Publications by authors named "Jonelle Thompson"

The PowerPlex Y23 System offered by Promega Corporation contains 23 Y-STR loci (DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS481, DYS533, DYS549, DYS570, DYS576, DYS635, DYS643, and Y-GATA-H4). The PowerPlex Y23 System is designed to amplify DNA from purified extracts as well as direct amplification from substrates used to collect database samples (e.g.

View Article and Find Full Text PDF

Quantification of the total amount of human DNA isolated from a forensic evidence item is crucial for DNA normalization prior to short tandem repeat (STR) DNA analysis and a federal quality assurance standard requirement. Previous commercial quantification methods determine the total human DNA and total human male DNA concentrations, but provide limited information about the condition of the DNA sample. The PowerQuant(®) System includes targets for quantification of total human and total human male DNA as well as targets for evaluating whether the human DNA is degraded and/or PCR inhibitors are present in the sample.

View Article and Find Full Text PDF

The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems.

View Article and Find Full Text PDF

The PowerPlex® Y23 System combines the seventeen Y-STR loci in current commercially available Y-STR kits (DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS635, and Y-GATA-H4) with six new highly discriminating Y-STR loci (DYS481, DYS533, DYS549, DYS570, DYS576, and DYS643). These six new loci have higher gene diversities than most of the loci in other commercial Y-STR analysis kits, allowing for further distinction between unrelated male individuals. In addition, the inclusion of two rapidly mutating Y-STR loci may allow for the discrimination of related individuals.

View Article and Find Full Text PDF

The Prototype PowerPlex(®) Y23 System (Promega Corporation, Madison, WI) is a polymerase chain reaction-based amplification kit that targets the 23 Y STR loci DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS481, DYS533, DYS549, DYS570, DYS576, DYS635, DYS643, and Y-GATA-H4. A total of 951 samples from six populations were typed to evaluate the kit and examine concordance for 17 of the loci that are in common with those that can be typed using the AmpFlSTR(®) Yfiler™ kit (Life Technologies, Carlsbad, CA). A total of 16,167 loci were analyzed for each multiplex, and overall concordance was observed.

View Article and Find Full Text PDF

We describe the developmental validation study performed on the PowerPlex(®) ESX 16 (European Standard Extended 16) and the PowerPlex(®) ESX 17 Systems, part of a suite of four new DNA profiling kits developed by Promega in response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. The PowerPlex(®) ESX 16 System combines the 11 loci compatible with the UK National DNA Database, contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to incorporate these five new loci as mini- and midi-STRs while maintaining the loci found in the AmpFlSTR(®) SGM Plus(®) kit as standard size.

View Article and Find Full Text PDF

In response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe, Promega(®) developed a suite of four new DNA profiling kits. This paper describes the developmental validation study performed on the PowerPlex(®) ESI 16 (European Standard Investigator 16) and the PowerPlex(®) ESI 17 Systems. The PowerPlex(®) ESI 16 System combines the 11 loci compatible with the UK National DNA Database(®), contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391.

View Article and Find Full Text PDF

STR multiplexes remain the cornerstone of genotyping forensic samples. The PowerPlex 16 HS System contains the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex-determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E.

View Article and Find Full Text PDF