Long-term exposure to volatile organic compounds (VOCs) and carbonyl compounds in beauty products may adversely impact the health of beauty salon technicians. Previous studies have focused on assessing indoor air concentrations of chemicals, such as benzene and toluene, and not on personal exposure concentrations. This study measured the indoor and personal exposure concentrations of VOCs and carbonyl compounds in fifty-three beauty salons in Korea.
View Article and Find Full Text PDFInt J Environ Res Public Health
October 2020
IoT-based monitoring devices can transmit real-time and long-term thermal environment data, enabling innovative conversion for the evaluation and management of the indoor thermal environment. However, long-term indoor thermal measurements using IoT-based devices to investigate health effects have rarely been conducted. Using apartments in Seoul as a case study, we conducted long-term monitoring of thermal environmental using IoT-based real-time wireless sensors.
View Article and Find Full Text PDFInt J Environ Res Public Health
October 2020
Indoor microbiological air quality, including airborne bacteria and fungi, is associated with hospital-acquired infections (HAIs) and emerging as an environmental issue in hospital environment. Many studies have been carried out based on culture-based methods to evaluate bioaerosol level. However, conventional biomonitoring requires laborious process and specialists, and cannot provide data quickly.
View Article and Find Full Text PDFInt J Environ Res Public Health
November 2019
The scale of the damage due to chemical accidents in Korea is significant, and appropriate preparation and response are required. Currently, Korean enterprises are managed on the basis of the presence of certain substances. However, chemicals other than these also cause chemical accidents.
View Article and Find Full Text PDFRecently, new virus-based sensor systems that operate on M13 bacteriophage infrastructure have attracted considerable attention. These systems can detect a range of chemicals with excellent sensitivity and selectivity. Filaments consistent with M13 bacteriophages can be ordered by highly established forms of self-assembly.
View Article and Find Full Text PDFInt J Environ Res Public Health
September 2019
To reduce damage caused by chemical accidents, it is important to establish a prevention system for chemical accidents. The first step in the prevention of chemical accidents is to screen the high-risk chemical plants. Risk index, one of the screening methods, can indirectly estimate the risk at each chemical plant.
View Article and Find Full Text PDFThis study aims to provide a new methodology using the Globally Harmonized System (GHS) and the Mahalanobis-Taguchi System (MTS) that can be used to assess the overall hazard of a chemical using GHS information. Previously, hazardous chemicals were designated and managed by the Chemical Management Act, but many more chemicals are now in use. Damage prediction modeling programs predict the extent of damage and proactively manage high-risk chemicals, but the lack of physical and chemical characterization information relating to chemicals has limitations that cannot be modeled.
View Article and Find Full Text PDFFacilities for sensitive populations have increased in Korea; and its indoor air quality (IAQ) was strictly regulated by the Korean government compared to other facilities. However, merely public facilities on certain level of total floor area were lawfully regulated. This study aims to characterize the indoor environment at facilities for sensitive populations in Korea and investigate the effects of legal regulation on IAQ throughout the duration of 1 year.
View Article and Find Full Text PDFIndoor air quality (IAQ) is one of important issues in indoor environment due to exposure to inhalable aerosol which is affected by indoor and outdoor factors. To demonstrate the effect of indoor and outdoor to the IAQ, this study presents three fractions of particulate matter (PM) (PM, PM, PM), characterization of I/O ratios for PM under potential indoor (average occupancy) and outdoor factors (Asian dust, rain, wind, and snow days) and evaluation of chemical components in aerosols. In the chemical characteristics of PM, organic carbon (OC), elemental carbon (EC), and trace elements were analyzed in indoors and outdoors.
View Article and Find Full Text PDFIn this research, the concentrations of six heavy metals (Zn, Pb, Ni, Fe, Cd, and Cr) in electronic cigarette (EC) solutions were determined to assess their association with EC use patterns. To this end, their contents were analyzed under three conditions: (1) ECL I: EC liquid was directly taken from EC liquid bottles as purchased from retail, (2) ECL II: EC liquid simply stored in the EC clearomizer for a certain period was collected without any puffing, and (3) ECL III: EC liquid remaining in the EC clearomizer after puffing. Each of all three types of electronic cigarette liquid (ECL) samples selected in this study was analyzed after being stored for up to seven days (at elapsed intervals of 1, 3, and 7 days).
View Article and Find Full Text PDFInt J Environ Res Public Health
March 2019
Benzene, toluene, and xylene (BTX) are flammable substances used in a wide range of raw materials and products. Chemical accidents caused by flammable substances are different from leakage accidents of toxic materials. Initial explosions and fires may cause secondary or tertiary explosions, or fires with nearby flammable materials.
View Article and Find Full Text PDFInt J Environ Res Public Health
January 2019
Audiol Neurootol
September 2019
Previous studies have reported that exposure to lead and cadmium can damage the inner ear receptor, which perceives high-frequency sounds. However, few studies have used the pure-tone average (PTA), including high-frequency ranges, for the estimation of hearing loss caused by lead and cadmium exposure. We estimated hearing loss using the PTA test, in low-frequency, speech frequency, and high-frequency ranges and compared the differences in the results using 3 PTA calculation methods.
View Article and Find Full Text PDFInt J Environ Res Public Health
October 2018
For efficient management of chemicals, it is necessary to preferentially select hazardous chemicals as being high-priority through a screening method. Over the past 20 years, chemical ranking and scoring (CRS) methods have been applied in many countries; however, these CRS methods have a few limitations. Most of the existing methods only use some of the variables to calculate the hazard of chemicals or use the most conservative score without consideration of the correlation between chemical toxicities.
View Article and Find Full Text PDFInt J Environ Res Public Health
July 2018
Unlike other countries, the Korean chemical industry does not clearly distinguish between industrial sites and residential areas. The 2012 Gumi Hydrogen Fluoride Accident revealed that chemical accidents could cause damage to nearby residents. Accordingly, the Chemicals Control Act was enacted in 2015, which requested industrial sites using chemicals to perform a risk assessment for all chemical facilities and to distribute the results to the local residents and governments.
View Article and Find Full Text PDFInt J Environ Res Public Health
May 2018
We studied sensitive weather variables for consequence analysis, in the case of chemical leaks on the user side of offsite consequence analysis (OCA) tools. We used OCA tools Korea Offsite Risk Assessment (KORA) and Areal Location of Hazardous Atmospheres (ALOHA) in South Korea and the United States, respectively. The chemicals used for this analysis were 28% ammonia (NH₃), 35% hydrogen chloride (HCl), 50% hydrofluoric acid (HF), and 69% nitric acid (HNO₃).
View Article and Find Full Text PDFA mechanical pencil lead (MPL), an easily obtainable carbon-based material with a consistent size, was used as a frame to construct an MPL-supported carbon nanotube/Au nanodendrite (MPL-CNT/AuND) sensor through simple electrodeposition of Au onto the MPL in the presence of CNTs. A nanodendrite structure was adopted to ensure large numbers of active electrochemical sites because of its hierarchical structure with well-aligned terraces; the CNTs were used to firmly adhere the fabricated Au nanodendrites to the MPL surface to ensure ruggedness. The MPL-CNT/AuND structure was used to measure As samples in a concentration range from 0.
View Article and Find Full Text PDFParticulate matter (PM) in buildings are mostly sourced from the transport of outdoor particles through a heating, ventilation, and air conditioning (HVAC) system and generation of particle within the building itself. We investigated the concentrations and characteristic of indoor and outdoor particles and airborne bacteria concentrations across four floors of a building located in a high-traffic area. In all the floors we studied (first, second, fifth, and eighth), the average concentrations of particles less than 10 μm (PM10) in winter for were higher than those in summer.
View Article and Find Full Text PDFThe emission rates of N,N-dimethylformamide (DMF), formamide (FAd), and certain hazardous volatile organic compounds (VOCs) were measured from seventeen mattress textile samples with four different raw material types: polyurethane (PU: n=3), polyester/polyethylene (PE: n=7), ethylene vinyl acetate (EV: n=3), and polyvinyl chloride (PC: n=4). To simulate the emissions in a heated room during winter season, measurements were made under temperature-controlled conditions, i.e.
View Article and Find Full Text PDFThe relative performance of different sorbent materials employed in the cryofocusing (e.g. in cold trap (CT) unit) stage was investigated at sub-ambient temperature by the thermal desorption (TD)-gas chromatography (GC)-pulsed flame photometric detector.
View Article and Find Full Text PDFPeroxyacetyl nitrate (PAN) in air has been well known as the indicator of photochemical smog due to its frequent occurrences in Seoul metropolitan area. This study was implemented to assess the distribution characteristics of atmospheric PAN in association with relevant parameters measured concurrently. During a full year period in 2011, PAN was continuously measured at hourly intervals at two monitoring sites, Gwang Jin (GJ) and Gang Seo (GS) in the megacity of Seoul, South Korea.
View Article and Find Full Text PDFTo describe the fundamental aspects of air quality in tunnel environments, field campaigns were conducted to measure polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs), and some criteria pollutants from two tunnel sites of Nam San (NS) and Hong Ji (HJ) gates in Seoul, Korea. The total PAH values (ngm(-3)) for the NS tunnel (137.8 +/- 10.
View Article and Find Full Text PDFIn this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated.
View Article and Find Full Text PDFWhole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar(®)) bags for gaseous VOC sampling. Eight VOC standards (benzene, toluene, p-xylene, styrene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol) were placed into each bag at storage times of 0, 2, and 3 days prior to analyses by gas chromatography/mass spectrometry (GC/MS).
View Article and Find Full Text PDFObjects: The prevalence of asthma has increased in recent decades globally. The objective of the present study is to elucidate whether hospitalization for bronchiolitis in infancy and low socioeconomic status interact for bronchial hyperreactivity during teenage years.
Method: We studied 522 children age 13-14 years attending schools in rural and urban areas to investigate the risk factors for bronchial hyperreactivity (BHR), defined as a provocation concentration of methacholine that causes a decrease of 20% (PC(20)) in forced expiratory volume within 1 second.