30%).

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy of perioperative IPL therapy in preventing postoperative ocular surface disorders in patients undergoing corneal laser refractive surgery.

Design: randomized, controlled, clinical trial with triple-blinding.

Methods: Setting: Vissum Miranza - Alicante; Study population: 61 patients randomized in two groups: 31 study patients (perioperative IPL + laser refractive surgery) and 30 control patients (perioperative placebo + laser refractive surgery).

View Article and Find Full Text PDF

The amniotic membrane is a single epithelial layer of the placenta. It has anti-inflammatory, anti-scarring, anti-angiogenic and possibly bactericidal properties. The basement membrane of the amniotic membrane acts as a substrate to encourage healing and re-epithelialisation.

View Article and Find Full Text PDF

Keratoconus is an ectatic corneal disorder that causes severe vision loss. Surgical options allow us to correct, partially or totally, the induced refractive error. Intracorneal ring segments (ICRS) implantation represents a minimally invasive surgical option that improves visual acuity, with a high success rate and a low overall complication rate.

View Article and Find Full Text PDF

Aim: To report the outcomes of three cases of corneal perforation managed with simultaneous tectonic Descemet stripping endothelial keratoplasty (t-DSEK) and tectonic Bowman layer transplant (t-BLT) as an alternative to tectonic penetrating keratoplasty (t-PKP).

Methods: Three eyes of three patients receiving simultaneous t-DSEK and t-BLT for corneal perforation were included. The technique for DSEK was modified depending on individual requirements.

View Article and Find Full Text PDF

The ectatic disease of the cornea poses a significant challenge for ophthalmologists because commonly used treatments to improve visual acuity, such as spectacles and contact lenses, may not be effective, especially in advanced stages. In addition, the preferred surgical management, corneal transplantation, has various issues related to tissue availability, the steep learning curve, and postoperative complications such as tissue stability and half-life. Ongoing research for an alternative to keratoplasty has suggested various methods, such as corneal crosslinking, which can improve visual function when combined with other techniques.

View Article and Find Full Text PDF

Background: Both the anterior chamber and posterior chamber phakic intraocular lenses (pIOLs) implantation are acceptable refractive surgical approaches in keratoconus patients with high anisometropia, contact lens intolerance, or who prefer spectacle and contact lens independent. They are beneficial for correcting anisometropia in stable keratoconus cases or following corneal procedures such as intrastromal corneal ring segments (ICRS), collagen cross-linking (CXL), and keratoplasty. They are suitable for eyes without advanced keratoconus with acceptable best-corrected distance visual acuity (BCDVA) or without highly irregular astigmatism, high comma, and higher-order aberrations (HOAs).

View Article and Find Full Text PDF

Three-dimensional reconstruction of the corneal surface provides a powerful tool for managing corneal diseases. This study proposes a novel method for reconstructing the corneal surface from elevation point clouds, using modal schemes capable of reproducing corneal shapes using surface polynomial functions. The multivariable polynomial fitting was performed using a non-dominated sorting multivariable genetic algorithm (NS-MVGA).

View Article and Find Full Text PDF

Purpose: To investigate the visual performance after unilateral implantation of an extended depth-of-focus intraocular lens (IOL) in patients with unilateral cataracts.

Methods: In this prospective study, uneventful phacoemulsification with LuxSmart IOL (Bausch & Lomb) implantation was performed in 25 eyes of 25 patients with unilateral cataracts. At postoperative 1, 4, 12, and 24 weeks, uncorrected and corrected visual acuity at far, intermediate, and near distances and the spherical equivalent in manifest refraction were measured.

View Article and Find Full Text PDF

Purpose: To establish a numerical spectral-domain optical coherence tomography (SD-OCT)-based keratoconus (KC) staging system and compare it with existing KC staging systems.

Setting: Eye Hospital of Wenzhou Medical University, Wenzhou, China.

Designs: Retrospective case-control study.

View Article and Find Full Text PDF

Keratoconus is the most common corneal ectatic disorder. It is characterized by progressive corneal thinning with resultant irregular astigmatism and myopia. Its prevalence has been estimated at 1:375 to 1:2,000 people globally, with a considerably higher rate in the younger populations.

View Article and Find Full Text PDF

Purpose: To report the visual and refractive outcomes, intraoperative and postoperative complications, and main causes of bilensectomy in the different types of phakic intraocular lenses (pIOLs).

Methods: This was a retrospective multicenter study that included 234 eyes of 185 patients that underwent bilensectomy. Patients were divided into three groups depending on the pIOL that was explanted (angle-supported, iris-fixated, or posterior chamber).

View Article and Find Full Text PDF

Purpose: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL.

Methods: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm).

View Article and Find Full Text PDF

Purpose: To report modern outcomes of femtosecond laser-assisted cataract surgery (FS-LASIK) for the correction of moderate-to-high hyperopia (≥3.50 diopters [D] and ≤6.50 D), excluding low or very high hyperopia.

View Article and Find Full Text PDF

Purpose: To evaluate the astigmatism tolerance and the visual outcomes after implantation of a premium intraocular lens (IOL) with a continuous transitional focus (Precizon Presbyopic; Ophtec BV) in pseudophakic presbyopia correction.

Methods: This prospective study enrolled 20 patients (40 eyes) after bilateral phacoemulsification and IOL implantation. Corrected and uncorrected visual acuities at 4 m and 80, 67, and 40 cm (CDVA, UDVA, DCI80VA, UI80VA, DCI67VA, UI67VA, DCNVA, and UNVA), astigmatic and spheric defocus curve, mean reading speed (MRS), critical print size (CPS), contrast sensitivity, optical aberrations (modulation transfer function [MTF] cut-off, Strehl ratio, and higher order aberration root mean square [HOA RMS]), objective halometry, and National Eye Institute Refractive Error Quality of Life Instrument 42 [NEI RQL-42] questionnaire were evaluated 3 months after surgery.

View Article and Find Full Text PDF

Background: To compare and contrast morpho-volumetric features between Down syndrome (DS) cornea and non-DS keratoconic cornea by three-dimensional (3D) modelling.

Methods: Forty-three subjects (43 eyes) with DS and 99 patients matching their age and sex (99 eyes) with keratoconus (KC) were included in this single-center cross-sectional study. Main outcome measures were high-order aberrations (HOA), central corneal thickness (CCT), spherical equivalent refraction, and morpho-volumetric parameters established using a 3D corneal model, such as deviation of anterior and posterior corneal apices (D/D) and minimum thickness points (D/D) from corneal vertex, areas of the anterior and posterior surfaces (A/A), sagittal area passing through the anterior and posterior corneal apices (A/A) and minimum thickness point (A) and corneal volume of the complete cornea (V).

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate visual, refractive, quality of vision, visual function and satisfaction of multifocal intraocular lens (MF-IOL) exchange with a monofocal IOL (MNF-IOL) in dissatisfied patients following MF-IOL implantation.

Methods: This was a retrospective case series. Bilateral IOL exchange (MF-IOL to MNF-IOL) was performed in 13 patients (26 eyes) with neuroadaptation failure.

View Article and Find Full Text PDF

Purpose: The aim of this study was to report the corneal densitometry (CD) evolution studied by Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT), and confocal microscopy changes, in patients with advanced keratoconus included in a clinical experience of advanced cell therapy using autologous humans adipose-derived adult stem cells (ADASCs) and corneal decellularized and ADASCs-recellularized human donor corneal laminas.

Methods: This study is an interventional prospective, consecutive, randomized, comparative series of cases. Fourteen patients with keratoconus were randomly distributed into 3 groups for 3 types of surgical interventions: group 1 (G-1), autologous ADASC implantation (n = 5); group 2 (G-2), decellularized human corneal stroma (n = 5); and group 3 (G-3), autologous ADASCs + decellularized human corneal stroma (n = 4).

View Article and Find Full Text PDF

To describe the efficacy and safety of intense pulsed light (IPL) applied directly on the eyelids of patients with Meibomian gland dysfunction (MGD) without corneal shield protector. Observational retrospective single centre study where patients underwent 3 treatment sessions of IPL with 2 weeks of interval. The IPL was carried out with Lumenis OPT M22 with a double pass technique of 12 impacts on the infraorbital/lower eyelid region with the 15 × 35 mm guide light (step 1) and a double pass technique of 3 impacts over the upper eyelids with the 8 × 15 mm guide light (step 2).

View Article and Find Full Text PDF

Purpose: To evaluate the postoperative changes in corneal epithelium thickness and refractive power after femtosecond laser-assisted laser in situ keratomileusis (LASIK) and small incision lenticule extraction (SMILE) for myopia correction using anterior segment optical coherence tomography (OCT) with an integrated Placido disc topographer.

Methods: The VisuMax 500-kHz femtosecond laser (Carl Zeiss Meditec AG) and Amaris 750 excimer laser (SCHWIND eye-tech-solutions) were used. Central, paracentral, and 6-mm epithelial thickness values were obtained, and the change in the value of epithelial thickness was calculated.

View Article and Find Full Text PDF