Background: Transverse process fractures (TPF) of the thoracic and lumbar spine have become increasingly identified due to CT imaging. Spine service consultation is common for further evaluation and management. There are several studies that demonstrate no difference in clinical outcome with or without spine service intervention.
View Article and Find Full Text PDFMetal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric wear rate for a MoM bearings was lower than its polyethylene counterpart, metal ion particles were found to be approximately 10 × smaller and 500 × higher in quantity compared to polyethylene wear debris. Research into these articulations have demonstrated their relationship to the formation of lymphocyte-mediated adverse local tissue reactions.
View Article and Find Full Text PDFJ Neurosurg Case Lessons
May 2021
Background: Management of gunshot wounds to the spine with subsequent spinal cord injury is a controversial topic among spine surgeons. Possible complications of retained intradural bullets include delayed neurological deficits, spinal instability, and lead toxicity. The authors' purpose is to review the potential complications of retained intraspinal bullets and the surgical indications for intraspinal bullet removal.
View Article and Find Full Text PDFObjectives: To evaluate a large series of open fractures of the forearm after gunshot wounds (GSWs) to determine complication rates and factors that may lead to infection, nonunion, or compartment syndrome.
Design: Multicenter retrospective review.
Setting: Nine Level 1 Trauma Centers.
Twenty-five patients undergoing simultaneous, bilateral total knee arthroplasty (TKA) were randomized to receive skin closure with Zip device on one knee and staples on the other. Patients' pain and scar appearance were rated from 0 (best) to 10 (worst). Knee arc of motion was measured by a physical therapist.
View Article and Find Full Text PDFBackground: Augmented reality (AR) has the potential to be utilized in various fields. Nursing fulfils the requirements of smart glass use cases, and technology may be one method of supporting nurses that face challenges such as demographic change. The development of AR to assist in nursing is now feasible.
View Article and Find Full Text PDFStud Health Technol Inform
November 2018
Smart Glasses are a promising technology that can be leveraged to improve flexible service processes. Especially in the field of nursing where practitioners are facing complex tasks and challenges. Introducing such pervasive computing devices in service processes may have both positive and negative consequences.
View Article and Find Full Text PDF