Workers in occupational settings are usually exposed to numerous sources of electromagnetic fields (EMF) and to different physical agents. Risk assessment for industrial workplaces concerning EMF is not only relevant to operators of devices or machinery emitting EMF, but also to support-workers, bystanders, service and maintenance personnel, and even visitors. Radiofrequency EMF guidelines published in 2020 by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) may also be indirectly applied to assess risks emerging from EMF sources at workplaces by technical standards or legislation.

View Article and Find Full Text PDF

Objectives: We explored the prevalence of health complaints subjectively associated with static magnetic field (SMF) and acoustic noise exposure among MR radiographers in Sweden, using CT radiographers as a control group. Additionally, we explored radiographers' use of strategies to mitigate adverse health effects.

Methods: A cross-sectional survey was sent to all hospitals with MR units in Sweden.

View Article and Find Full Text PDF

Background: MR-generated acoustic noise can contribute to patient discomfort and potentially be harmful. One way to reduce this noise is by altering the gradient output and/or waveform using software optimization. Such modifications might influence image quality and switched gradient field exposure, and different techniques appear to affect sound pressure levels (SPLs) to various degrees.

View Article and Find Full Text PDF

Several in vitro and in vivo studies have investigated if a magnetic resonance imaging (MRI) examination can cause DNA damage in human blood cells. However, the electromagnetic field (EMF) exposure that the cells received in the MR scanner was not sufficiently described. The first studies looking into this could be regarded as hypothesis-generating studies.

View Article and Find Full Text PDF

Objectives: The objectives were to survey MR safety incidents in Sweden during a 12-month period, to assess severity scores, and to evaluate the confidence of MR personnel in incident-reporting mechanisms.

Method: Data were collected within a web-based questionnaire on safety in clinical MR environments with CT for comparison. Data reported MR and CT safety incidents (human injury, material damage, and close calls), incident severity, and confidence of participants in incident-reporting systems.

View Article and Find Full Text PDF

The main aim of the study was to identify and describe methods using non-ionizing radiation (NIR) such as electromagnetic fields (EMF) and optical radiation in Swedish health care. By examining anticipated exposure levels and by identifying possible health hazards we also aimed to recognize knowledge gaps in the field. NIR is mainly used in health care for diagnosis and therapy.

View Article and Find Full Text PDF

The objective of this study was to evaluate occurrence and strength of short-term effects experienced by study participants in an actively shielded (AS) 7 tesla (7 T) magnetic resonance (MR) scanner, to compare results with earlier reports on passively shielded (PS) 7 T MR scanners, and to outline possible healthcare strategies to improve patient compliance. Study participants (n = 124) completed a web-based questionnaire directly after being examined in an AS 7 T MR (n = 154 examinations). Most frequently experienced short-term effects were dizziness (84%) and inconsistent movement (70%), especially while moving into or out of the magnet.

View Article and Find Full Text PDF

The magnetic resonance imaging (MRI) exposure environment is unique due to the mixture and intensity of magnetic fields involved. Current safety regulations are based on well-known acute effects of heating and neuroexcitation while the scientific grounds for possible long-term effects from MRI exposure are lacking. Epidemiological research requires careful exposure characterization, and as a first step toward improved exposure assessment we set out to characterize the MRI-patient exposure environment.

View Article and Find Full Text PDF

A complex mixture of electromagnetic fields is used in magnetic resonance imaging (MRI): static, low-frequency, and radio frequency magnetic fields. Commonly, the static magnetic field ranges from one to three Tesla. The low-frequency field can reach several millitesla and with a time derivative of the order of some Tesla per second.

View Article and Find Full Text PDF

As a case study we have measured the magnetic field from an induction loop pad designed for hearing aid assistance. The magnitude of the field was high, although well below international guidelines. We recorded values up to 70% of the recommended standard in some instances.

View Article and Find Full Text PDF

Knowledge of patient exposure during magnetic resonance imaging (MRI) procedures is limited, and the need for such knowledge has been demonstrated in recent in vitro and in vivo studies of the genotoxic effects of MRI. This study focuses on the dB/dt of the switched gradient field (SGF) and its geometric distribution. These values were characterized by measuring the peak dB/dt generated by a programmed gradient current of alternating triangles inside a 1.

View Article and Find Full Text PDF

We estimate that there are about 100,000 workers from different disciplines, such as radiographers, nurses, anesthetists, technicians, engineers, etc., who can be exposed to substantial electromagnetic fields (compared to normal background levels) around magnetic resonance imaging (MRI) scanners. There is a need for well-designed epidemiological studies of MRI workers but since the exposure from MRI equipment is a very complex mixture of static magnetic fields, switched gradient magnetic fields, and radiofrequency electromagnetic fields (RF EMF), it is necessary to discuss how to assess the exposure in epidemiological studies.

View Article and Find Full Text PDF

A questionnaire-based descriptive pilot study was conducted among all nurses routinely working with MRI in the Northern part of Sweden to provide an indication of the self-reported prevalence of health complaints related to working with MRI systems. Fifty-nine nurses (88% response rate), with on average 8 (±6) years experience with MRI scanning procedures, returned the questionnaire. In total, 9 nurses (15%) reported regularly experiencing at least one of the health complaints (1-5% for specific health complaints) attributed to arise or be aggravated by their presence in the MRI scanning room.

View Article and Find Full Text PDF

Electrosurgical units (ESU) are widely used in medical health services. By applying sinusoidal or pulsed voltage in the frequency range of 0.3-5 MHz to the electrode tip, the desired mixture of coagulation and cutting are achieved.

View Article and Find Full Text PDF

The gradient fields in magnetic resonance imaging (MRI) will in some circumstances exceed the ICNIRP guidelines of occupational electromagnetic field exposure when personnel are near the scanner during MRI scanning. In this work we have shown that using commercially available modified sequences for noise reduction purposes, exposure will decrease by a factor of 1.5 with preserved image quality.

View Article and Find Full Text PDF

Extremely low frequency (ELF) magnetic fields in cell culture incubators have been measured. Values of the order of tens of muT were found which is in sharp contrast to the values found in our normal environment (0.05-0.

View Article and Find Full Text PDF

This study investigates the effect of exposure to a mobile phone-like radiofrequency (RF) electromagnetic field on people with atopic dermatitis (AD). Fifteen subjects with AD were recruited and matched with 15 controls without AD. The subjects were exposed for 30 min to an RF field at 1 W/kg via an indoor base station antenna attached to a 900 MHz GSM mobile phone.

View Article and Find Full Text PDF

The frequency spectra of electromagnetic fields have to be determined to evaluate human exposure in accordance to ICNIRP guidelines. In the literature, comparisons with magnetic field guidelines have been performed by using the frequency distribution of the current drawn from the battery. In the present study we compared the frequency spectrum in the range 217 Hz to 2.

View Article and Find Full Text PDF

In a previous study, we showed that operators of radiofrequency (RF) plastic sealers, RF operators (n = 35) had a lower heart rate during nighttime compared to a control group (n = 37). We have analyzed the heart rate variability (HRV) on the same group of people to better understand the possible underlying rhythm disturbances. We found a significantly increased total HRV and very low frequency (VLF) power during nighttime among the RF operators compared to a control group.

View Article and Find Full Text PDF

The aim of the present study was to investigate the effect of exposure to a mobile phone-like radiofrequency (RF) electromagnetic field on persons experiencing subjective symptoms when using mobile phones (MP). Twenty subjects with MP-related symptoms were recruited and matched with 20 controls without MP-related symptoms. Each subject participated in two experimental sessions, one with true exposure and one with sham exposure, in random order.

View Article and Find Full Text PDF

Operators of RF plastic sealers (RF operators) are an occupational category highly exposed to radiofrequency electromagnetic fields. The aim of the present study was to make an appropriate exposure assessment of RF welding and examine the health status of the operators. In total, 35 RF operators and 37 controls were included.

View Article and Find Full Text PDF

In a previous epidemiological study, where we studied the prevalence of subjective symptoms among mobile phone (MP) users, we found as an interesting side finding that the prevalence of many of the subjective symptoms increased with increasing calling time and number of calls per day. In this extrapolative study, we have selected 2402 people from the epidemiological study who used any of the four most common GSM MP. We used the information about the prevalence of symptoms, calling time per day, and number of calls per day and combined it with measurements of the Specific Absorption Rate (SAR).

View Article and Find Full Text PDF