A retrospective analysis of endovenous glue-closure therapy (EVGC) performed in 76 greater saphenous veins (GSVs) from February 2016 to December 2017 was conducted to assess the incidence and characteristics of endovenous glue-induced thrombosis (EGIT), a phenomenon unique to nonthermal EVGC for GSV insufficiency. Kabnick and Lawrence classifications for endovenous heat-induced thrombosis were adopted. Seven instances of EGIT were detected among 54 patients (13%), with median/mode Kabnick and Lawrence classifications of 2/2 and 4/5, respectively.
View Article and Find Full Text PDFA hybrid of radiotherapy and photodynamic therapy (PDT) has been proposed in previously reported studies. This approach utilizes scintillating nanoparticles to transfer energy to attached photosensitizers, thus generating singlet oxygen for local killing of malignant cells. Its effectiveness strongly depends upon the scintillation yield of the nanoparticles.
View Article and Find Full Text PDFEndovascular techniques for the treatment of peripheral arterial disease are becoming an increasingly common alternative to open surgery, yet the degree of anticoagulation and choice of anticoagulant to optimize outcomes in these procedures remain uncertain. To date, few randomized trials have directly compared different anticoagulants for use during peripheral vascular interventions. It is also unclear if the approach to anticoagulation should be individualized to each vascular bed or if common principles are shared among them.
View Article and Find Full Text PDFPurpose: Spatially fractionated GRID radiotherapy (SFGRT) using a customized Cerrobend block has been used to improve response rates in patients with bulky tumors. The clinical efficacy of our own multileaf collimator (MLC) technique is unknown. We undertook a retrospective analysis to compare clinical response rates attained using these two techniques.
View Article and Find Full Text PDFPurpose: To retrospectively determine the frequency and importance of a small amount of isolated pelvic free fluid seen at multidetector computed tomography (CT) in male patients who have blunt trauma without an identifiable cause.
Materials And Methods: Institutional review board approval was obtained, and the requirement for informed consent was waived for this HIPAA-compliant study. One thousand male patients with blunt trauma who underwent abdominopelvic CT at a level 1 trauma center between January 2004 and June 2006 were entered into this study.
Background: The analysis of pelvic CT scans is a crucial step for detecting and assessing the severity of Traumatic Pelvic Injuries. Automating the processing of pelvic CT scans could impact decision accuracy, decrease the time for decision making, and reduce health care cost. This paper discusses a method to automate the segmentation of bone from pelvic CT images.
View Article and Find Full Text PDFClinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinical outcome. Using a kernel-based Monte Carlo dose engine that incorporates phantom motion, we calculate the dose distributions for a GRID with hexagonally arranged holes.
View Article and Find Full Text PDFA systematic study on the sources of drift in a turbine-based spirometer (VMM-400) is presented. The study utilized an air-tight cylinder to pump air through the spirometer in a precise and programmable manner. Factors contributing to the drift were isolated and quantified.
View Article and Find Full Text PDFThe feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mm x 10 mm and 5 mm x 5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations.
View Article and Find Full Text PDF