Purpose: To determine the frequency and outcome of additionally detected ipsilateral breast abnormalities following recall at screening mammography.
Methods And Materials: We included a consecutive series of 130,338 screening mammograms obtained between January 1, 2014 and January 1, 2016. During 2-year follow-up, clinical data were collected of all recalls.