Purpose: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients.
Methods: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®.
Eur J Nucl Med Mol Imaging
August 2024
Purpose: This manuscript aims to provide a better understanding of methods and techniques with which one can better quantify the impact of image-guided surgical technologies.
Methods: A literature review was conducted with regard to economic and technical methods of medical device evaluation in various countries. Attention was focused on applications related to image-guided interventions that have enabled procedures to be performed in a minimally invasive manner, produced superior clinical outcomes, or have become standard of care.
Fluorescence-guided surgery (FGS) is poised to revolutionize surgical medicine through near-infrared (NIR) fluorophores for tissue- and disease-specific contrast. Clinical open and laparoscopic FGS vision systems operate nearly exclusively at NIR wavelengths. However, tissue-specific NIR contrast agents compatible with clinically available imaging systems are lacking, leaving nerve tissue identification during prostatectomy a persistent challenge.
View Article and Find Full Text PDFBackground: Men with high-risk prostate cancer undergoing surgery likely recur due to failure to completely excise regional and/or local disease.
Objective: The first-in-human evaluation of safety, pharmacokinetics, and exploratory efficacy of IS-002, a novel near-infrared prostate-specific membrane antigen (PSMA)-targeted fluorescence imaging agent, designed for intraoperative prostate cancer visualization.
Design, Setting, And Participants: A phase 1, single-center, dose-escalation study was conducted in 24 men with high-risk prostate cancer scheduled for robotic-assisted radical prostatectomy with (extended) pelvic lymph node dissection using the da Vinci surgical system.
Patients undergoing gynecological procedures suffer from lasting side effects due to intraoperative nerve damage. Small, delicate nerves with complex and nonuniform branching patterns in the female pelvic neuroanatomy make nerve-sparing efforts during standard gynecological procedures such as hysterectomy, cystectomy, and colorectal cancer resection difficult, and thus many patients are left with incontinence and sexual dysfunction. Herein, a near-infrared (NIR) fluorescent nerve-specific contrast agent, LGW08-35, that is spectrally compatible with clinical fluorescence guided surgery (FGS) systems is formulated and characterized for rapid implementation for nerve-sparing gynecologic surgeries.
View Article and Find Full Text PDFSurgery is the preferred treatment option for most solid tumors. However, inaccurate detection of cancer borders leads to either incomplete removal of malignant cells or excess excision of healthy tissue. While fluorescent contrast agents and imaging systems improve tumor visualization, they can suffer from low signal-to-background and are prone to technical artifacts.
View Article and Find Full Text PDFBackground: Identifying ground glass opacities (GGOs) is challenging during robot-assisted thoracic surgery (RATS). Intraoperative molecular imaging (IMI) using tumor-targeted fluorescent tracers may address this clinical problem, but has never been evaluated in RATS. In a pilot study, we sought to determine whether IMI during RATS (RIMI) can localize GGOs.
View Article and Find Full Text PDFIatrogenic nerve injury significantly affects surgical outcomes. Although intraoperative neuromonitoring is utilized, nerve identification remains challenging and the success of nerve sparing is strongly correlated with surgeon experience levels. Fluorescence guided surgery (FGS) offers a potential solution for improved nerve sparing by providing direct visualization of nerve tissue intraoperatively.
View Article and Find Full Text PDFRobotic surgery bedside assistants play an important role in robotic procedures by performing intra-corporeal tasks while accommodating the physical presence of the robot. We hypothesized that an augmented reality headset enabling 3D intra-corporeal vision while facing the surgical field could decrease time and improve accuracy of robotic bedside tasks. Bedside assistants (one physician assistant, one medical student, three surgical trainees, and two attending surgeons) performed validated tasks within a mock abdominal cavity with a surgical robot docked.
View Article and Find Full Text PDFNerves are extremely difficult to identify and are often accidently damaged during surgery, leaving patients with lasting pain and numbness. Herein, a novel near-infrared (NIR) nerve-specific fluorophore, LGW01-08, was utilized for enhanced nerve identification using fluorescence guided surgery (FGS), formulated using clinical translatable strategies. Formulated LGW01-08 was examined for toxicology, pharmacokinetics (PK), and pharmacodynamics (PD) parameters in preparation for future clinical translation.
View Article and Find Full Text PDFOpt Mol Probes Imaging Drug Deliv
April 2021
Nerve damage is a major complication of surgery, causing pain and loss of function. We have identified novel near-infrared nerve-specific fluorophores that provide excellent nerve contrast with the ability to identify buried nerve tissue.
View Article and Find Full Text PDFSurgical resection of tumours requires precisely locating and defining the margins between lesions and normal tissue. However, this is made difficult by irregular margin borders. Although molecularly targeted optical contrast agents can be used to define tumour margins during surgery in real time, the selectivity of the contrast agents is often limited by the target being expressed in both healthy and tumour tissues.
View Article and Find Full Text PDFNerve-binding fluorophores with near-infrared (NIR; 650 to 900 nm) emission could reduce iatrogenic nerve injury rates by providing surgeons precise, real-time visualization of the peripheral nervous system. Unfortunately, current systemically administered nerve contrast agents predominantly emit at visible wavelengths and show nonspecific uptake in surrounding tissues such as adipose, muscle, and facia, thus limiting detection to surgically exposed surface-level nerves. Here, a focused NIR fluorophore library was synthesized and screened through multi-tiered optical and pharmacological assays to identify nerve-binding fluorophore candidates for clinical translation.
View Article and Find Full Text PDFWith the advent of precision surgery, there have been attempts to integrate imaging with robotic systems to guide sound oncologic surgical resections while preserving critical structures. In the confined space of transoral robotic surgery (TORS), this offers great potential given the proximity of structures. In this cadaveric experiment, we describe the use of a 3D virtual model displayed in the surgeon's console with the surgical field in view, to facilitate image-guided surgery at the oropharynx where there is significant soft tissue deformation.
View Article and Find Full Text PDFThe fluorescent imaging agent IS-001 was determined to be well tolerated in all subjects and has the potential to provide ureter visualization throughout minimally invasive hysterectomy procedures. This study was conducted to evaluate clinical safety and efficacy of a real-time ureter visualization technique for use during hysterectomy surgery. The study drug appears safe, is renally excreted, and allows enhanced ureter visualization when imaged with a clinically approved near-infrared sensitive endoscope.
View Article and Find Full Text PDFTumor removal typically involves electrocautery, but no studies to date have quantified the effect of electrocautery on fluorescence emission. Electrocautery was applied to N=4 locations of the oral cavity and striated leg muscle of a live Yorkshire pig. Autofluorescence of cauterized tissues and surrounding regions was measured at distinct time points up to 120 minutes following cauterization.
View Article and Find Full Text PDFMolecularly targeted optical contrast agents have the potential to enable surgeons to visualize specific molecular markers that can help improve surgical precision and thus outcomes. Fluorescently quenched substrates can be used to highlight tumor lesions by targeting proteases that are highly abundant in the tumor microenvironment. However, the majority of these and other molecularly targeted optical contrast agents are labeled with reporter dyes that are not ideally matched to the properties of clinical camera systems, which are typically optimized for detection of indocyanine-green (ICG).
View Article and Find Full Text PDFConsiderable advances in cancer-specific optical imaging have improved the precision of tumor resection. In comparison to traditional imaging modalities, this technology is unique in its ability to provide real-time feedback to the operating surgeon. Given the significant clinical implications of optical imaging, there is an urgent need to standardize surgical navigation tools and contrast agents to facilitate swift regulatory approval.
View Article and Find Full Text PDFIn transoral robotic surgery preoperative image data do not reflect large deformations of the operative workspace from perioperative setup. To address this challenge, in this study we explore image guidance with cone beam computed tomographic angiography to guide the dissection of critical vascular landmarks and resection of base-of-tongue neoplasms with adequate margins for transoral robotic surgery. We identify critical vascular landmarks from perioperative c-arm imaging to augment the stereoscopic view of a da Vinci si robot in addition to incorporating visual feedback from relative tool positions.
View Article and Find Full Text PDFInability to integrate surgical navigation systems into current surgical robot is one of the reasons for the lack of development of robotic endoscopic skull base surgery. We describe an experiment to adapt current technologies for real-time navigation during transoral robotic nasopharyngectomy. A cone-beam CT was performed with a robotic C-arm after the injecting contrast into common carotid artery.
View Article and Find Full Text PDFThere is a need for new molecular-guided contrast agents to enhance surgical procedures such as tumor resection that require a high degree of precision. Cysteine cathepsins are highly up-regulated in a wide variety of cancers, both in tumor cells and in the tumor-supporting cells of the surrounding stroma. Therefore, tools that can be used to dynamically monitor their activity in vivo could be used as imaging contrast agents for intraoperative fluorescence image guided surgery (FGS).
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
August 2015
Purpose: C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D-3D registration is needed for intra-procedural guidance.
View Article and Find Full Text PDFBackground: Adequate resection of oropharyngeal neoplasms with transoral robotic surgery (TORS) poses multiple challenges, including difficulty with access, inability to palpate the tumor, loss of landmarks, and intraoperative patient positioning with mouth retractor and tongue extended creating significant tissue distortion from preoperative imaging.
Methods: This study evaluates a workflow integrating intraoperative cone beam computed tomography (CBCT) for image-guided TORS through robotic experimentation locating 8-10 embedded targets in five porcine tongues and a cadaveric head phantom, conducted under various modes of visualization and integration of preoperative/intraoperative imaging.
Results: A statistically significant improvement in mean target localization error was achieved for both the porcine tongue ((9.
Importance: To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality.
Objective: To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion.