Background: Glycerol is a substrate for gluconeogenesis and fatty acid esterification in the liver, processes which are upregulated in obesity and may contribute to excess fat accumulation. Glycine and glutamate, in addition to cysteine, are components of glutathione, the major antioxidant in the liver. In principle, glycerol could be incorporated into glutathione via the TCA cycle or 3-phosphoglycerate, but it is unknown whether glycerol contributes to hepatic de novo glutathione biosynthesis.
View Article and Find Full Text PDFIntroduction: Use of sleeve gastrectomy (SG) for weight loss has grown exponentially; however, clear indications for SG versus Roux-en-Y gastric bypass (RNYGB) are lacking. Certain populations may be more likely to undergo SG due to its simpler technique and without clear clinical indications. We aim to examine underlying predictors of patients undergoing SG vs RNY across a single state.
View Article and Find Full Text PDFBackground: Morbid obesity is associated with an increased risk of thrombotic events, which has been attributed to increased thrombotic activity. Multiple mechanisms have been proposed to explain this increased risk, including an inflammatory state with upregulation of procoagulant and antifibrinolytic proteins. We therefore hypothesize that patients with morbid obesity are hypercoagulable and will revert to normal after bariatric surgery.
View Article and Find Full Text PDFBariatric surgery is associated with significant and sustained weight loss and improved metabolic outcomes. It is unclear if weight loss alone is the main mechanism of improved metabolic health. The purpose of this trial was to compare indices of appetite regulation, insulin sensitivity and energy intake (EI) between participants achieving 10 kg of weight loss via Roux-en-Y Gastric Bypass (RYGB) or dietary restriction (DIET); intake of a very low calorie liquid diet (800 kcal/d; 40% protein, 40% fat, 20% carbohydrate that matched the post-RYGB dietary protocol).
View Article and Find Full Text PDFIntermuscular adipose tissue (IMAT) is negatively related to insulin sensitivity, but a causal role of IMAT in the development of insulin resistance is unknown. IMAT was sampled in humans to test for the ability to induce insulin resistance in vitro and characterize gene expression to uncover how IMAT may promote skeletal muscle insulin resistance. Human primary muscle cells were incubated with conditioned media from IMAT, visceral (VAT), or subcutaneous adipose tissue (SAT) to evaluate changes in insulin sensitivity.
View Article and Find Full Text PDFThe objective of this study was to determine the pharmacokinetics and pharmacodynamics (PK/PD) of a weight-based cefoxitin dosing regimen for surgical prophylaxis in obese patients. Patients received a single dose of cefoxitin at 40 mg/kg based on total body weight. Cefoxitin samples were obtained over 3 h from serum and adipose tissue, and concentrations were determined by validated high-performance liquid chromatography.
View Article and Find Full Text PDFGoal: Development of a new medical device class generally termed robotic capsule endoscopes (RCE) is currently being pursued by multiple research groups. These maneuverable devices will allow minimally invasive diagnosis and treatment of intestinal pathologies. While the intraluminal pressures related to the migrating motor complex (MMC) are well understood, no previous study has measured the active contact forces exerted by the human small bowel wall on a solid, or near solid bolus such as an RCE.
View Article and Find Full Text PDFBackground: Laparoscopic sleeve gastrectomy (LSG) has become an increasingly popular stand-alone weight loss surgery, but there is a paucity of long-term efficacy data.
Objective: To determine long-term outcomes for patients undergoing LSG.
Setting: Tertiary care university hospital in the United States.
Introduction: Harvested biological tissue is a common medium for surgical device assessment in a laboratory setting; this study aims to differentiate between surgical device performance in the clinical and laboratory environments prior to and following tissue storage. Vascular tissue fusion devices are sensitive to tissue-device temperature gradients, tissue pre-stretch in vivo and tissue water content, each of which can vary during tissue storage. In this study, we compare the results of tissue fusion prior to and following storage using a standardized bursting pressure protocol.
View Article and Find Full Text PDFBackground: Patients with Medicaid are much less likely to undergo bariatric surgery compared to those with commercial insurance. The aims of this study were to compare outcomes after laparoscopic Roux-en-Y gastric bypass (LRYGB) for patients covered by Medicaid, other (non-Medicaid) government insurance, and commercial insurance.
Methods: This was a retrospective cohort study of all eligible patients who underwent LRYGB between July 2004 and October 2011 at a single university hospital (n = 450).
Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs.
View Article and Find Full Text PDFIn an open surgery, identification of precise margins for curative tissue resection is performed by manual palpation. This is not the case for minimally invasive and robotic procedures, where tactile feedback is either distorted or not available. In this paper, we introduce the concept of intraoperative wireless tissue palpation.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
April 2013
Viscoelastic models are generally considered a good option for modeling biological tissue due to tissue time-dependency. However, although various forms of viscoelastic models have been developed, only a few have shown a good balance between model mathematical simplicity and experimental fit accuracy. Starting from a basic Standard Linear Solid (SLS) model, a systematic modification of the viscoelastic model leading to a more accurate tissue model is presented.
View Article and Find Full Text PDFThe development of robotic capsule endoscopes (RCEs) is one avenue presently investigated by multiple research groups to minimize invasiveness and enhance outcomes of enteroscopic procedures. Understanding the biomechanical response of the small bowel to RCEs is needed for design optimization of these devices. In previous work, the authors developed, characterized, and tested the migrating motor complex force sensor (MFS), a novel sensor for quantifying the contact forces per unit of axial length exerted by the myenteron on a solid bolus.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
November 2012
Multiple research groups are investigating the feasibility of miniature, swallowable, in vivo, untethered robots that are capable of traversing the small intestine for the purpose of acquiring biometrics and performing simple surgical procedures. A mathematical model of the intraluminal environment will speed the development of these so-called Robotic Capsule Endoscopes (RCEs), and to this end, the authors, in previous work, initiated a comprehensive program for characterizing both the active and passive forces exerted by the small intestine on an RCE-sized solid bolus. In this work, forces due to adhesivity between RCE materials and the mucosa are investigated.
View Article and Find Full Text PDFBackground: The state-of-the-art technology for gastrointestinal (GI) tract exploration is a capsule endoscope (CE). Capsule endoscopes are pill-sized devices that provide visual feedback of the GI tract as they move passively through the patient. These passive devices could benefit from a mobility system enabling maneuverability and controllability.
View Article and Find Full Text PDFThe intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine.
View Article and Find Full Text PDFIn this paper, we designed, built, and tested a novel single-port access laparoscopic surgery (SPA) specific camera system. This device (magnet camera) integrates a light source and video camera into a small, inexpensive, portable package that does not compete for space with the surgical tools during SPA. The device is inserted through a 26-mm incision in the umbilicus, followed by the SPA port, which is used to maintain an insufflation seal and support the insertion of additional tools.
View Article and Find Full Text PDFIn this work we present test methods, devices, and preliminary results for the mechanical characterization of the small bowel for intra luminal robotic mobility. Both active and passive forces that affect mobility are investigated. Four investigative devices and testing methods to characterize the active and passive forces are presented in this work: (1) a novel manometer and a force sensor array that measure force per cm of axial length generated by the migrating motor complex, (2) a biaxial test apparatus and method for characterizing the biomechanical properties of the duodenum, jejunum, and ileum, (3) a novel in vitro device and protocol designed to measure the energy required to overcome the self-adhesivity of the mucosa, and (4) a novel tribometer that measures the in vivo coefficient of friction between the mucus membrane and the robot surface.
View Article and Find Full Text PDFIn this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD).
View Article and Find Full Text PDF