Publications by authors named "John Triano"

Background: Cervical spine manipulation (CSM) is a frequently used treatment for neck pain. Despite its demonstrated efficacy, concerns regarding the potential of stretch damage to vertebral arteries (VA) during CSM remain. The purpose of this study was to quantify the angular displacements of the head relative to the sternum and the associated VA length changes during the thrust phase of CSM.

View Article and Find Full Text PDF

Background: The inflammatory profiles of patients with acute and chronic nonspecific low back pain (LBP) patients are distinct. Spinal manipulative therapy (SMT) has been shown to modulate the production of nociceptive chemokines differently in these patient cohorts. The present study further investigates the effect(s) of SMT on other inflammatory mediators in the same LBP patient cohorts.

View Article and Find Full Text PDF

Background: Regional interdependence is conceptually based on observations that applying manual therapy to a remote anatomical region has an effect in the area of the patient's primary complaint. The current model for regional interdependence depends on force transmissibility within the body. This investigation sought to determine transmissibility between forces applied to the thoracic spine during prone-lying high-velocity low-amplitude spinal manipulative therapy and the cervical spine.

View Article and Find Full Text PDF

Background: The pathogenesis of low back pain (LBP) remains unclear. However, recent studies suggest that the inflammatory response may be inherent in spinal pain. The purpose of this study was to discern inflammatory profiles in patients with nonspecific acute and chronic LBP in relation to those in asymptomatic individuals.

View Article and Find Full Text PDF

Objective: It is hypothesised that cervical manipulation may increase the risk of cerebrovascular accidents. We aimed to determine whether cervical spine manipulation is associated with changes in vertebral artery and cerebrovascular haemodynamics measured with MRI compared with neutral neck position and maximum neck rotation in patients with chronic neck pain.

Setting: The Imaging Research Centre at St.

View Article and Find Full Text PDF

Background: The involvement of inflammatory components in the pathophysiology of low back pain (LBP) is poorly understood. It has been suggested that spinal manipulative therapy (SMT) may exert anti-inflammatory effects.

Purpose: The purpose of this study was to determine the involvement of inflammation-associated chemokines (CC series) in the pathogenesis of nonspecific LBP and to evaluate the effect of SMT on that process.

View Article and Find Full Text PDF

Objective: The aim of this preliminary study was to determine the differences in abdominal musculature thickness, within 1 month of delivery, in women who experienced back pain during pregnancy compared with those who did not.

Methods: B-mode ultrasound imaging was used to measure abdominal muscle thickness on 76 postpartum participants who participated in a larger study; 47 women experienced back pain during pregnancy, and 29 did not. Participant data were stratified by group, and primary comparisons were based on these grouping across the abdominal muscles, including rectus abdominis (upper and lower fibers), external oblique, internal oblique, and transversus abdominis.

View Article and Find Full Text PDF

Objective: The purpose of this work was to create an exploratory database of manipulation treatment force variability as a function of the intent of an experienced clinician sub-specializing in the care of children to match treatment to childhood category. Data of this type are necessary for realistic planning of dose-response and safety studies on therapeutic benefit.

Methods: The project evaluated the transmitted peak forces of procedures applied to mannequins of different stature for younger and older children.

View Article and Find Full Text PDF

Objectives: This investigation compared indirect 3-dimensional angular kinematics (position, velocity, and acceleration) of the lumbar spine for 2 different high-velocity, low-amplitude (HVLA) spinal manipulation procedures (lumbar spinous pull or push), and altered initial patient lower limb posture.

Methods: Twenty-four participants underwent 6 HVLA procedures directed toward the presumed L4 vertebra, reflecting each combination of 2 variants of a spinal manipulation application technique (spinous pull and push) and 3 initial hip flexion angles (0°, 45°, and 90°) applied using a right lateral recumbent patient position. All contact forces and moments between the patient and the external environment, as well as 3-dimensional kinematics of the patient's pelvis and thorax, were recorded.

View Article and Find Full Text PDF

Objective: The use of chiropractic services has stalled while interest in accessing manipulation services is rising. The purpose of this paper is to consider this dilemma in the context of the dynamics of professional socialization, surveys of public attitudes, and a potential strategic action.

Discussion: This is a reflection work grounded in the literature on professional socialization and the attitudes held regarding chiropractic in modern society, to include its members, and in original data on training programs.

View Article and Find Full Text PDF

Study Design: An in vivo biomechanical study.

Objective: The aim of the present study was to quantify and compare the reaction loads for two spinal manipulation therapy (SMT) procedures commonly used for low back pain using a biomechanical computer model.

Summary Of Background Data: Contemporary computer-driven rigid linked-segment models (LSMs) have made it feasible to analyze low back kinetics and kinematics during various activities including SMT procedures.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how axial rotation of the torso during manipulation treatment affects the morphology of spinal discs, specifically analyzing disc height distribution in both neutral and rotated positions.
  • Eighty-one volunteers underwent CT scans, allowing researchers to model intervertebral gaps and measure disc height across various anatomical zones, revealing changes when the torso is rotated 50°.
  • Results showed a significant increase in overall disc height when rotated, particularly on the right side, while the implications of these changes on spine manipulation remain unclear.
View Article and Find Full Text PDF

Objective: The purpose of this paper is to present the experimental setup, the development, and implementation of a new scalable model capable of efficiently handling data required to determine low back kinetics during high-velocity low-amplitude spinal manipulation (HVLA-SM).

Methods: The model was implemented in Visual3D software. All contact forces and moments between the patient and the external environment (2 clinician hand contact forces, 1 contact force between the patient and the treatment table), the patient upper body kinematics, and inertial properties were used as input.

View Article and Find Full Text PDF

Background: Understanding the biomechanics of spinal manipulative therapy requires knowing how loads are transmitted to deeper structures. This investigation monitored displacement at sequential depths in thoracic paraspinal tissues parallel with surface load directions.

Methods: Participants were prone and a typical preload maneuver was applied to thoracic tissues.

View Article and Find Full Text PDF

Objective: The purpose of this study is to evaluate the effect of treatment with a novel noninvasive interactive neurostimulation device (InterX5000) on the production of inflammatory biomarkers in chronic and recurrent mechanical neck pain (NP) syndrome.

Methods: This study represents pilot biological data from a randomized controlled clinical trial. Twenty-five NP patients and 14 asymptomatic subjects included for baseline comparison only completed the study.

View Article and Find Full Text PDF

Objective: The purpose of this study was to sample the stability of spinal manipulation performance in peak impulse force development over time and the ability of clinicians to adapt to arbitrary target levels with short-duration training.

Methods: A pre-post experimental design was used. Human analog mannequins provided standardized simulation for performance measures.

View Article and Find Full Text PDF

Objective: The purpose of this study was to determine the effect size in measurable change of abdominal musculature morphology using ultrasonography in postpartum women within 1 month of a healthy, vaginal delivery.

Methods: One hundred fifty-six participants were recruited for this study. B-mode ultrasound imaging was used to measure abdominal muscle thickness on 80 nulliparous women and 76 mothers who had delivered within the past 4 weeks.

View Article and Find Full Text PDF

Across the foot sole, there are vibration and monofilament sensory differences despite an alleged even distribution of cutaneous afferents. Mechanical property differences across foot sole sites have been proposed to account for these differences. Vibration (VPT; 3 Hz, 40 Hz, 250 Hz), and monofilament (MF) perception threshold measurements were compared with skin hardness, epidermal thickness, and stretch response across five foot sole locations in young healthy adults (n = 22).

View Article and Find Full Text PDF

Background: Spontaneous vertebral artery dissection has significant mortality and morbidity among young adults. Unfortunately, causal mechanisms remain unclear. The purpose of this study was to quantify mechanical strain in the vertebral artery while simultaneously capturing motion analysis data during passive movements of the head and neck relative to the trunk during spinal manipulation and cardinal planes of motion.

View Article and Find Full Text PDF

The study was conducted to estimate the extent to which pressure pain sensitivity (PPS) and patient factors predict pain-related disability in patients with neck pain (NP), and to determine if PPS differs by gender. Forty-four participants with a moderate level of chronic NP were recruited for this cross sectional study. All participants were asked to complete self-reported assessments of pain, disability and comorbidity and then underwent PPS testing at 4-selected body locations.

View Article and Find Full Text PDF

Study Design: In vivo 3-dimensional (3D) morphometric analysis of the lumbar foramen by using 3D computed tomographic models in normal subjects.

Objective: To describe foraminal geometry in an asymptomatic cohort measured in 3D.

Summary Of Background Data: Appropriate assessment of the complex 3D lumbar foraminal geometry is key to correct radiculopathy diagnosis and treatment planning.

View Article and Find Full Text PDF

Skill development in manual therapies is influenced by a number of factors. The effects of the training program organization, mentor coaching, feedback in various forms, and electromechanical training aids are factors that have been studied. A significant gap exists in understanding when teaching aids might be most effective within a defined curriculum structure.

View Article and Find Full Text PDF

Background: With the development of increasing evidence for the use of manipulation in the management of musculoskeletal conditions, there is growing interest in identifying the appropriate indications for care. Recently, attempts have been made to develop clinical prediction rules, however the validity of these clinical prediction rules remains unclear and their impact on care delivery has yet to be established. The current study was designed to evaluate the literature on the validity and reliability of the more common methods used by doctors of chiropractic to inform the choice of the site at which to apply spinal manipulation.

View Article and Find Full Text PDF

Objective: The objective of the study was to investigate the cerebrovascular hemodynamic response of cervical spine positions including rotation and cervical spine manipulation in vivo using magnetic resonance imaging technology on the vertebral artery (VA).

Methods: This pilot study was conducted as a blinded examiner cohort with 4 randomized clinical tasks. Ten healthy male participants aged 24 to 30 years (mean, 26.

View Article and Find Full Text PDF

Objective: Participants in clinical trials of spinal manipulation have not been rigorously blinded to group assignment. This study reports on secondary analyses of the retention of participant blinding beyond the immediate posttreatment time frame following a single-session, randomized clinical study. A novel control cervical manipulation procedure that has previously been shown to be therapeutically inert was contrasted with a typical manipulation procedure.

View Article and Find Full Text PDF