Publications by authors named "John Ransom"

In this pilot safety study, we hypothesized that a human bone marrow stem cell-derived extracellular vesicle (hBM-MSC EV) investigational product (IP) would be safe and exhibit potential efficacy in amyotrophic lateral sclerosis (ALS) patients. Ten ALS patients received two 10-ml intravenous infusions of the IP given 1 month apart and evaluated over 3 months. There were no serious adverse events or adverse events related to the IP and 30% of subjects' ALS functional rating scale-revised (ALSFRS-R) scores did not decline.

View Article and Find Full Text PDF

Efficacy of mesenchymal stem cells (MSCs) for treatment of acute respiratory distress syndrome (ARDS) suggests bioactive bone marrow MSC extracellular vesicles (BM-MSC EVs) may be effective. A patient with severe COVID-19 associated ARDS who was presumed to expire was treated with a BM-MSC EV preparation (14 doses over two months) as a rescue treatment for refractory COVID ARDS. Near complete reversal of lung inflammation and fibrosis (per computed tomography), near complete restoration of mobility, hospital discharge (3 months) with resumption of normal activities of daily living (one year) and return to work occurred.

View Article and Find Full Text PDF

A 3-month pilot study to evaluate the safety of injecting a bone marrow-derived mesenchymal stem cell extracellular vesicle advanced investigational product (IP) into the lumbar facet joint space as a treatment for chronic low back pain. 20 healthy adults were treated with IP injections (0.5 ml/joint) and evaluated by three functional assessments 1, 3, 7, 14, 30, 60 and 90 days later.

View Article and Find Full Text PDF

Background: Complex regional pain syndrome (CRPS) is an extremely painful disorder driven primarily by inflammation.

Objectives: We hypothesized that the immunomodulatory biologic, ExoFloTM, composed of bone marrow mesenchymal stem cell-derived extracellular vesicles, could be safely administered to CRPS patients and alleviate symptoms.

Study Design: Ten patients received 2 intravenous (IV) infusions, each containing 15 mL ExoFlo, on day one and day 4.

View Article and Find Full Text PDF

Importance: Left ventricular assist devices (LVADs) enhance quality and duration of life in advanced heart failure. The burden of nonsurgical bleeding events is a leading morbidity. Aspirin as an antiplatelet agent is mandated along with vitamin K antagonists (VKAs) with continuous-flow LVADs without conclusive evidence of efficacy and safety.

View Article and Find Full Text PDF

Background: Bone marrow mesenchymal stem cell (BM-MSC)-derived extracellular vesicles (ExoFlo) convey the immunomodulatory and regenerative properties of intact BM-MSCs. This study aimed to determine the safety and efficacy of ExoFlo as treatment for moderate to severe ARDS in patients with severe COVID-19.

Research Question: Do two doses of ExoFlo safely reduce mortality in COVID-19-associated moderate to severe ARDS compared with placebo?

Study Design And Methods: A prospective phase 2 multicenter double-anonymized randomized placebo-controlled dosing trial was conducted at five sites across the United States with infusions of placebo, 10 mL of ExoFlo, or 15 mL of ExoFlo on days 1 and 4.

View Article and Find Full Text PDF

The purpose of this study was to describe the changes in plasma levels of angiogenic and inflammatory biomarkers, specifically Ang-2 and TNF-α, in patients receiving HeartMate II (HMII) left ventricular assist device (LVAD) and correlate them with nonsurgical bleeding. It has been shown that angiopoietin-2 (Ang-2) and tissue necrosis factor-α (TNF-α) may be linked to bleeding in LVAD patients. This study utilized biobanked samples prospectively collected from the PREVENT study, a prospective, multicenter, single-arm, nonrandomized study of patients implanted with HMII.

View Article and Find Full Text PDF

The aim of this investigation was to characterize the hemostatic status of heart failure patients with implanted left ventricular assist devices (LVADs) to propose a mechanism associated with bleeding. Patients (n = 300) from 23 US hospitals were enrolled in the PREVENtion of HeartMate II Pump Thrombosis through Clinical Management (PREVENT) study. A biobank was established with serum and plasma samples prospectively collected from a cohort of 175 patients preimplant baseline (BL) and 3 months (3M) postimplant.

View Article and Find Full Text PDF

Background: Heart failure disproportionately affects Black patients. Whether differences among race influence outcomes in advanced heart failure with use of a fully magnetically levitated continuous-flow left ventricular assist device remains uncertain.

Methods: We included 515 IDE (Investigational Device Exemption) clinical trial patients and 500 Continued Access Protocol patients implanted with the HeartMate 3 left ventricular assist device in the MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3).

View Article and Find Full Text PDF

Importance: Left ventricular assist devices (LVADs) are well established in the treatment of advanced heart failure, but it is unclear whether outcomes are different based on the intended goal of therapy in patients who are eligible vs ineligible for heart transplant.

Objective: To determine whether clinical outcomes in the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) trial differed by preoperative categories of bridge to transplant (BTT) or bridge to transplant candidacy (BTC) vs destination therapy (DT).

Design, Setting, And Participants: This study was a prespecified secondary analysis of the MOMENTUM 3 trial, a multicenter randomized clinical trial comparing the magnetically levitated centrifugal-flow HeartMate 3 (HM3) LVAD to the axial-flow HeartMate II (HMII) pump.

View Article and Find Full Text PDF

Background: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device.

Methods: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device.

View Article and Find Full Text PDF

The PREVENtion of HeartMate II pump Thrombosis through clinical management (PREVENT) study was a multicenter, prospective investigation to evaluate the rate of pump thrombosis (PT) with adoption of a uniform set of surgical and medical practices for left ventricular assist device implantation. We sought to quantify pump position at baseline and retrospectively define a pump position associated with poor clinical outcomes. Chest x-rays at baseline were prospectively obtained per protocol.

View Article and Find Full Text PDF

Background: Recommended structured clinical practices including implant technique, anti-coagulation strategy, and pump speed management (PREVENT [PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management] recommendations) were developed to address risk of early (<3 months) pump thrombosis (PT) risk with HeartMate II (HMII; St. Jude Medical, Inc. [Thoratec Corporation], Pleasanton, CA).

View Article and Find Full Text PDF

Background: Recent reports suggested that HeartMate II (HMII) thrombosis rates may be higher in implants after 2011. We characterize events at HMII centers (>100 HMII implants) whose device thrombosis rates are equivalent or lower than reported by INTERMACS.

Methods: Seven centers pooled implants from 2011 through June 2013 to examine pump thrombus and identify characteristics and clinical strategies that potentially mitigate the risk.

View Article and Find Full Text PDF

Current practice of autologous fat transfer for soft tissue augmentation is limited by poor long-term graft retention. Adipose-derived regenerative cells (ADRCs) contain several types of stem and regenerative cells, which may help improve graft retention through multiple mechanisms. Using a murine fat transplantation model, ADRCs were added to transplanted fat to test whether ADRCs could improve the long-term retention of the grafts.

View Article and Find Full Text PDF

's readers select some of biotech's most remarkable and influential personalities from the past 10 years.

View Article and Find Full Text PDF

HyperCyt, an automated sample handling system for flow cytometry that uses air bubbles to separate samples sequentially introduced from multiwell plates by an autosampler. In a previously documented HyperCyt configuration, air bubble separated compounds in one sample line and a continuous stream of cells in another are mixed in-line for serial flow cytometric cell response analysis. To expand capabilities for high-throughput bioactive compound screening, the authors investigated using this system configuration in combination with automated cell sorting.

View Article and Find Full Text PDF