Objective: While meniscal repair is preferable to meniscectomy, some cases may be at higher risk of failure if repaired. Incorporating fibrin clot (FC) into the repair has been proposed to improve healing rates. The purpose of this study was to determine the failure rates, patient reported outcome measures (PROMs) and complications of FC augmented meniscal repair for cases considered to be at higher risk of failure.
View Article and Find Full Text PDFIntroduction: Fenestrated endovascular aneurysm repair (FEVAR) is the highest radiation dose procedure performed by vascular surgeons. We sought to characterize the radiation dose to patients and staff during FEVAR procedures with different premanufactured devices.
Methods: A single-center prospective study of FEVARs was performed over 24 months.
Objective: Radiation to the interventionalist's brain during fluoroscopically guided interventions (FGIs) may increase the incidence of cerebral neoplasms. Lead equivalent surgical caps claim to reduce radiation brain doses by 50% to 95%. We sought to determine the efficacy of the RADPAD (Worldwide Innovations & Technologies, Lenexa, Kan) No Brainer surgical cap (0.
View Article and Find Full Text PDFBackground: A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system.
Methods: Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity.
Purpose: To study the feasibility of using an iterative reconstruction algorithm to improve previously reconstructed CT images which are judged to be non-diagnostic on clinical review. A novel rapidly converging, iterative algorithm (RSEMD) to reduce noise as compared with standard filtered back-projection algorithm has been developed.
Materials And Methods: The RSEMD method was tested on in-silico, Catphan(®)500, and anthropomorphic 4D XCAT phantoms.
Background: Surgeon radiation dose during complex fluoroscopically guided interventions (FGIs) has not been well studied. We sought to characterize radiation exposure to surgeons during FGIs based on procedure type, operator position, level of operator training, upper vs lower body exposure, and addition of protective shielding.
Methods: Optically stimulable, luminescent nanoDot (Landauer, Inc, Glenwood, Ill) detectors were used to measure radiation dose prospectively to surgeons during FGIs.
Background: Endovascular aortic aneurysm repairs (EVARs) with fenestrated (FEVAR) stent grafts are high radiation dose cases, yet no skin injuries were found retrospectively in our 61 cases with a mean peak skin dose (PSD) of 6.8 Gy. We hypothesize that skin injury is under-reported.
View Article and Find Full Text PDFCurr Probl Diagn Radiol
September 2015
Fluoroscopically guided procedures are an area of radiology in which radiation exposure to the patient is highly operator dependent. Modern fluoroscopy machines display a variety of information, including technique factors, field of view, operating geometry, exposure mode, fluoroscopic time, air kerma at the reference point (RAK), and air kerma area-product. However, the presentation of this information is highly vendor specific, and many users are unaware of how to interpret this information and use it to perform a study with the minimum necessary dose.
View Article and Find Full Text PDFBackground: Radiation-induced skin injury is a serious potential complication of fluoroscopically guided interventions. Transient erythema occurs at doses of 2 to 5 Gy, whereas permanent epilation, ulceration, and desquamation are expected at doses above this level. Complex endovascular procedures (CEPs), such as fenestrated endovascular aortic aneurysm repair (FEVAR), are associated with high radiation doses, yet the prevalence of radiation-induced skin injury is unknown.
View Article and Find Full Text PDFObjective: Complex endovascular procedures such as fenestrated endovascular aneurysm repair (FEVAR) are associated with higher radiation doses compared with other fluoroscopically guided interventions (FGIs). The purpose of this study was to determine whether surgeon education on radiation dose control can lead to lower reference air kerma (RAK) and peak skin dose (PSD) levels in high-dose procedures.
Methods: Radiation dose and operating factors were recorded for FGI performed in a hybrid room over a 16-month period.
Computed tomographic (CT) scanning technology now employs up to 320 detector rows of 0.5-mm width and allows rapid acquisition of isotropic volume datasets over the entire body. Data from a single CT acquisition can be reconstructed into image series that would formerly have required multiple acquisitions.
View Article and Find Full Text PDFThe shielding of positron emission tomography (PET) and PET/CT (computed tomography) facilities presents special challenges. The 0.511 MeV annihilation photons associated with positron decay are much higher energy than other diagnostic radiations.
View Article and Find Full Text PDF