Publications by authors named "JongShill Lee"

Transcutaneous auricular vagus nerve stimulation (taVNS), a non-invasive method of stimulating the vagus nerve, simultaneously affects the autonomic nervous system (ANS) and central nervous system (CNS) through efferent and afferent pathways. The purpose of this study is to analyze the effect of taVNS on the ANS and CNS through heart rate variability (HRV) and electroencephalography (EEG) parameters of identified responders.Two sets of data were collected from each of 10 healthy adult male subjects in their 20 s, and five HRV parameters from the time domain (RMSSD, pNN50, pNN30, pNN20, ppNNx) and two EEG parameters (power of alpha band, power of delta band) were extracted.

View Article and Find Full Text PDF

In modern society, the popularity of wearable devices has highlighted the need for data security. Bio-crypto keys (bio-keys), especially in the context of wearable devices, are gaining attention as a next-generation security method. Despite the theoretical advantages of bio-keys, implementing such systems poses practical challenges due to their need for flexibility and convenience.

View Article and Find Full Text PDF

Gaming disorder (GD) is an addictive behavior characterized by an insatiable need to play video games and shares similar symptoms with the failure of self-control due to a decline in cognitive function. Current GD diagnostic and screening tools rely on questionnaires and behavioral observations related to cognitive functions to assess an individual's capacity to maintain self-control in everyday life. However, current GD screening approaches rely on subjective symptoms, and a reliable diagnosis requires long-term clinical follow-up.

View Article and Find Full Text PDF

Pulse arrival time (PAT) and PPG morphological features have attracted much interest in cuffless blood pressure (BP) estimation, but their effects are not clearly understood when vascular characteristics are affected by diseases such as diabetes. This work quantitatively analyzes the effect of diabetic disease on the PAT and PPG morphological features-based BP estimation. We selected 112 diabetic patients and 308 non-diabetic subjects from VitalDB, and extracted 16 features including PAT, PPG morphological features, and heart rate.

View Article and Find Full Text PDF

Mental stress is on the rise as one of the major health problems in modern society. It is important to detect and manage mental stress to prevent various diseases caused by stress and to maintain a healthy life. The purpose of this paper is to present new heart rate variability (HRV) features based on empirical mode decomposition and to detect acute mental stress through short-term HRV (5 min) and ultra-short-term HRV (under 5 min) analysis.

View Article and Find Full Text PDF

: This study analyzed the prognostic impact of mechanical cardiopulmonary resuscitation (CPR) devices in out-of-hospital cardiac arrest (OHCA) patients, in comparison to manual CPR. : This study was a nationwide population-based observational study in South Korea. Data were retrospectively collected from 142,905 OHCA patients using the South Korean Out-of-Hospital Cardiac Arrest Surveillance database.

View Article and Find Full Text PDF

The development and use of wearable devices require high levels of security and have sparked interest in biometric authentication research. Among the available approaches, electrocardiogram (ECG) technology is attracting attention because of its strengths in spoofing. However, morphological changes of ECG, which are affected by physical and psychological factors, can make authentication difficult.

View Article and Find Full Text PDF

This study aimed to assess the effectiveness of a novel chest compression (CC) smart-ring-based feedback system in a manikin simulation. In this randomized, crossover, controlled study, we evaluated the effect of smart-ring CC feedback on cardiopulmonary resuscitation (CPR). The learnability and usability of the tool were evaluated with the System Usability Scale (SUS).

View Article and Find Full Text PDF

Objective: An objective and convenient primary triage procedure is needed for prioritizing patients who need help in mass casualty incident (MCI) situations, where there is a lack of medical staff and available resources. This study aimed to develop an automated remote decision-making algorithm that remotely categorize a patient's emergency level using clinical parameters that can be measured with a wearable device.

Approach: The algorithm was developed according to the following procedures.

View Article and Find Full Text PDF

Recently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the relationship between hip and knee joint movements in patients with knee osteoarthritis (KOA) using hip-knee cyclograms to assess coordination and gait variability.
  • It includes 50 KOA patients divided into early (20) and advanced (30) stages, along with 26 healthy participants over 50 years old for comparison.
  • Findings reveal that KOA severity leads to reduced knee range of motion, decreased movement area during walking, and greater variability in gait patterns, particularly pronounced in advanced KOA patients.
View Article and Find Full Text PDF

Hand functions affect the instrumental activities of daily living. While functional outcome measures, such as a targeted box and block test, have been widely used in clinical settings and provide a useful measure of overall performance, the advent of a wearable Inertial Measurement Unit(IMU)-based system enables the examination of the specific performance and kinematic parameters of hand movements. This study proposed a novel clip-on IMU system to facilitate the clinically fitted measurements of fine-motor finger and wrist joint movements.

View Article and Find Full Text PDF

Objective: To investigate the feasibility of mobile videocall guidance to facilitate AED use by laypersons. . A total of 90 laypersons were randomized into three groups: the mobile video call-guided, voice call-guided, and non-guided groups.

View Article and Find Full Text PDF

Musical cueing has been widely utilised in post-stroke motor rehabilitation; however, the kinematic evidence on the effects of musical cueing is sparse. Further, the element-specific effects of musical cueing on upper-limb movements have rarely been investigated. This study aimed to kinematically quantify the effects of no auditory, rhythmic auditory, and melodic auditory cueing on shoulder abduction, holding, and adduction in patients who had experienced hemiparetic stroke.

View Article and Find Full Text PDF

Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA).

View Article and Find Full Text PDF

Measuring blood pressure (BP) at home and remote monitoring can improve the patient's adherence to BP control and vascular outcomes. This study evaluated the feasibility of a trial regarding the effects of an intensive mobile BP management strategy versus usual care in acute ischemic stroke patients. A feasibility-testing, randomized, open-labeled controlled trial was conducted.

View Article and Find Full Text PDF

In a mass casualty incident, the factors that determine the survival rate of injured patients are diverse, but one of the key factors is the time for triage. Additionally, the main factor that determines the time of triage is the number of medical personnel. However, when relying on a small number of medical personnel, the ability to increase survivability is limited.

View Article and Find Full Text PDF

Internet gaming disorder (IGD) is characterized by a loss of control over gaming and a decline in psychosocial functioning derived from excessive gameplay. We hypothesized that individuals with IGD would show different autonomic nervous system (ANS) responses to the games than those without IGD. In this study, heart rate variability (HRV) was assessed in 21 young males with IGD and 27 healthy controls while playing their favorite Internet game.

View Article and Find Full Text PDF

Generalized tonic-clonic seizures (GTCSs) can be underestimated and can also increase mortality rates. The monitoring devices used to detect GTCS events in daily life are very helpful for early intervention and precise estimation of seizure events. Several studies have introduced methods for GTCS detection using an accelerometer (ACM), electromyography, or electroencephalography.

View Article and Find Full Text PDF

The purpose of the study is to analyse how the standard of resting metabolic rate (RMR) affects estimation of the metabolic equivalent of task (MET) using an accelerometer. In order to investigate the effect on estimation according to intensity of activity, comparisons were conducted between the 3.5 ml O · kg · min and individually measured resting VO as the standard of 1 MET.

View Article and Find Full Text PDF

The aim of this study was to investigate how the interrelationships between low-frequency oscillations (LFOs) in the cerebral and systemic cardiovascular hemodynamic systems change with aging and systemic hemodynamic perturbation. Seventeen young adult (28.4±3.

View Article and Find Full Text PDF

Objectives: This study describes the development of a new digital sphygmocorder (DS-II), which allows the digital recording and playback of the Korotkoff sounds, together with cuff pressure waveform, and its performance in a pilot validation study.

Materials And Methods: A condenser microphone and stethoscope head detect Korotkoff sounds and an electronic chip, dedicated to audio-signal processing, is used to record high-quality sounds. Systolic and diastolic blood pressure (SBP/DBP) are determined from the recorded signals with an automatic beat detection algorithm that displays the cuff pressure at each beat on the monitor.

View Article and Find Full Text PDF

To supply proper treatments to the primary blast lung injury (PBLI) patients, it is important to estimate the severity of the primary blast lung injury in accordance with the blast conditions. In this study, a blast-induced mechanical parameter (first principal stress) of lung was calculated using a finite element thorax model and the correlation between the survival rate of the subjects with blast-induced lung damage and an objective index that was related to the first principal stress of the lung model. This study propose the objective index for the estimation of the degree of PBLI.

View Article and Find Full Text PDF

Objective: The auscultatory method is influenced by the hearing level of the observers. If the observer has hearing loss, it is possible to measure blood pressure inaccurately by misreading the Korotkoff sounds at systolic blood pressure (SBP) and diastolic blood pressure (DBP). Because of the potential clinical problems this discrepancy may cause, we used a hearing loss simulator to determine how hearing level affects the accuracy of blood pressure measurements.

View Article and Find Full Text PDF