. Although recent studies have shown that mechanical stress plays an important role in ultrasound neuromodulation, the magnitude and distribution of the mechanical stress generated in tissues by focused ultrasound transducers have not been adequately examined. Various acoustic radiation force (ARF) equations used in previous studies have been evaluated based on the tissue displacement results and are suitable for estimating the displacement.
View Article and Find Full Text PDFSensors (Basel)
February 2023
Interest in underwater transducers has persisted since the mid-1900s. Underwater transducers are designed in various shapes using various materials depending on the purpose of use, such as to achieve high power, improve broadband, and enhance beam steering. Therefore, in this study, an analysis is conducted according to the structural shape of the transducer, exterior material, and active material.
View Article and Find Full Text PDFThis paper presents a control technique for reducing the reflection of acoustic signals for the plane array of multilayer acoustic absorbers underwater. In order to achieve this, a plane array of multilayer acoustic absorbers is proposed to attenuate low-frequency noise, with each unit consisting of a piezoelectric transducer, two layers of polyvinylidene fluorides and three layers of the acoustic window. Time-delay separation is used to find the incident and reflected acoustic signals to achieve reflected sound reduction.
View Article and Find Full Text PDFTechniques for reducing the reflection of acoustic signals have recently been actively studied. Most methods for reducing acoustic signals were studied using the normal-incidence wave reduction technique. Although the technique of canceling an object from the normal incidence wave is essential, research on reducing acoustic signals according to the angle of incidence is required for practical applications.
View Article and Find Full Text PDFIn this study, piezoelectric acoustic absorbers employing two receivers and one transmitter with a feedback controller were evaluated. Based on the target and resonance frequencies of the system, resonance and non-resonance models were designed and fabricated. With a lateral size less than half the wavelength, the model had stacked structures of lossy acoustic windows, polyvinylidene difluoride, and lead zirconate titanate-5A.
View Article and Find Full Text PDFWith the development of wearable devices, strain sensors have attracted large interest for the detection of human motion, movement, and breathing. Various strain sensors consisting of stretchable conductive materials have been investigated based on resistance and capacitance differences according to the strain. However, this method requires multiple electrodes for multipoint detection.
View Article and Find Full Text PDFIntensive research on photoacoustics (PA) for imaging of the living human body, including the skin, vessels, and tumors, has recently been conducted. We propose a PA measurement system based on a capacitive micromachined ultrasonic transducer (CMUT) with waterless coupling, short measurement time (<1 s), backward light irradiation, and a low-profile ultrasonic receiver unit (<1 cm). We fabricate a 64-element CMUT ring array with 6.
View Article and Find Full Text PDF