Publications by authors named "Joost H J van Erp"

Femoral component orientation plays a key role in implant stability and therefore the success rate of total hip arthroplasty. To date, this topic has been studied using various definitions and a variety of imaging modalities and protocols. The aim of this study is a proof of concept that a new algorithm can be used to describe the femoral component's 3D orientation on the three orthogonal anatomical planes and relative to its mechanical axis using input from two orthogonal planes.

View Article and Find Full Text PDF

Introduction: Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability.

View Article and Find Full Text PDF

Aims: The aetiologies of common degenerative spine, hip, and knee pathologies are still not completely understood. Mechanical theories have suggested that those diseases are related to sagittal pelvic morphology and spinopelvic-femoral dynamics. The link between the most widely used parameter for sagittal pelvic morphology, pelvic incidence (PI), and the onset of degenerative lumbar, hip, and knee pathologies has not been studied in a large-scale setting.

View Article and Find Full Text PDF

Background and purpose - Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linked polyethylene (HXLPE) cup was developed. This study set out to compare the wear and clinical 6-year outcomes of vitamin E blended HXLPE with UHMWPE in an isoelastic monoblock cup in patients with hip osteoarthritis who underwent uncemented THA.

View Article and Find Full Text PDF

Case: An 84-year old woman developed 2 large seromal cysts at the medial side of her right thigh, 4 months after total knee arthroplasty (TKA). The cysts were located at the place where the tourniquet, during surgery, had been applied. The diagnosis was confirmed with echography and magnetic resonance imaging.

View Article and Find Full Text PDF

- The long-term survival of arthroplasty components may be limited by polyethylene wear-related problems such as periprosthetic osteolysis and aseptic loosening. Highly cross-linked polyethylene (HXLPE) blended with vitamin E was introduced to improve oxidative stability and to avoid long-term embrittlement. This study clinically compares the tribological behavior and clinical outcome of vitamin E blended HXLPE with ultra-high molecular weight polyethylene (UHMWPE) in an isoelastic monoblock cup for uncemented total hip arthroplasty.

View Article and Find Full Text PDF

Background and purpose - The preferred treatment of an acute prosthetic joint infection (PJI) is debridement, antibiotics, irrigation and retention of the prosthesis (DAIR). The antibiotic treatment consists of an empirical and targeted phase. In the empirical phase, intravenous antibiotics are started after surgery before micro-organisms are determined in microbiological cultures.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) is a very successful procedure in orthopedics. Still polyethylene wear and gait deficits are limiting the clinical success.It is important to reconstruct leg length (LL) and femoral offset (FO) anatomically in order to have the best possible result of a THA.

View Article and Find Full Text PDF