Statement Of Problem: Intraoral scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the impact of edentulous areas on the accuracy of the MIP located using this AI-based program is unknown.
Purpose: The purpose of this in vitro study was to assess the impact of edentulous areas (0, 1, 2, 3, and 4 posterior mandibular teeth) on the accuracy of the MIP located using 3 intraoral scanners (IOSs) and an AI-based program.
Material And Methods: Stone casts articulated in MIP in an articulator were digitized (T710).
Purpose: To evaluate the accuracy of intraoral scanners (IOSs) for fabricating inlay, onlay, and veneer restorations.
Materials And Methods: A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, Web of Science, and Cochrane. A manual search was also conducted.
Objectives: To measure the influence of scanning pattern on the accuracy, time, and number of photograms of complete-arch intraoral implant scans.
Methods: A maxillary edentulous patient with 7 implants was selected. The reference implant cast was obtained using conventional methods (7Series Scanner).
Statement Of Problem: Multiple factors can influence the accuracy of intraoral scanners (IOSs). However, the impact of scan extension and starting quadrant on the accuracy of IOSs for fabricating tooth-supported crowns remains uncertain.
Purpose: The purpose of the present in vitro study was to measure the influence of scan extension (half or complete arch scan) and the starting quadrant (same quadrant or contralateral quadrant of the location of the crown preparation) on the accuracy of four IOSs.
Statement Of Problem: Maxillary and mandibular scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the accuracy of the AI-based program locating the MIP relationship is unknown.
Purpose: The purpose of the present clinical study was to assess the accuracy of the MIP relationship located by using 4 intraoral scanners (IOSs) and an AI-based program.
Material And Methods: Conventional casts of a participant mounted on an articulator in MIP were digitized (T710).
Statement Of Problem: An artificial-intelligence (AI) based program can be used to articulate scans in maximum intercuspal position (MIP) or correct occlusal collisions of articulated scans at MIP; however, the accuracy of the AI program determining the MIP relationship is unknown.
Purpose: The purpose of the present clinical study was to assess the influence of intraoral scanner (IOS) (TRIOS 5 or i700) and program (IOS or AI-based program) on the accuracy of the MIP relationship.
Material And Methods: Casts of a participant mounted on an articulator were digitized (T710).
BMC Oral Health
February 2024
The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist.Materials and methods Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up.
View Article and Find Full Text PDFPurpose: To measure the impact of the scanning distance on the accuracy of complete-arch implant scans acquired by using a photogrammetry (PG) system.
Material And Methods: An edentulous cast with 6 implant abutment analogs was obtained. A brand new implant scan body was positioned on each implant abutment and digitized using an extraoral scanner (T710; Medit) and the reference file was obtained.
Rehabilitation with dental implants is not always possible due to the lack of bone quality or quantity, in many cases due to bone atrophy or the morbidity of regenerative treatments. We find ourselves in situations of performing dental prostheses with cantilevers in order to rehabilitate our patients, thus simplifying the treatment. The aim of this study was to analyze the mechanical behavior of four types of fixed partial dentures with posterior cantilevers on two dental implants (convergent collar and transmucosal internal connection) through an in vitro study (compressive loading and cyclic loading).
View Article and Find Full Text PDFPurpose: The purpose of the present clinical study was to compare the Ricketts and Steiner cephalometric analysis obtained by two experienced orthodontists and artificial intelligence (AI)-based software program and measure the orthodontist variability.
Materials And Methods: A total of 50 lateral cephalometric radiographs from 50 patients were obtained. Two groups were created depending on the operator performing the cephalometric analysis: orthodontists (Orthod group) and an AI software program (AI group).
J Esthet Restor Dent
February 2024
Objective: The present manuscript describes a technique to virtually switch an implant scan body eliminating the need of obtaining a new intraoral implant digital scan.
Clinical Considerations: Implant scan bodies assist on transferring the 3-dimensional position of the implants into the virtual definitive implant cast. However, if a different implant part is desired during the designing procedures of the implant restoration such as selecting a different implant abutment of varying height, angulation, or manufacturer, a new intraoral implant digital scan with the specific implant scan body is required.
Statement Of Problem: Occlusal collisions of articulated intraoral digital scans can be corrected by intraoral scanners (IOSs) or dental design software programs. However, the influence of these corrections on the accuracy of maxillomandibular relationship is unclear.
Purpose: The purpose of this clinical investigation was to measure the effect of occlusal collision corrections completed by the IOSs or dental design software programs on the trueness and precision of maxillomandibular relationship.
Statement Of Problem: Intraoral scanners (IOSs) have been used in dentistry for diagnostic and treatment purposes; however, the influence of environmental factors such as humidity or temperature on the accuracy of intraoral scanning is uncertain.
Purpose: The purpose of this in vitro study was to evaluate the influence of relative humidity and ambient temperature on the accuracy, scanning time, and number of photograms of dentate complete arch intraoral digital scans.
Material And Methods: A completely dentate mandibular typodont was digitized by using a dental laboratory scanner.
Objectives: To assess the influence of different restorative materials and surface wetness on intraoral scanning accuracy.
Methods: Reference casts with an extracted second premolar and first and second molar were digitized (L2). Four groups were established according to the material of the first molar: natural tooth (control), zirconia (Z), lithium disilicate (LD), and nanoceramic resin crown (NC).
Introduction: To assess the accuracy, repeatability and reproducibility of a measurement digital technique to quantify the wear of the bracket slot walls of the fixed multibracket appliance after orthodontic treatment with the previous measurement traditional technique (scanning electronic microscope (SEM)).
Methods: A total of 100 fixed multibracket appliances were cemented during the 15 months orthodontic treatment and subsequently removed. The fixed multibracket appliances were submitted preoperatively and postoperatively to a micro-computed tomography (micro-CT) scan to obtain accurate standard tessellation language (STL) digital files of the fixed multibracket appliances and to a preoperatively and postoperatively SEM analysis.
Statement Of Problem: Print orientation may affect the manufacturing accuracy of vat-polymerized diagnostic casts. However, its influence should be analyzed based on the manufacturing trinomial (technology, printer, and material) and printing protocol used to manufacture the casts.
Purpose: The purpose of this in vitro study was to measure the influence of different print orientations on the manufacturing accuracy of vat-polymerized polymer diagnostic casts.
BMC Oral Health
December 2022
The aim of this work was to analyze and compare the removal capability, conical internal hex implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws. Twenty abutment screws were randomly fractured into twenty dental implants and randomly extracted using the following removal techniques: Group A: drilling technique without irrigation (n = 10) (DT) and Group B: ultrasonic technique without irrigation (n = 10) (UT). The dental implants were submitted to a preoperative and postoperative micro-computed tomography (micro-CT) scan to obtain a Standard Tessellation Language (STL) digital file that determined the wear comparison by morphometry.
View Article and Find Full Text PDFStatement Of Problem: The accuracy of a maxillomandibular relationship acquired by intraoral scanners (IOSs) has been previously analyzed; however, the impact of the interocclusal space on the accuracy of the maxillomandibular relationship remains unknown.
Purpose: The purpose of this in vitro investigation was to evaluate the influence of the interocclusal space (0, 1, 2, 3, or 4 degrees of incisal opening in the articulator) on the accuracy of the maxillomandibular relationship captured with an IOS.
Material And Methods: Markers were attached to the first molars and canines of maxillary and mandibular diagnostic casts, which were mounted on a semi-adjustable articulator, and digital scans were acquired (TRIOS 4).
Purpose: The airway complex is modified by palatine expansion. Computer tomography has been used in the past to determine the change in volume, but there was a lack of a specific, reproducible method for this purpose. The present study sought to determine the accuracy, reproducibility, and repeatability of an innovative digital measurement technique for analyzing the volume of maxillary and nasal sinus airways following suture palatine expansion performed with the Hyrax disyuntor appliance.
View Article and Find Full Text PDF