Publications by authors named "Jonathan Poli"

Neurophysiological brain activity underpins cognitive functions and behavioural traits. Here, we sought to establish to what extent individual neurophysiological traits spontaneously expressed in ongoing brain activity are primarily driven by genetic variation. We also investigated whether changes in such neurophysiological features observed across the lifespan are supported by longitudinal changes in cortical gene expression.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated how effectively different aerosol delivery systems (aerosol adapter vs. aerosol circuit) deliver bronchodilators through high-flow nasal cannula (HFNC) across neonatal, pediatric, and adult models.
  • Inhaled lung doses varied by age group, with adults receiving the highest doses, while neonates showed similar results between systems, but the aerosol circuit was slightly better for older children and adults.
  • The findings highlight that current aerosol delivery methods have low lung doses (1-5%) and suggest a need for improved systems to enhance treatment efficacy for patients on HFNC.*
View Article and Find Full Text PDF

Electrolyzed-reduced water has powerful antioxidant properties with constituents that scavenge reactive oxygen species (ROS), which are known to be produced by several intrinsic and extrinsic processes. When there is an imbalance between ROS production and antioxidant defenses, oxidative stress occurs. Persistent oxidative stress leads to cellular senescence, an important hallmark of aging, and is involved in several age-related conditions and illnesses.

View Article and Find Full Text PDF

The COVID-19 pandemic has brought attention to the need for developing effective respiratory support that can be rapidly implemented during critical surge capacity scenarios in healthcare settings. Lung support with bubble continuous positive airway pressure (B-CPAP) is a well-established therapeutic approach for supporting neonatal patients. However, the effectiveness of B-CPAP in larger pediatric and adult patients has not been addressed.

View Article and Find Full Text PDF

Surfactant administration incorporates liquid bolus instillation via endotracheal tube catheter and use of a mechanical ventilator. Aerosolized surfactant has generated interest and conflicting data related to dose requirements and efficacy. We hypothesized that aerosolized surfactant with a novel breath-actuated vibrating mesh nebulizer would have similar efficacy and safety as instilled surfactant.

View Article and Find Full Text PDF

Despite its established safety, efficacy, and relative simplicity, CPAP treatment is not widely available for newborns and infants in low- and middle-income settings. A novel bubble CPAP system was designed to address the gaps in quality and accessibility of existing CPAP systems by providing blended, humidified, and pressurized gases without the need for electricity, compressed air, or manual power. This was the first study that tested the performance of the system with a simulated patient model.

View Article and Find Full Text PDF

Objectives: Effective treatment options for surfactant therapy in acute respiratory distress syndrome and coronavirus disease 2019 have not been established. To conduct preclinical studies in vitro and in vivo to evaluate efficiency, particle size, dosing, safety, and efficacy of inhaled surfactant using a breath-synchronized, nebulized delivery system in an established acute respiratory distress syndrome model.

Design: Preclinical study.

View Article and Find Full Text PDF

Background: Different brands of volume-targeted modes may vary the location of tidal volume (V) monitoring and whether peak inspiratory pressure is adjusted based on inspiratory, expiratory or leak-compensated V. These variables may result in different levels of support provided to patients, especially when an endotracheal tube (ETT) leak is present. We hypothesized that there would be no differences in gas exchange, triggering, or work of breathing between volume-targeted modes of 3 different brands of equipment in a surfactant-deficient, spontaneously breathing animal model with and without an ETT leak.

View Article and Find Full Text PDF

Introduction: This study was designed to evaluate short-term physiologic outcomes of transitioning neonates with bronchopulmonary dysplasia (BPD) from intensive care unit (ICU) ventilators to both the Trilogy 202 (Philips Healthcare, Andover, MA) and LTV 1200 (CareFusion, Yorba Linda, CA) subacute ventilators.

Methods: Six infants with BPD requiring tracheostomies for support with a neonatal-specific ICU ventilator underwent placement of esophageal balloon catheters, airway pressure transducers, flow sensors, oxygen saturation (SpO), and end tidal carbon dioxide (PCO) monitors. Noninvasive gas exchange, airflow, and airway and esophageal pressures (P) were recorded following 20 min on the ICU ventilator.

View Article and Find Full Text PDF

Background: High-frequency pressure oscillations created by gas bubbling through an underwater seal during bubble CPAP may enhance ventilation and aid in lung recruitment in premature infants. We hypothesized that there are no differences in the magnitude of oscillations in lung volume (ΔV) in a preterm neonatal lung model when different bubble CPAP systems are used.

Methods: An anatomically realistic replica of an infant nasal airway model was attached to a Silastic test lung sealed within a calibrated plethysmograph.

View Article and Find Full Text PDF