Objective: Dosing errors can cause significant harm in paediatric healthcare settings. Our objective was to investigate the effects of paediatric dose range checking (DRC) clinical decision support (CDS) software on overdosing-related outcomes.
Methods: A before-after study and a semistructured survey of prescribers was conducted across inpatient wards (excluding intensive care) in a regional children's hospital.